Aortic Valve Disease Clinical Trial
Official title:
Ross for Valve Replacement in AduLts Trial
This study evaluates two methods of aortic heart valve replacement in adults aged 18-60, the Ross procedure versus conventional aortic valve replacement using a biologic or mechanical heart valve. The Ross procedure replaces a patient's diseased aortic valve with his/her own pulmonary valve and uses a donor valve in the pulmonary position which receives less stress than the aortic valve. Mechanical valves tend to form blood clots so they need long-term blood thinners that increase risk of bleeding and lower quality of life. Animal tissue valves reduce clotting and bleeding risks but wear out sooner and shorten patient life-span.
Heart valves help control blood flow through the heart and, if diseased, may need to be replaced. After having a heart valve replaced, patients have a higher risk of death than people who have not had a valve replaced. In young adult patients, replacing the aortic heart valve with a mechanical valve halves their life-span compared to other people their age. Mechanical valves tend to form blood clots so they need long-term blood thinners that increase risk of bleeding and lower quality of life. Animal tissue valves reduce clotting and bleeding risks but wear out sooner and shorten patient life-span. An operation, called the Ross procedure, replaces a patient's diseased aortic valve with his/her own pulmonary valve and uses a donor valve in the pulmonary position which receives less stress than the aortic valve. The Ross procedure aims to improve valve durability with less clotting, avoiding use of blood thinners. Patients and physicians need a large, high-quality study comparing the Ross procedure and standard valve replacement to know if either approach is better. The investigators will perform a 3-year feasibility study in seven sites, in Canada and abroad, to test the study design and ability to do a larger, conclusive study comparing the impact of the Ross procedure to standard valve replacement on survival without valve-related life-threatening complications. Patients will be randomized, like flipping a coin, to receive the Ross or standard valve surgery. The goals are 1) to evaluate if the investigators can recruit 6 patients per site per year, 2) to test if the assigned procedure is performed in over 90% of study patients, and 3) to see how many mechanical vs. tissue valves are used in the standard valve group. Patients eligible but not enrolled in the trial will be asked if the investigators can collect some data on how they do after their surgery. If the investigators show the study is feasible, they will proceed to the full study and will include the feasibility patients in the full study. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04149600 -
Identification of Genetic Causes of Calcific Aortic Valve Disease
|
||
Recruiting |
NCT06001489 -
The Effects of 360-degree Virtual Reality on Pre-procedural Anxiety in Patients Awaiting Elective Cardiac Surgery Involving a Sternotomy
|
N/A | |
Not yet recruiting |
NCT04430972 -
Immune Responsiveness and Outcome After Aortic Valve Surgery (Measure)
|
||
Completed |
NCT02467062 -
Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease.
|
N/A | |
Not yet recruiting |
NCT02221921 -
Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI
|
N/A | |
Terminated |
NCT02128841 -
Comparison of Antithrombotic Treatments After Aortic Valve Replacement. Rivaroxaban: A New Antithrombotic Treatment for Patients With Mechanical Prosthetic Aortic Heart Valve.
|
Phase 2 | |
Active, not recruiting |
NCT01194362 -
A Study to Identify Differences in Gene Expression in Patients With Bicuspid and Tricuspid Valve Disease
|
||
Not yet recruiting |
NCT05975567 -
Deploying Novel Imaging Modalities Towards a Three-dimensional (3D) CARDIOvascular PATHology
|
||
Recruiting |
NCT06025149 -
The Study on the Use of "UniLine" Bioprosthesis in the Treatment of Isolated Aortic and Mitral Valve Diseases
|
||
Completed |
NCT05082337 -
The SAVVY Guidewire in Transcatheter Aortic Valve Replacement Procedures
|
N/A | |
Completed |
NCT05193760 -
Robustness Check of Placement and Measurement Algorithms for Blood Flow Measurement on Common Carotid Artery
|
||
Not yet recruiting |
NCT05941455 -
A Prospective Multicenter Pivotal Study to Evaluate Safety and Effectiveness of Venus-Neo Surgical Aortic Valve
|
N/A | |
Active, not recruiting |
NCT04950192 -
Philips Intracardiac Echocardiography (ICE) Clinical Registry
|
||
Active, not recruiting |
NCT03924661 -
SJM Masters HP 15mm Rotatable Mechanical Heart Valve as Aortic Valve Replacement Therapy
|
||
Completed |
NCT04073875 -
18F-GP1 PET-CT to Detect Bioprosthetic Aortic Valve Thrombosis
|
||
Recruiting |
NCT03121053 -
Preventing contrAst Induced Nephropathy After TranscathEter Aortic Valve Replacement
|
Phase 4 | |
Completed |
NCT02000544 -
Clinical Evaluation of a Modular Extracorporeal Circulation Circuit
|
N/A | |
Completed |
NCT02688153 -
EDWARDS INTUITY Valve System CADENCE Study
|
N/A | |
Completed |
NCT02981004 -
PAR I - Patient-to-Annulus Relation I
|
||
Recruiting |
NCT06126367 -
Assessment of Lipoprotein(a) and Endogenous Fibrinolysis in Atherosclerotic Cardiovascular Disease/Aortic Valve Disease
|