Clinical Trials Logo

Clinical Trial Summary

The goal of this multicenter prospective cohort study is to evaluate the long-term safety and efficacy of clinical outcomes of aortic valve replacement using the "TiAra" prosthesis with or without concomitant procedures. Main research objectives: 1. To analyze the short and mid-term (up to 3 years) outcome of aortic valve replacement using the "TiAra" prosthesis. 2. To study the hemodynamic characteristics of normally functioning "TiAra" prostheses in the aortic position, as well as the condition of the heart chambers in short and long-term period (up to 10 years) after the implantation. 3. To assess complications of the early and mid-term follow-up periods of aortic valve replacement using the "TiAra" prosthesis. This study does not presuppose implementation of comparison groups.


Clinical Trial Description

Cardiovascular system diseases are one of the main causes of death worldwide. Heart valve diseases are considered one of the most important issues associated with the cardiovascular system. The replacement of heart valves includes the production of prostheses that provide functional consistency with exceptionally high reliability and appropriate fatigue strength. The proposed new biological valve with a frame made of super-elastic material allows preserves the natural biomechanics of the reconstructed valve and has high biocompatibility and resistance to infection due to the use of biological material as a frame covering. The "TiAra" bioprosthetic valve has the ability to deform during the cardiac cycle in accordance with the deformations of the fibrous structures of the patients' aortic root. The implanted valve fully integrates into the native aortic root. The purpose of these clinical trials is to obtain clinical data confirming the efficacy and safety of the bioprosthesis under normal conditions in humans. The expected clinical benefit involves the treatment of valvular disease with restoration of intracardiac hemodynamics during implantation of the "TiAra" bioprosthetic valve, followed by remodeling of the heart chambers, which should lead to an improvement in heart function and quality of life of the patient. The expected risks are associated with taking anticoagulant therapy during the first three months after implantation, or as a result of prolonged anticoagulant therapy, in the presence of concomitant rhythm disturbances, and consist in the possibility of hemorrhagic or thromboembolic complications. In order to reduce the risks caused by anticoagulant therapy, it is planned to carry out measures aimed at restoring the sinus rhythm and ensuring proper control of the indicators of the blood coagulation system. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05998694
Study type Observational
Source Closed Joint-Stock Company NeoCor
Contact Alexey Evtushenko, MD,PhD
Phone +7 (3842) 64-33-08
Email ave@kemcardio.ru
Status Recruiting
Phase
Start date June 1, 2021
Completion date August 10, 2024

See also
  Status Clinical Trial Phase
Recruiting NCT04149600 - Identification of Genetic Causes of Calcific Aortic Valve Disease
Recruiting NCT06001489 - The Effects of 360-degree Virtual Reality on Pre-procedural Anxiety in Patients Awaiting Elective Cardiac Surgery Involving a Sternotomy N/A
Not yet recruiting NCT04430972 - Immune Responsiveness and Outcome After Aortic Valve Surgery (Measure)
Completed NCT02467062 - Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease. N/A
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Terminated NCT02128841 - Comparison of Antithrombotic Treatments After Aortic Valve Replacement. Rivaroxaban: A New Antithrombotic Treatment for Patients With Mechanical Prosthetic Aortic Heart Valve. Phase 2
Active, not recruiting NCT01194362 - A Study to Identify Differences in Gene Expression in Patients With Bicuspid and Tricuspid Valve Disease
Not yet recruiting NCT05975567 - Deploying Novel Imaging Modalities Towards a Three-dimensional (3D) CARDIOvascular PATHology
Recruiting NCT06025149 - The Study on the Use of "UniLine" Bioprosthesis in the Treatment of Isolated Aortic and Mitral Valve Diseases
Completed NCT05082337 - The SAVVY Guidewire in Transcatheter Aortic Valve Replacement Procedures N/A
Completed NCT05193760 - Robustness Check of Placement and Measurement Algorithms for Blood Flow Measurement on Common Carotid Artery
Not yet recruiting NCT05941455 - A Prospective Multicenter Pivotal Study to Evaluate Safety and Effectiveness of Venus-Neo Surgical Aortic Valve N/A
Active, not recruiting NCT04950192 - Philips Intracardiac Echocardiography (ICE) Clinical Registry
Active, not recruiting NCT03924661 - SJM Masters HP 15mm Rotatable Mechanical Heart Valve as Aortic Valve Replacement Therapy
Completed NCT04073875 - 18F-GP1 PET-CT to Detect Bioprosthetic Aortic Valve Thrombosis
Recruiting NCT03121053 - Preventing contrAst Induced Nephropathy After TranscathEter Aortic Valve Replacement Phase 4
Completed NCT02000544 - Clinical Evaluation of a Modular Extracorporeal Circulation Circuit N/A
Completed NCT02688153 - EDWARDS INTUITY Valve System CADENCE Study N/A
Completed NCT02981004 - PAR I - Patient-to-Annulus Relation I
Recruiting NCT06126367 - Assessment of Lipoprotein(a) and Endogenous Fibrinolysis in Atherosclerotic Cardiovascular Disease/Aortic Valve Disease