Aortic Valve Disease Clinical Trial
Official title:
DIrect Oral Anticoagulant for Antithrombotic Management Of mechaNical Aortic Valve Implanted Patients for Valvular Heart Disease Study
DIAMOND study is a national, multicentre, randomized, parallel-group, open label study in patients (aged ≥18 years) with mechanical aortic valve at least 7 days after cardiac surgery. Experimental group: Patients treated with apixaban 5 mg twice daily (BID) Active Comparator group: Patients treated with warfarin with an objective of INR target of 2.5 (range: 2.0-3.0) The Primary objective is To demonstrate that antithrombotic treatment with apixaban is non-inferior to warfarin (INR target range 2.0 - 3.0) in patients with mechanical heart valve implanted in the aortic position for at least 7 days for the primary net clinical benefit endpoint of ischemic outcomes (death, myocardial infarction, stroke, systemic embolism and valve thrombosis) and bleeding (ISTH major and non-major clinically relevant bleeding).
Antithrombotic management of patients with mechanical heart valves continues to be an important medical concern. Vitamin K antagonists (VKAs) are currently the only oral anticoagulants approved for mechanical prosthetic valve-implanted patients. As effective as these anticoagulants are, they have major drawbacks: narrow therapeutic window, variable dose-response in individuals, interaction with several foods and drugs. Achieved INR is frequently outside the target range and INR instability is a predictor of bleeding and late mortality in patients with mechanical heart valve prosthesis. Despite multiple studies that show that tissue valves have a limited durability, many patients sometimes even young choose this type of valve to avoid VKAs. In randomized studies and registries, direct oral anticoagulants (DOACs) have demonstrated their superiority to reduce bleeding in patients with non-valvular atrial fibrillation compared to VKAs with similar efficacy and are recommended as first choice in the guidelines. Apixaban has demonstrated a favorable benefit-risk profile to reduce bleeding in the different indications (ranging from 25-50%). So far, DOACs are currently contra-indicated or not indicated in patients with a mechanical prosthesis. The results of a single small-sized phase II randomized trial testing an anti-IIa drug were disappointing and anti-Xa drugs have not been appropriately evaluated in patients with a mechanical prosthesis. Only small observational series suggest encouraging results with anti-Xa DOACs. Ongoing randomized trials are conducted with DOACs compared to warfarin but the studies only include one type of mechanical aortic valve or mechanical valve in mitral position. Moreover, these studies are underpowered to completely answer the question about clinical ischemic and bleeding outcomes. Then, there is an unmet clinical need for an alternative to VKAs, such as an anti-Xa DOAC like apixaban, as anticoagulation in patients with a mechanical aortic prosthetic valve. The purpose of this study is to determine if patients with mechanical prosthetic valve in the aortic position at least 7 days after cardiac surgery can be maintained effectively with a better safety (net clinical benefit) on apixaban compared to warfarin. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04149600 -
Identification of Genetic Causes of Calcific Aortic Valve Disease
|
||
Recruiting |
NCT06001489 -
The Effects of 360-degree Virtual Reality on Pre-procedural Anxiety in Patients Awaiting Elective Cardiac Surgery Involving a Sternotomy
|
N/A | |
Not yet recruiting |
NCT04430972 -
Immune Responsiveness and Outcome After Aortic Valve Surgery (Measure)
|
||
Completed |
NCT02467062 -
Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease.
|
N/A | |
Not yet recruiting |
NCT02221921 -
Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI
|
N/A | |
Terminated |
NCT02128841 -
Comparison of Antithrombotic Treatments After Aortic Valve Replacement. Rivaroxaban: A New Antithrombotic Treatment for Patients With Mechanical Prosthetic Aortic Heart Valve.
|
Phase 2 | |
Active, not recruiting |
NCT01194362 -
A Study to Identify Differences in Gene Expression in Patients With Bicuspid and Tricuspid Valve Disease
|
||
Not yet recruiting |
NCT05975567 -
Deploying Novel Imaging Modalities Towards a Three-dimensional (3D) CARDIOvascular PATHology
|
||
Recruiting |
NCT06025149 -
The Study on the Use of "UniLine" Bioprosthesis in the Treatment of Isolated Aortic and Mitral Valve Diseases
|
||
Completed |
NCT05082337 -
The SAVVY Guidewire in Transcatheter Aortic Valve Replacement Procedures
|
N/A | |
Completed |
NCT05193760 -
Robustness Check of Placement and Measurement Algorithms for Blood Flow Measurement on Common Carotid Artery
|
||
Not yet recruiting |
NCT05941455 -
A Prospective Multicenter Pivotal Study to Evaluate Safety and Effectiveness of Venus-Neo Surgical Aortic Valve
|
N/A | |
Active, not recruiting |
NCT04950192 -
Philips Intracardiac Echocardiography (ICE) Clinical Registry
|
||
Active, not recruiting |
NCT03924661 -
SJM Masters HP 15mm Rotatable Mechanical Heart Valve as Aortic Valve Replacement Therapy
|
||
Completed |
NCT04073875 -
18F-GP1 PET-CT to Detect Bioprosthetic Aortic Valve Thrombosis
|
||
Recruiting |
NCT03121053 -
Preventing contrAst Induced Nephropathy After TranscathEter Aortic Valve Replacement
|
Phase 4 | |
Completed |
NCT02000544 -
Clinical Evaluation of a Modular Extracorporeal Circulation Circuit
|
N/A | |
Completed |
NCT02981004 -
PAR I - Patient-to-Annulus Relation I
|
||
Completed |
NCT02688153 -
EDWARDS INTUITY Valve System CADENCE Study
|
N/A | |
Recruiting |
NCT06126367 -
Assessment of Lipoprotein(a) and Endogenous Fibrinolysis in Atherosclerotic Cardiovascular Disease/Aortic Valve Disease
|