Aortic Valve Stenosis Clinical Trial
Official title:
Hemodynamic Matched Comparison of the Balloon-Expandable Transcatheter Heart Valves Myval and Sapien-3 for the Treatment of Aortic Stenosis
Transcatheter aortic valve implantation (TAVI) is recommended for patients with severe aortic stenosis (AS) at high to intermediate surgical risk. Despite similar mortality rates compared to surgical aortic valve replacement (SAVR) in this setting, the rate para-valvular leak (PVL) remains higher and has been associated to higher mortality even at mild degree. This is one of the major concerns to extend TAVI to low surgical risk, although the favorable results from PARTNER 3. The presence of moderate to severe PVL after TAVI is associated to a 2- and 3- fold increase in the mortality rate at 30-day and 1-year follow-up, respectively (24-29). Prosthesis-patient mismatch (PPM) adversely affects functional improvement and exercise tolerance, left ventricular (LV) mass regression, and late structural valve deterioration. Many studies have previously investigated PPM after surgical AVR suggesting the presence of this problem in more than 40% of the surgically treated patients. This rate was significantly lower with the balloon-expandable Sapien (Edwards Lifesciences, Irvine, California), with PPM that varied from 8% to 18%, but in both cases (patients harboring TAVI and those with SAVR) the mortality rate was higher in the presence of PPM. Under the hypothesis that there are differences in terms of transvalvular gradients and residual para-valvular leak amongst different balloon-expandable TAVI devices available in the market, the aim of the MATCH-BALL study is to compare the hemodynamic performance of two balloon-expandable TAVI devices, Sapien 3 (Edwards Lifesciences, Irvine, CA, USA) and Myval (Meril Life Sciences Pvt. Ltd., India).
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03186339 -
Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
|
||
Recruiting |
NCT03549559 -
Imaging Histone Deacetylase in the Heart
|
N/A | |
Terminated |
NCT02854319 -
REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System
|
N/A | |
Recruiting |
NCT05601453 -
The ReTAVI Prospective Observational Registry
|
||
Withdrawn |
NCT05481814 -
CPX in Paradoxical Low Flow Aortic Stenosis
|
||
Completed |
NCT02241109 -
Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity
|
N/A | |
Completed |
NCT01700439 -
Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve
|
N/A | |
Recruiting |
NCT04429035 -
SLOW-Slower Progress of caLcificatiOn With Vitamin K2
|
N/A | |
Completed |
NCT04103931 -
Impact of a Patient Decision Aid for Treatment of Aortic Stenosis
|
N/A | |
Completed |
NCT03950440 -
Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
|
||
Active, not recruiting |
NCT02661451 -
Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD)
|
N/A | |
Completed |
NCT02792452 -
Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
|
||
Completed |
NCT02847546 -
Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation
|
N/A | |
Completed |
NCT02758964 -
Evaluation of Cerebral Thrombembolism After TAVR
|
||
Not yet recruiting |
NCT02541877 -
Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve
|
Phase 3 | |
Not yet recruiting |
NCT02536703 -
Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population
|
Phase 3 | |
Completed |
NCT02249000 -
BIOVALVE - I / II Clincial Investigation
|
N/A | |
Not yet recruiting |
NCT02221921 -
Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI
|
N/A | |
Active, not recruiting |
NCT02080299 -
Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation
|
Phase 2 | |
Terminated |
NCT01939678 -
Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease
|