Clinical Trials Logo

Clinical Trial Summary

Transcatheter aortic valve implantation (TAVI) has emerged as a valuable minimal-invasive treatment option in patients with symptomatic severe aortic valve (AV) stenosis at prohibitive or increased risk for conventional open-heart surgery. Recent randomized clinical trials reported a large treatment effect of TAVI over medical treatment among inoperable patients and similar or superior outcomes compared with surgical aortic valve replacement in high to intermediate risk patients. However, atrio-ventricular conduction disturbances and arrhythmias (in particular atrial fibrillation) before, during or after TAVI remain a matter of concern as they have important consequences. The objective of this study is to investigate the incidence, nature and prognostic significance of AV-conduction disturbances and arrhythmias among patients with severe, symptomatic aortic stenosis undergoing TAVI before, during and after the procedure using a small implantable cardiac monitoring system (ICM; Medtronic REVEAL LinQTM). One hundred patients will be enrolled in this study. Prior to TAVI (at least 4 weeks), at the time of preprocedural hemodynamic and anatomical assessment, the ICM will be inserted under the skin of the chest under local anesthesia. The device will be interrogated just prior to readmission for TAVI and thereafter at 1, 3, 6, and 12 months of follow-up. The incidence of symptomatic as well as silent brady- and tachyarrhythmias will be recorded, and its impact on medical and device treatment as well as clinical outcomes analyzed. The present study will provide information about the actual incidence and impact of symptomatic and silent arrhythmias and AV-conduction disturbances among patients with severe, symptomatic aortic stenosis undergoing TAVI. Specifically, the study estimate the burden of arrhythmias before TAVI and to accurately determine the incidence of new onset atrial fibrillation and complete AV-block within 12 months after the procedure. Identifying patients at risk for AV- conduction abnormalities, atrial fibrillation (AF), and non-sustained or sustained ventricular arrhythmias may guide future preventive measures, medical treatment and improve patients outcomes after TAVI.


Clinical Trial Description

Background TAVI has emerged as a valuable minimal-invasive treatment option in patients with symptomatic severe aortic valve stenosis at prohibitive or increased risk for conventional open-heart surgery. AV conduction disturbances and arrhythmias before, during or after TAVI remain a matter of concern as they have consequences. Prior to TAVI the ICM will be inserted under the skin of the chest under local anesthesia. The device will be interrogated just prior to readmission for TAVI and thereafter at 1, 3, 6, and 12 months of follow-up. The incidence of symptomatic as well as silent brady- and tachyarrhythmias will be recorded, and its impact on medical and device treatment as well as clinical outcomes analyzed. All patients with severe, symptomatic aortic stenosis undergoing TAVI at the institution irrespective selected bioprosthesis will be included in the study. Final decision on eligibility will be made by the local Heart Team. Objective To investigate the incidence, nature and prognostic significance of AV-conduction disturbances and arrhythmias among patients with severe, symptomatic aortic stenosis undergoing TAVI before, during and after the procedure using a small implantable cardiac monitoring system (ICM; Medtronic REVEAL LinQTM). The primary endpoint of the study is to establish the incidence of new onset atrial fibrillation and complete AV-block within 12 months after TAVI. Methods One hundred patients with severe, symptomatic aortic stenosis undergoing TAVI will be enrolled in this prospective, observational study. Prior to TAVI (at least 4 weeks), at the time of preprocedural hemodynamic and anatomical assessment, the ICM will be inserted under the skin of the chest under local anesthesia. The device will be interrogated just prior to readmission for TAVI and thereafter at 1, 3, 6, and 12 months of follow-up. The incidence of symptomatic as well as silent brady- and tachyarrhythmias will be recorded, and its impact on medical and device treatment as well as clinical outcomes analyzed. The study is observational: the patients will not be assigned to a specific intervention. Patients consenting will be monitored using a specific device that has been approved for market release. The objective of the study is to use the information obtained with this monitoring device to assess the incidence, nature and prognostic significance of atrioventricular conduction disturbances and arrhythmias among patients with severe, symptomatic aortic stenosis undergoing Transcatheter Aortic Valve Implantation before, during and after the procedure. The objective of the study is not to investigate the performance of the monitoring device. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02559011
Study type Observational
Source University Hospital Inselspital, Berne
Contact
Status Completed
Phase
Start date March 2016
Completion date November 16, 2020

See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease