Aortic Valve Disease Clinical Trial
Official title:
Clinical Data Collection on Perceval S Sutureless Prosthetic Aortic Valve in the Chinese Population
The objective of the study is to evaluate the safety information on the Perceval S sutureless prosthetic heart valve after the implantation for aortic valve disease. The study is designed as a post-market, observational, non-interventional retrospective and prospective registry.
In order to monitor the ongoing safety of the Perceval S as part of regulatory requirements, the study aims to retrospectively collect safety outcomes and performance data in patients with aortic valve disease implanted with Perceval S since 2022. The data will be used for regulatory purposes, to support the re-certification of the valve in the Chinese market. Serious Adverse Events (SAEs) such as valve-related death, structural valve deterioration, cerebral thromboembolism, stroke, Transient Ischemic Attack, non-cerebral thromboembolism, major bleeding, re-operation will be studied to describe the safety profile of the valve. Hemodynamic data from site reported echocardiography finding (mean gradient, peak gradient, effective orifice area, effective orifice area indexed, incidence and degree of PVL and central leak) at hospital discharge will also be evaluated. Data of approximately 80 subjects will be collected in four clinical sites in China. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04149600 -
Identification of Genetic Causes of Calcific Aortic Valve Disease
|
||
Recruiting |
NCT06001489 -
The Effects of 360-degree Virtual Reality on Pre-procedural Anxiety in Patients Awaiting Elective Cardiac Surgery Involving a Sternotomy
|
N/A | |
Not yet recruiting |
NCT04430972 -
Immune Responsiveness and Outcome After Aortic Valve Surgery (Measure)
|
||
Completed |
NCT02467062 -
Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease.
|
N/A | |
Not yet recruiting |
NCT02221921 -
Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI
|
N/A | |
Terminated |
NCT02128841 -
Comparison of Antithrombotic Treatments After Aortic Valve Replacement. Rivaroxaban: A New Antithrombotic Treatment for Patients With Mechanical Prosthetic Aortic Heart Valve.
|
Phase 2 | |
Active, not recruiting |
NCT01194362 -
A Study to Identify Differences in Gene Expression in Patients With Bicuspid and Tricuspid Valve Disease
|
||
Not yet recruiting |
NCT05975567 -
Deploying Novel Imaging Modalities Towards a Three-dimensional (3D) CARDIOvascular PATHology
|
||
Recruiting |
NCT06025149 -
The Study on the Use of "UniLine" Bioprosthesis in the Treatment of Isolated Aortic and Mitral Valve Diseases
|
||
Completed |
NCT05082337 -
The SAVVY Guidewire in Transcatheter Aortic Valve Replacement Procedures
|
N/A | |
Completed |
NCT05193760 -
Robustness Check of Placement and Measurement Algorithms for Blood Flow Measurement on Common Carotid Artery
|
||
Not yet recruiting |
NCT05941455 -
A Prospective Multicenter Pivotal Study to Evaluate Safety and Effectiveness of Venus-Neo Surgical Aortic Valve
|
N/A | |
Active, not recruiting |
NCT04950192 -
Philips Intracardiac Echocardiography (ICE) Clinical Registry
|
||
Active, not recruiting |
NCT03924661 -
SJM Masters HP 15mm Rotatable Mechanical Heart Valve as Aortic Valve Replacement Therapy
|
||
Completed |
NCT04073875 -
18F-GP1 PET-CT to Detect Bioprosthetic Aortic Valve Thrombosis
|
||
Recruiting |
NCT03121053 -
Preventing contrAst Induced Nephropathy After TranscathEter Aortic Valve Replacement
|
Phase 4 | |
Completed |
NCT02000544 -
Clinical Evaluation of a Modular Extracorporeal Circulation Circuit
|
N/A | |
Completed |
NCT02688153 -
EDWARDS INTUITY Valve System CADENCE Study
|
N/A | |
Completed |
NCT02981004 -
PAR I - Patient-to-Annulus Relation I
|
||
Recruiting |
NCT06126367 -
Assessment of Lipoprotein(a) and Endogenous Fibrinolysis in Atherosclerotic Cardiovascular Disease/Aortic Valve Disease
|