Clinical Trials Logo

Clinical Trial Summary

The purpose of the RESPOND post market study is to collect real world clinical and device performance outcomes data with the Lotus Valve System used in routine clinical practice to demonstrate that the commercially available Lotus Valve System is a safe and effective treatment for patients with severe calcific aortic stenosis.


Clinical Trial Description

The RESPOND study is a prospective, open label, single arm, multi-center, observational post market study designed to collect real world clinical and device performance outcomes data of the commercially available Lotus Valve used in routine clinical practice for the treatment of severe calcific aortic stenosis. Approximately 1000 real-world, consecutive subjects will be enrolled at up to 50 study centers in Europe, Asia Pacific and Central/South America. All enrolled subjects will be contacted for follow-up at 30 days, 1, 2, 3, 4 and 5 years post index valve implantation. Follow-up visit at 1 year post valve implantation should be conducted via outpatient clinic visit. Follow-up visits at 30 days and 2 through 5 years may be conducted in person (preferred) and via telephone interview. Subjects who are not implanted with a Lotus Valve will be followed for safety through 30 days after the initial attempted index procedure. Collection of safety events will include any serious adverse event (SAE) that led to death, serious adverse device effect (SADE), adverse device effect (ADE), unanticipated serious adverse device effect (USADE), and all Valve Academic Research Consortium (VARC) events regardless of seriousness and device relationship through 5 year follow-up. The RESPOND study will be conducted in accordance with the International Organization for Standardization (ISO) 14155: 2011; ethical principles that have their origins in the Declaration of Helsinki; the relevant parts of the International Conference on Harmonization (ICH) Guidelines for Good Clinical Practices (GCP); and pertinent individual country/state/local laws and regulations. An additional cohort of approximately 50 subjects will be enrolled at up to 6 study centers in Europe after enrollment in the main cohort is completed to assess center-driven implantation technique with the commercially available Lotus Valve with Depth Guard technology. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02031302
Study type Observational
Source Boston Scientific Corporation
Contact
Status Completed
Phase
Start date May 27, 2014
Completion date May 18, 2021

See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease