Clinical Trials Logo

Clinical Trial Summary

TAVR patients exhibiting post-procedural residual AR had higher mortality and hospitalization rates due to heart failure, with the extent of this association increasing proportionally to the severity of the regurgitation. Optimizing transcatheter valve performance by intra-procedural hemodynamic evaluation of AR and residual transvalvular gradient remains of high clinical importance.


Clinical Trial Description

Continuous technological development and procedural refinements are important to further reduce TAVR peri-procedural complications, facilitate the minimalist strategy and improve clinical outcomes following TAVR. Residual aortic regurgitation (AR) has been one of the main drawbacks of TAVR. TAVR patients exhibiting post-procedural residual AR had higher mortality and hospitalization rates due to heart failure, with the extent of this association increasing proportionally to the severity of the regurgitation. Various actions could be undertaken to minimize AR and its consequences, either intraprocedural (balloon post-dilation, implantation of a second valve) or during follow-up (diuretic treatment, closest clinical follow-up or percutaneous leakage closure). Thus, an accurate diagnosis of the presence and severity of residual AR post-TAVR is key to implement the proper measures and optimize clinical outcomes. The use of cardiac imaging remains the gold standard for evaluating AR post-TAVR, limitations of contrast amount along with the subjectivity of AR evaluation by aortic angiography, and the challenges of echocardiography at the time of the TAVR procedure represent a significant drawback. Thus, alternative tools for evaluating the presence and severity of AR would be very helpful in this setting. Current data supports the implementation of hemodynamic measurements during TAVR procedures in order to improve the clinical decision-making process following valve implantation. However, these actions entail an inherent risk associated with the exchange of catheter-wires. The use of a support guidewire with pressure measurement capabilities would facilitate the hemodynamic evaluation of transcatheter valve performance in a safer and more rapid manner. The new SAVVY guidewire, with both dedicated pacing properties and allowing a continuous hemodynamic pressure monitoring during the procedure, is a unique system in the field and may represent an important step forward in the process of optimizing the TAVR procedure while facilitating procedural steps. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05082337
Study type Interventional
Source Institut universitaire de cardiologie et de pneumologie de Québec, University Laval
Contact
Status Completed
Phase N/A
Start date October 8, 2021
Completion date December 28, 2021

See also
  Status Clinical Trial Phase
Completed NCT03186339 - Validation of the "TASQ" in Patients Undergoing SAVR or TF-TAVI
Recruiting NCT03549559 - Imaging Histone Deacetylase in the Heart N/A
Terminated NCT02854319 - REpositionable Percutaneous Replacement of NatIve StEnotic Aortic Valve Through Implantation of LOTUS EDGE Valve System N/A
Recruiting NCT05601453 - The ReTAVI Prospective Observational Registry
Withdrawn NCT05481814 - CPX in Paradoxical Low Flow Aortic Stenosis
Completed NCT02241109 - Predicting Aortic Stenosis Progression by Measuring Serum Calcification Propensity N/A
Completed NCT01700439 - Surgical Treatment of Aortic Stenosis With a Next Generation, Rapid Deployment Surgical Aortic Valve N/A
Recruiting NCT04429035 - SLOW-Slower Progress of caLcificatiOn With Vitamin K2 N/A
Completed NCT04103931 - Impact of a Patient Decision Aid for Treatment of Aortic Stenosis N/A
Completed NCT03950440 - Assessing the Incidence of Postoperative Delirium Following Aortic Valve Replacement
Active, not recruiting NCT02661451 - Transcatheter Aortic Valve Replacement to UNload the Left Ventricle in Patients With ADvanced Heart Failure (TAVR UNLOAD) N/A
Completed NCT02792452 - Clinical Value of Stress Echocardiography in Moderate Aortic Stenosis
Completed NCT02847546 - Evaluation of the BARD® True™ Flow Valvuloplasty Perfusion Catheter for Aortic Valve Dilatation N/A
Completed NCT02758964 - Evaluation of Cerebral Thrombembolism After TAVR
Not yet recruiting NCT02541877 - Sizing-sTrategy of Bicuspid AoRtic Valve Stenosis With Transcatheter Self-expandable Valve Phase 3
Not yet recruiting NCT02536703 - Safety and Efficacy of Lotus Valve For TAVI In Patients With Severe Aortic Stenosis In Chinese Population Phase 3
Completed NCT02249000 - BIOVALVE - I / II Clincial Investigation N/A
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Active, not recruiting NCT02080299 - Protection by Remote Ischemic Preconditioning During Transcatheter Aortic Valve Implantation Phase 2
Terminated NCT01939678 - Characterization and Role of Mutations in Sodium-phosphate Cotransporters in Patients With Calcific Aortic Valve Disease