Clinical Trial Summary

Transcatheter aortic valve implantation (TAVI) is an established treatment option for patients with severe symptomatic aortic stenosis and at increased risk for surgical aortic valve replacement (SAVR). Many novel devices are currently being developed and established transcatheter heart valves undergo design reiterations to address limitations and reduce complication rates associated with the device and implantation procedure. However, device comparisons by use of randomized trials are scarce in particular for newer generation transcatheter valves. The aim of this study is to assess non-inferiority of the self-expandable Symetis ACURATE neo/TF in comparison to the balloon-expandable Edwards SAPIEN 3 transcatheter aortic valve bioprosthesis with regard to early safety and clinical efficacy at 30 days.


Clinical Trial Description

Background: Transcatheter aortic valve implantation (TAVI) is an established and valuable treatment option for patients with severe symptomatic aortic stenosis and at increased risk for surgical aortic valve replacement (SAVR). The use of TAVI is rapidly expanding worldwide and the indications for TAVI are widening into lower risk populations in view of favorable outcomes among high and intermediate risk patients. Many novel devices are currently developed or established devices undergo design reiterations to address limitations, such as vascular access complications, paravalvular regurgitation, and atrio-ventricular conductance disturbances. However, device comparisons by use of randomized trials are scarce in particular for newer generation transcatheter valves. The Symetis ACURATE neo/TF, a self-expandable transcatheter valve delivered via transfemoral access, gained Conformité Européenne (CE) marking in September 2014 after showing favorable procedural and short term results. The SCOPE I trial will compare its performance to the balloon-expandable Edwards SAPIEN 3, a widely used and well-established transcatheter heart valve of the second generation, in a randomized fashion. Objectives: The primary objective is the comparison of the Symetis ACURATE neo/TF to the Edwards SAPIEN 3 transcatheter aortic bioprosthesis with regard to early safety and clinical efficacy at 30 days. Secondary objectives involve the comparison between the two devices with regard to secondary clinical and echocardiographic endpoints at 30 days, 1 year and 3 years. Methods: Sample Size: Based on an anticipated incidence proportion of 22% for the primary non-hierarchical composite endpoint at 30 days in both treatment arms, a non-inferiority margin of 7.7%, a power of 80%, a one-tailed significance level of α = 0.05, and a low attrition rate, the total required sample size amounts to 730 patients. Design: Patients will be allocated to the Symetis ACURATE neo/TF or the Edwards SAPIEN 3 bioprosthesis at a 1:1 ratio by means of a randomly permuted block randomisation stratified on study center and Society of Thoracic Surgeons' predicted risk of mortality score (STS-PROM) strata (< 3%, ≥ 3 to < 8%, ≥ 8%). Analysis: Estimates of the risk-differences between the two treatment arms with regard to the primary endpoint will be pooled over the predefined STS-PROM strata by means of the Cochran-Mantel-Haenszel method and Wald-type confidence limits will be calculated using the Sato variance estimator. The non-inferiority assumption will be tested at a one-sided significance level with a type I error rate (α) = 0.05. The analysis of the primary composite endpoint will be conducted according to the intention-to-treat (ITT) and the per protocol (PP) principle and non-inferiority should be claimed only if met by both. In case non-inferiority is established, a superiority analysis will be performed using a two-tailed significance level with a type I error rate of α = 0.05. Further secondary analyses will evaluate between group differences in relation to demographic, clinical, procedural, functional and imaging characteristics. Pre-specified subgroup analyses will be conducted by use of appropriate interaction tests contrasting categories of sex, STS-PROM score (< 3%, ≥ 3 to < 8%, ≥ 8%), left ventricular ejection fraction (< 50% vs. ≥ 50%), and native aortic valve eccentricity index (≤ 0.25 vs. > 0.25). ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03011346
Study type Interventional
Source University Hospital Inselspital, Berne
Contact
Status Completed
Phase N/A
Start date February 8, 2017
Completion date February 16, 2022

See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease