Clinical Trials Logo

Clinical Trial Summary

The purpose of this trial is to generate clinical evidence on valve safety and performance of self-expanding (SE) versus balloon-expandable (BE) transcatheter aortic valve replacement (TAVR) in subjects with a small aortic annulus and symptomatic severe native aortic stenosis. Additionally, a stress echocardiography sub-study will be conducted as part of the SMART Trial at select sites. The purpose of the sub-study is to evaluate performance of SE versus BE TAVR in subjects with a small aortic annulus and symptomatic severe native aortic stenosis after undergoing exercise stress echocardiographic testing.


Clinical Trial Description

This is a prospective, multi-center, international, randomized controlled, post-market trial. The primary objectives of the trial are to demonstrate clinical non-inferiority and hemodynamic superiority of the Evolut PRO/PRO+/FX System when compared to subjects treated with the SAPIEN 3/3 Ultra System at 12 months post-procedure. Subjects will be randomized on a 1:1 basis to receive TAVR with either a Medtronic SE Transcatheter Aortic Valve (TAV) or an Edwards BE Transcatheter Heart Valve (THV). Data will be collected at pre- and post-procedure, at discharge, at 30 days, and once a year until the 5-year follow-up is completed. Product Names: - Medtronic Evolut PRO and Evolut PRO+ TAV Systems, Evolut FX System (Commercially available in the United States and may be used upon commercial availability in Canada.) - Edwards SAPIEN 3 and SAPIEN 3 Ultra THV Systems The exercise stress echocardiographic testing at select SMART Trial sites seeks to evaluate the performance of the prosthetic aortic valve during exercise. The stress echocardiogram assessment will be conducted as part of the 12-month visit for participating subjects. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04722250
Study type Interventional
Source Medtronic Cardiovascular
Contact
Status Active, not recruiting
Phase N/A
Start date April 2, 2021
Completion date December 2027

See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Active, not recruiting NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease