Clinical Trials Logo

Clinical Trial Summary

The proposed investigation is a prospective, multicenter, non-randomized study to evaluate the immediate benefits (at discharge and at 30 days) in terms of performance and safety of the implantation of the Medtronic CoreValve PAV in a failing aortic bioprosthesis. In addition, the study aims to evaluate the performance and the safety of the implantation of the Medtronic CoreValve PAV in a failing aortic bioprosthesis at subsequent annual follow-ups out to 48 months post procedure.

These objectives will be achieved through the following endpoints:

- Primary safety endpoint - Composite of Major Adverse Events

- Primary performance endpoint - Technical and procedural success at discharge

Patient Population: Eligible subjects will be at least 75 years old, presenting with a failing aortic bioprosthesis (stenotic, incompetent or mixed) including homograft or stented or stentless heterograft, considered poor surgical candidates and necessitating repeat aortic valve replacement. Up to 20 patients will be included in up to four hospitals.


Clinical Trial Description

n/a


Study Design


Related Conditions & MeSH terms


NCT number NCT01051310
Study type Interventional
Source Medtronic Cardiovascular
Contact
Status Completed
Phase N/A
Start date June 2008
Completion date January 2011

See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease