Aortic Valve Stenosis Clinical Trial
Official title:
A Prospective, Randomized, Multicenter Evaluation of the Safety and Effectiveness of the EMBLOK Embolic Protection System During Transcatheter Aortic Valve Replacement
The objective of the study is to evaluate the safety, effectiveness, and performance of the EMBLOK EPS during TAVR by randomized comparison with a commercially available embolic protection device. The targeted study population consists of patients meeting FDA-approved indications for TAVR with commercially available transcatheter heart valve systems. This prospective, multicenter, single-blind, randomized controlled trial will enroll up to a total of 532 subjects undergoing TAVR at up to 30 investigational sites in the United States. All subjects will undergo clinical follow-up (including detailed neurological assessments) in-hospital and at 30 days.
Embolic stroke remains a major complication for TAVR, resulting in a two-fold increase in 1-year mortality. Embolic protection devices have been developed to filter embolic debris during the procedure, potentially reducing the occurrence of neurologic events associated with TAVR. The EMBLOK EPS may improve on currently available devices by capturing and retrieving debris directed toward all 3 cerebral vessels in the aortic arch as well as the descending aorta. The objective of the study is to evaluate the safety, effectiveness, and performance of the EMBLOK EPS during TAVR by randomized comparison with a commercially available embolic protection device. With this comparator device, the left subclavian artery and descending aorta are not protected. The targeted study population consists of patients meeting FDA-approved indications for TAVR with commercially available transcatheter heart valve systems. This prospective, multicenter, single-blind, randomized controlled trial will enroll up to a total of 532 subjects undergoing TAVR at up to 30 investigational sites in the United States. Prior to enrollment of the first randomized subject at each site, each site will enroll 2 Roll-In subjects (up to 60 subjects total), who will not be randomized but will receive the EMBLOK EPS during TAVR. In the randomized cohort, up to 422 subjects meeting eligibility criteria will be randomized 1:1 (stratified by operative risk and study site) to one of two treatment arms: 1. Intervention - EMBLOK EPS during TAVR 2. Control - SENTINEL CPS during TAVR In addition, a nested registry will enroll up to 50 subjects who meet clinical eligibility criteria and are anatomically suitable for the EMBLOK EPS, but whose anatomy precludes the use of the SENTINEL CPS. All subjects will undergo clinical follow-up (including detailed neurological assessments) in-hospital and at 30 days. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03186339 -
Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
|
||
Recruiting |
NCT03549559 -
Imaging Histone Deacetylase in the Heart
|
N/A | |
Terminated |
NCT02854319 -
REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System
|
N/A | |
Recruiting |
NCT05601453 -
The ReTAVI Prospective Observational Registry
|
||
Withdrawn |
NCT05481814 -
CPX in Paradoxical Low Flow Aortic Stenosis
|
||
Completed |
NCT02241109 -
Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity
|
N/A | |
Completed |
NCT01700439 -
Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve
|
N/A | |
Recruiting |
NCT04429035 -
SLOW-Slower Progress of caLcificatiOn With Vitamin K2
|
N/A | |
Completed |
NCT04103931 -
Impact of a Patient Decision Aid for Treatment of Aortic Stenosis
|
N/A | |
Completed |
NCT03950440 -
Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
|
||
Active, not recruiting |
NCT02661451 -
Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD)
|
N/A | |
Completed |
NCT02792452 -
Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
|
||
Completed |
NCT02847546 -
Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation
|
N/A | |
Completed |
NCT02758964 -
Evaluation of Cerebral Thrombembolism After TAVR
|
||
Not yet recruiting |
NCT02541877 -
Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve
|
Phase 3 | |
Not yet recruiting |
NCT02536703 -
Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population
|
Phase 3 | |
Completed |
NCT02249000 -
BIOVALVE - I / II Clincial Investigation
|
N/A | |
Not yet recruiting |
NCT02221921 -
Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI
|
N/A | |
Active, not recruiting |
NCT02080299 -
Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation
|
Phase 2 | |
Terminated |
NCT01939678 -
Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease
|