Aortic Valve Stenosis Clinical Trial
Official title:
Clinical Evaluation of Percutaneous Implantation of the CoreValve Aortic Valve Prosthesis. Safety and Performance Study on Patients at High Risk for Surgical Valve Replacement (18Fr Safety and Efficacy Study)
| NCT number | NCT01051518 |
| Other study ID # | COR-2006-02 |
| Secondary ID | |
| Status | Completed |
| Phase | N/A |
| First received | |
| Last updated | |
| Start date | May 2006 |
| Est. completion date | June 2013 |
| Verified date | February 2019 |
| Source | Medtronic Cardiovascular |
| Contact | n/a |
| Is FDA regulated | No |
| Health authority | |
| Study type | Interventional |
The investigation concerns a prospective, multicenter, single arm safety and performance
study evaluating the Medtronic CoreValve system. Approximately 120 patients presenting with
symptomatic aortic native valve stenosis necessitating valve replacement which are considered
poor surgical candidates, with a high surgical risk, as attested to by both the surgeon and
the cardiologist are recruited in the study.
Safety and performance will be evaluated at discharge and at 30 days post-procedure. Valve
performance and placement will be followed up at 3 and 6 months post-procedure. Further
long-term patient follow-up visits will be performed at 12, 24, 36 and 48 months
post-procedure.
| Status | Completed |
| Enrollment | 126 |
| Est. completion date | June 2013 |
| Est. primary completion date | February 2009 |
| Accepts healthy volunteers | No |
| Gender | All |
| Age group | 75 Years and older |
| Eligibility |
Inclusion Criteria: - Native aortic valve disease, defined as valve stenosis with an aortic valve area <1cm² (<0.6cm2/m2) as determined by echocardiographic measure, - = 75 years, or - Surgical risk calculated with logistic EuroSCORE = 15 %, or - One or two (but not more than 2) of the following complicating factors: 1. Cirrhosis of the liver (Child class A or B), 2. Pulmonary insufficiency : Forced expiratory volume in one second (FEV1) < 1 liter, 3. Previous cardiac surgery (Coronary artery bypass grafting (CABG), valvular surgery), 4. Pulmonary hypertension > 60 mmHg and high risk of cardiac surgery other than valve replacement, 5. Porcelain aorta 6. Recurrent pulmonary embolus, 7. Right ventricular insufficiency, 8. Thoracic burning sequelae contraindicating open chest surgery, 9. History of mediastinum radiotherapy, 10. Severe connective tissue disease resulting in a contraindication to surgery, 11. Cachexia (BMI = 18 kg/m²), - Aortic valve annulus diameter is = 20 mm and = 27 mm as determined by echocardiographic measure, - Ascending aorta diameter £ 45 mm at the sino-tubular junction, and - Signed Informed Consent. Exclusion Criteria: - Known hypersensitivity or contraindication to aspirin, heparin, ticlopidine, clopidogrel, Nitinol, or sensitivity to contrast media which cannot be adequately pre-medicated, - Any sepsis, including active endocarditis, - Recent myocardial infarction (< 30 days), - Percutaneous coronary or vascular intervention within 15 days prior to the study procedure, or scheduled during or within 30 days after the study procedure, - Any left ventricular or atrial thrombus diagnosed by echocardiography, - Uncontrolled atrial fibrillation (heart rate greater than 100 bpm), - Mitral or tricuspid valvular insufficiency ( > grade II), - Previous aortic valve replacement (mechanical valve OR stented bioprosthetic valve), - Any condition considered as contraindication for extracorporeal assistance, - Evolutive or recent CVA (cerebro vascular accident), - Poly arterial patients with either: 1. Femoral, iliac or aortic vascular condition (e.g. stenosis, tortuosity), that make insertion and endovascular access to the aortic valve impossible, or 2. Symptomatic carotid or vertebral arteries narrowing (> 70%) disease, or 3. Abdominal or thoracic aortic aneurysm, - Bleeding diathesis or coagulopathy, or patient who will refuse blood transfusion, - Evolutive disease with life expectancy less than one year, - Creatinine clearance < 20 ml/min, - Pregnancy, and - Enrolled in another investigational study. |
