Aortic Valve Stenosis Clinical Trial
Official title:
The Engager ALIGN Study. To Characterize the Safety and Clinical Benefit of the Engager Transcatheter Aortic Valve Implantation System in a Real World Environment.
Purpose To characterize the safety and clinical benefit of the Engager Transcatheter Aortic
Valve Implantation System in a real world environment.
Design Prospective non-randomized, non-interventional, multicenter, single-arm, post-market
study.
250 Patients will have the Engager bioprosthesis implanted. Patients will be followed at 1
month, 6 months, and 12 months after the procedure. The recruitment period will be
approximately 12 months, so the total study duration will be 24 months.
The study objective is to characterize the safety and clinical benefit of the Engager
Transcatheter Aortic Valve Implantation System in a real world setting.
The primary endpoint of this study is all-cause mortality at 30 days or during index
hospitalization.
Secondary endpoints of this study are:
- Device success according to VARC2 is defined as:
- absence of procedural mortality (all-cause mortality at discharge, 30 days or during
index hospitalization), AND
- correct positioning of the Engager bioprosthesis in the proper anatomic location, AND
- Engager bioprosthesis performing as intended (no prosthesis-patient mismatch and mean
aortic valve gradient < 20 mmHg or peak velocity < 3 m/s, AND no moderate or severe
regurgitation).
- Composite early safety (at 30 days) according to VARC2 includes the following
components:
- all-cause mortality
- all stroke
- life-threatening bleeding
- acute kidney injury (stage 2-3)
- coronary artery obstruction requiring intervention
- major vascular complication
- valve-related dysfunction requiring repeat procedure (BAV, TAVI or SAVR)
- Clinical efficacy according to VARC2 at 6 months and 1 year is defined as:
- all-cause mortality
- all stroke
- hospitalizations for valve-related symptoms or worsening congestive heart failure (CHF)
- NYHA class III or IV
- valve-related dysfunction (mean aortic valve gradient ≥20 mm Hg, effective orifice area
(EOA) ≤0.9-1.1 cm² and/or Doppler velocity index (DVI) <0.35 m/s, AND/OR moderate or
severe prosthetic valve regurgitation)
- Time-related valve safety accordingly to VARC2 at 6 months and 1 year is defined as:
- Structural valve deterioration
- Valve-related dysfunction (mean aortic valve gradient ≥20 mm Hg, (EOA) ≤0.9-1.1 cm²
and/or (DVI) <0.35 m/s, AND/OR moderate or severe prosthetic valve regurgitation)
- Requiring repeat procedure (TAVI or SAVR)
- Prosthetic valve endocarditis
- Prosthetic valve thrombosis
- Thrombo-embolic events (e.g. stroke)
- VARC bleeding, unless clearly unrelated to valve therapy (e.g. trauma)
- All-cause mortality at 6 months and 1 year
- Cardiovascular mortality at 30 days, 6 months and 1 year
- Incidence of TAVI-related complications at 30 days, 6 months and 1 year:
- Myocardial infarction
- Periprocedural and spontaneous stroke
- Life-threatening, major and minor bleedings
- Acute kidney injury state 1, 2 and 3
- Apical and vascular complications
- Conduction disturbances
- Conversion to open-heart surgery
- Unplanned use of cardiopulmonary bypass
- Coronary obstruction and dissection
- Ventricular septal perforation
- Mitral valve apparatus damage or dysfunction
- Cardiac tamponade
- Endocarditis
- Valve thrombus
- Valve migration, embolization or ectopic valve deployment
- Valve in valve deployment
- Total, transvalvular and paravalvular regurgitation as measured by TTE at 30 days
and 1 year
- Mean aortic valve gradient, peak velocity and effective orifice area as measured by
TTE at 30 days and 1 year
- Engager implant depth as measured by standard of care angiography at the end of
implant procedure
- Incidence and rationale for permanent pacemaker implantation after Engager implant
procedure
- Changes in Quality of Life as measured by the EQ5D questionnaire at baseline,
discharge, 30 days, 6 months and 1 year
- Length of stay during index hospitalization (ICU and general ward)
- Incidence of re-hospitalization at 30 days, 6 months and 1 year
Subject population All patients with severe aortic stenosis requiring treatment, who are
selected by a heart team to be treated electively with the Engager Transcatheter Aortic Valve
Implantation System are eligible to be included in this study.
Treatment The Engager Transcatheter Aortic Bioprosthesis will be implanted using the Engager
Transcatheter Delivery System. The bioprosthesis is delivered transapically on a catheter
during a beating heart procedure.
;
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Completed |
NCT03186339 -
Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
|
||
| Recruiting |
NCT03549559 -
Imaging Histone Deacetylase in the Heart
|
N/A | |
| Terminated |
NCT02854319 -
REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System
|
N/A | |
| Recruiting |
NCT05601453 -
The ReTAVI Prospective Observational Registry
|
||
| Withdrawn |
NCT05481814 -
CPX in Paradoxical Low Flow Aortic Stenosis
|
||
| Completed |
NCT02241109 -
Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity
|
N/A | |
| Completed |
NCT01700439 -
Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve
|
N/A | |
| Recruiting |
NCT04429035 -
SLOW-Slower Progress of caLcificatiOn With Vitamin K2
|
N/A | |
| Completed |
NCT04103931 -
Impact of a Patient Decision Aid for Treatment of Aortic Stenosis
|
N/A | |
| Completed |
NCT03950440 -
Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
|
||
| Active, not recruiting |
NCT02661451 -
Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD)
|
N/A | |
| Completed |
NCT02758964 -
Evaluation of Cerebral Thrombembolism After TAVR
|
||
| Completed |
NCT02792452 -
Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
|
||
| Completed |
NCT02847546 -
Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation
|
N/A | |
| Not yet recruiting |
NCT02541877 -
Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve
|
Phase 3 | |
| Not yet recruiting |
NCT02536703 -
Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population
|
Phase 3 | |
| Completed |
NCT02249000 -
BIOVALVE - I / II Clincial Investigation
|
N/A | |
| Not yet recruiting |
NCT02221921 -
Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI
|
N/A | |
| Active, not recruiting |
NCT02080299 -
Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation
|
Phase 2 | |
| Terminated |
NCT01939678 -
Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease
|