Aortic Valve Stenosis Clinical Trial
— RADIANTOfficial title:
Transfemoral Replacement of Aortic Valve With HLT MeriDIAN Valve Early Feasibility Trial
| Verified date | May 2023 |
| Source | HLT Inc. |
| Contact | n/a |
| Is FDA regulated | No |
| Health authority | |
| Study type | Interventional |
The purpose of this study is to evaluate the safety and performance of the HLT System in patients with severe aortic stenosis who present at High Risk for aortic valve replacement surgery.
| Status | Terminated |
| Enrollment | 11 |
| Est. completion date | January 20, 2023 |
| Est. primary completion date | January 20, 2023 |
| Accepts healthy volunteers | No |
| Gender | All |
| Age group | 70 Years and older |
| Eligibility | Inclusion Criteria: 1. 70 years of age or older 2. Echocardiographic or hemodynamic based evidence of calcific (senile) aortic stenosis with one of the following: aortic valve EOA <1.0 cm2 or 0.6 cm2/m2, mean aortic valve gradient >40 mmHg or peak aortic valve velocity >4 m/sec 3. Symptoms due to aortic stenosis resulting in one of the following: 1. New York Heart Association (NYHA) Functional Classification of II or greater 2. Presence of angina 3. Presence of syncope 4. Documented aortic valve annular diameter = 21 and = 24 mm (associated perimeter range is 66.0 - 75.4 mm or associated area range of 346 - 452 mm2) measured by the multislice computed tomography (MSCT) Core Lab assessment of pre-procedure imaging. 5. Documented heart team agreement of high risk for surgical aortic valve replacement (SAVR) due to frailty or comorbidities such as: - Society of Thoracic Surgeons (STS) score of =8% - Frailty as indicated by one of the following: - Five meter walk test > 6 seconds - Katz activities of daily living (ADL) score of 3/6 or less - Body Mass Index < 20 kg/m2 - Wheelchair bound, unable to live independently - Childs Class A or B liver disease - Severe lung disease (need for supplemental oxygen, forced expiratory volume at one second (FEV1) < 50% of predicted, diffusing capacity of the lungs for carbon monoxide (DLCO) < 60%, or other evidence of severe pulmonary dysfunction - Previous coronary artery bypass graft(s) at risk for re-operation - Serum albumin < 3.5 g/dL - Other evidence that subject is at high risk for surgical valve replacement by one of the following: - Hostile chest - Porcelain aorta - Severe pulmonary hypertension (> 60 mmHg) - Prior chest radiation therapy - Neuromuscular disease that creates risk for mechanical ventilation or rehabilitation after surgical aortic valve replacement - Orthopedic disease that creates risk for rehabilitation after surgical aortic valve replacement 6. Geographically available, willing to comply with follow up and able to provide written informed consent Exclusion Criteria: 1. Congenital unicuspid or bicuspid aortic valve, or noncalcified aortic valve; or valve eccentricity (calcific or otherwise) which could compromise procedural success. 2. Patients with a coronary height of < 10mm, or otherwise determined to be high risk for coronary obstruction 3. Patients with low flow/low gradient aortic stenosis 4. Patients with significant annular or left ventricular outflow tract (LVOT) calcification that could compromise procedural success 5. Pre-existing prosthetic heart valve in any position 6. Severe aortic, mitral or tricuspid valve regurgitation 7. Moderate to severe mitral stenosis 8. Myocardial infarction within the past 30 days* 9. Echocardiographic evidence of intracardiac mass, thrombus, or vegetation 10. Left Ventricular Ejection Fraction (LVEF) < 30% 11. Severe pulmonary hypertension with pulmonary systolic pressure greater than two- thirds of systemic pressure 12. Hemodynamic instability requiring inotropic drug therapy within the past 14 days 13. Untreated clinically significant coronary artery disease requiring revascularization 14. Presence of significant aortic disease such as atheroma, thrombus, or aneurysm which precludes safe implant delivery 15. Blood dyscrasias defined as leukopenia (White blood cell count < 1,000 cell/mm3), anemia (hemoglobin < 9.0 g/dL), thrombocytopenia (platelet count < 50,000 cells/mm3), history of bleeding diathesis or coagulopathy 16. Patient ineligible for or refuses blood transfusions 17. Unfavorable peripheral vascular anatomy or disease (e.g. severe obstructive calcification, severe tortuosity) that would preclude passage of 18 French (18F) catheters from the femoral arterial access to the aorta as evidenced by peripheral MSCT 18. Active peptic ulcer or gastrointestinal bleeding within the past 90 days, that would not allow treatment with the protocol antiplatelet regimen post implant * 19. Symptoms of carotid or vertebral artery disease (e.g. stroke or transient ischemic attack) within past 6 months, or treatment of carotid stenosis within past two months* 20. Renal disease as demonstrated by a serum creatinine > 2.5 mg/dL or end stage renal disease 21. Active infection (including endocarditis) requiring ongoing treatment 22. Need for emergent surgery or intervention other than the investigational procedure 23. Any therapeutic invasive cardiac procedure performed or planned to perform within 30 days of the index procedure, except for percutaneous coronary intervention (PCI) which is performed within 7 days prior to the index procedure* 24. Hypersensitivity or contraindication to procedural medication and device materials (e.g. titanium, nickel, pork) which cannot be adequately premedicated 25. Life expectancy < 1 year due to non-cardiac co-morbid conditions 26. Currently participating in any investigational drug or device studies that may confound the results of this study 27. History of any cognitive or mental health status that would interfere with study participation 28. Following surgical consultation, patient is deemed inoperable in the event that surgical intervention is required after Meridian valve implantation 29. Patients with a history of hypertrophic cardiomyopathy 30. Aortic root angle = 70° as determined by the MSCT Core Lab assessment of pre- procedure imaging 31. Unfavorable left ventricular anatomy (e.g., size or shape) as evidenced by pre- procedure imaging * At the time of procedure, if a subject's medical status has changed since enrollment, the subject shall be re-evaluated for eligibility |
| Country | Name | City | State |
|---|---|---|---|
| United States | The Lindner Center for Research and Education at the Christ Hospital | Cincinnati | Ohio |
| United States | St. Vincent Heart Center of Indiana | Indianapolis | Indiana |
| United States | NYU Langone Medical Center | New York | New York |
| United States | Baylor Scott & White The Heart Hospital Plano | Plano | Texas |
| United States | MedStar Health | Washington | District of Columbia |
| Lead Sponsor | Collaborator |
|---|---|
| HLT Inc. |
United States,
| Type | Measure | Description | Time frame | Safety issue |
|---|---|---|---|---|
| Primary | Primary Endpoint: Mortality at 30 days | The primary safety endpoint is all-cause mortality at 30 days. | 30 days | |
| Secondary | Secondary Performance Endpoint 1: Procedural Device Performance | The secondary performance endpoint is Device Success defined as:
Absence of procedural mortality AND Correct positioning of a single Valve into the proper anatomical location AND Intended performance of the Valve (no severe prosthesis-patient mismatch and clinically acceptable gradient) AND no moderate or severe aortic valve regurgitation) |
1 day | |
| Secondary | Secondary Performance Endpoint 2: Post-procedural Valve Performance | The Valve performance will be evaluated by the following parameters with echocardiograms obtained at pre-discharge, 1, 6, 12, 24, 36, 48 and 60 months:
Aortic valve effective orifice area (EOA) Severity of aortic valve regurgitation (AR) Aortic valve gradient |
pre-discharge, 1, 6, 12, 24, 36, 48 and 60 months | |
| Secondary | Secondary Safety Endpoint 3: Adverse Events | All adverse events will be assessed throughout the 5 year follow up period. | Throughout the 5 year follow up period |
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Completed |
NCT03186339 -
Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
|
||
| Recruiting |
NCT03549559 -
Imaging Histone Deacetylase in the Heart
|
N/A | |
| Terminated |
NCT02854319 -
REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System
|
N/A | |
| Recruiting |
NCT05601453 -
The ReTAVI Prospective Observational Registry
|
||
| Withdrawn |
NCT05481814 -
CPX in Paradoxical Low Flow Aortic Stenosis
|
||
| Completed |
NCT02241109 -
Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity
|
N/A | |
| Completed |
NCT01700439 -
Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve
|
N/A | |
| Recruiting |
NCT04429035 -
SLOW-Slower Progress of caLcificatiOn With Vitamin K2
|
N/A | |
| Completed |
NCT04103931 -
Impact of a Patient Decision Aid for Treatment of Aortic Stenosis
|
N/A | |
| Completed |
NCT03950440 -
Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
|
||
| Active, not recruiting |
NCT02661451 -
Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD)
|
N/A | |
| Completed |
NCT02792452 -
Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
|
||
| Completed |
NCT02758964 -
Evaluation of Cerebral Thrombembolism After TAVR
|
||
| Completed |
NCT02847546 -
Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation
|
N/A | |
| Not yet recruiting |
NCT02536703 -
Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population
|
Phase 3 | |
| Not yet recruiting |
NCT02541877 -
Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve
|
Phase 3 | |
| Not yet recruiting |
NCT02221921 -
Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI
|
N/A | |
| Completed |
NCT02249000 -
BIOVALVE - I / II Clincial Investigation
|
N/A | |
| Active, not recruiting |
NCT02080299 -
Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation
|
Phase 2 | |
| Terminated |
NCT01939678 -
Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease
|