| Country | Name | City | State |
|---|---|---|---|
| Canada | University of Alberta Hospital | Edmonton | |
| Canada | Institut de Cardiologie de Montreal | Montreal | |
| Canada | University of Ottawa Heart Institute | Ottawa | |
| Germany | Herzzentrum Leipzig GmbH | Leipzig | |
| Germany | HELIOS Heart Center Siegburg | Siegburg | |
| Netherlands | Amphia Hospital | Breda | |
| Netherlands | Erasmus MC | Rotterdam | |
| United Kingdom | Glenfield Hospital | Leicester | |
| United Kingdom | Royal Brompton & Harefield NHS Trust | London |
| Lead Sponsor | Collaborator |
|---|---|
| Medtronic Bakken Research Center |
Canada, Germany, Netherlands, United Kingdom,
| Type | Measure | Description | Time frame | Safety issue |
|---|---|---|---|---|
| Primary | Composite Major Adverse Event (MAE) Free Rate | Percentage of subjects without a composite major adverse event (MAE) at 30 (+ 7) days post-procedure. MAE included all-cause death, non-fatal myocardial infarction, stroke, emergent cardiac re-intervention, cardiac tamponade, non-structural or structural valve dysfunction, cardiogenic shock, endocarditis, TIA, embolism, aortic dissection, access site vessel dissection, vessel perforation, acute vessel occlusion, major bleeding and major vascular injury. | 30 (+7) days post procedure | |
| Secondary | Composite Technical Device Success | Composite technical success was defined as the percentage of subjects in whom success on all four technical measures of the "Device Functionality Assessment" was achieved and who were adjudicated as having no device failure or malfunction. The four measures of the ''Device Functionality Assessment'' were: Load the valve delivery system using the loading system Access the aortic valve with the delivery catheter Deploy the valve accurately across the native aortic valve Remove the intact delivery system |
Was assessed during the procedure and completed once the procedure was conlcluded |
| Status | Clinical Trial | Phase | |
|---|---|---|---|
| Completed |
NCT03186339 -
Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
|
||
| Recruiting |
NCT03549559 -
Imaging Histone Deacetylase in the Heart
|
N/A | |
| Terminated |
NCT02854319 -
REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System
|
N/A | |
| Recruiting |
NCT05601453 -
The ReTAVI Prospective Observational Registry
|
||
| Withdrawn |
NCT05481814 -
CPX in Paradoxical Low Flow Aortic Stenosis
|
||
| Completed |
NCT02241109 -
Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity
|
N/A | |
| Completed |
NCT01700439 -
Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve
|
N/A | |
| Recruiting |
NCT04429035 -
SLOW-Slower Progress of caLcificatiOn With Vitamin K2
|
N/A | |
| Completed |
NCT04103931 -
Impact of a Patient Decision Aid for Treatment of Aortic Stenosis
|
N/A | |
| Completed |
NCT03950440 -
Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
|
||
| Active, not recruiting |
NCT02661451 -
Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD)
|
N/A | |
| Completed |
NCT02792452 -
Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
|
||
| Completed |
NCT02758964 -
Evaluation of Cerebral Thrombembolism After TAVR
|
||
| Completed |
NCT02847546 -
Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation
|
N/A | |
| Not yet recruiting |
NCT02536703 -
Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population
|
Phase 3 | |
| Not yet recruiting |
NCT02541877 -
Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve
|
Phase 3 | |
| Not yet recruiting |
NCT02221921 -
Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI
|
N/A | |
| Completed |
NCT02249000 -
BIOVALVE - I / II Clincial Investigation
|
N/A | |
| Active, not recruiting |
NCT02080299 -
Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation
|
Phase 2 | |
| Terminated |
NCT01939678 -
Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease
|