Clinical Trials Logo

Clinical Trial Summary

Bicuspid Aortic Valve (BAV) disease is a common cardiac anomaly that is associated with valvular abnormalities, both stenosis and regurgitation, and aortopathy. It is also shown to play role in abnormal aortic distensibility and stiffness with impairment of aortic elasticity and Left ventricular dysfunction. Mechanism of aortopathy is complex and is not understood completely. In a recent study podocan is found in extracellular matrix (ECM) of human aorta and is found to be accumulated in human abdominal aortic aneurysms. There is no current effective therapy that can alter the progression of aortic dilatation in bicuspid valve disease. Aortic surgery and aortoplasty is the only treatment in severely dilated aorta and aortic dissection. In this study the aim is to investigate the association between podocan and Wnt pathway in development and pathogenesis of aortopathy. This could provide more effective and physiological understanding of disease process and potential target in prevention and treatment for aortopathy.


Clinical Trial Description

Patients with known BAV will be enrolled in two inclusion criteria categories: - Group A: Patients who are scheduled to have a cardiac MRI Procedures for Group A: MRI will be used as a standard procedure to confirm the morphology of bicuspid valve especially in uncertain cases and to do accurate aortic measurements. Patients who agree to participate will provide informed consent prior to their cardiac MRI/CT. A 6 minute walk test to measure baseline functional status will be performed after consent. All patients having a cardiac MRI/CT have an IV line placed as normal procedure. When then line has been placed, prior to contrast infusion a blood sample will be collected to test for circulatory Podocan and Wnt pathway molecules. At 24 months post procedure the following information will be collected from the participants' charts for endpoint analysis: - All cause mortality - Hospital admissions for Aortic dissection, Congestive heart failure, endocarditis or cardiac death - Valve replacement or aortic graft surgery - Group B: Patients who have already had an MRI within the past year Procedures for Group B: MRI will be used as a standard procedure to confirm the morphology of bicuspid valve especially in uncertain cases and to do accurate aortic measurements. Patients who agree to participate will report to the Clinical Research Division (CRD ) for a research visit to enroll in the study. At this visit, the patient will provide informed consent, complete a 6 minute walk test to measure baseline functional status , and will have blood drawn by venipuncture to obtain a blood sample to test for circulatory Podocan and Wnt pathway molecules. At 24 months post procedure the following information will be collected from the participants' charts for endpoint analysis: - All cause mortality - Hospital admissions for Aortic dissection, Congestive heart failure, endocarditis or cardiac death - Valve replacement or aortic graft surgery All patients who do undergo valve replacement or aortic graft surgery within the 24 month follow up period, will have their valve tissue samples analyzed for podocan levels. These tissues are removed as a routine part of the surgery and sent to the clinical laboratory at Bassett. The number of tissue samples collected during this procedure can range from one to four based on the exact nature and location of the aortic pathology. The Bassett Clinical Lab will prepare additional paraffin blocks and slides of the tissue for the research study. A blood sample will also be taken at the time of the patient's post-op MRI to test for circulatory Podocan and Wnt pathway molecules. This usually occurs about 6-9 months after surgery. It is expected that 100 participants will be enrolled in the study over 18 months. This is a sample size of convenience for this pilot study based the current volume of patients undergoing cardiac MRI/CT for evaluation of valvular disease. Of these 100 patients, it is estimated that 25 will undergo surgery as described above within the study period. Baseline analysis will be performed to study the association between circulatory Podocan and Wnt regulatory molecules (Wnt-1, Wnt-3, Dkk-1, WIF-1, sFRP-1, sFRP-3) measured by ELISA in peripheral blood and tissue samples of aortic root/ascending aorta. Each participant's chart will be reviewed at the time of enrollment and the following variables will be abstracted from the medical record: - age, - gender, - ethnicity, - Most recent Ht, Wt, BP, HR - BMI - Tobacco use/history - Alcohol use/ history - Comorbidities - HTN - Hyperlipidemia - Diabetes - CKD - Cancer - CAD - Info from previous echocardiogram: - Ejection fraction - Valve area - Gradient - Info from previous cardiac cath (if done): - Presence/absence of coronary stenosis - Location and degree of stenosis - Aortic valve area - Calculation of valve area - Info from previous ECG: - Rhythm - LVH - Medications - Laboratory data: - Lipids - Chemistries - CBC - HgA1C - Troponin - BNP ;


Study Design


Related Conditions & MeSH terms


NCT number NCT02806310
Study type Observational [Patient Registry]
Source Bassett Healthcare
Contact
Status Completed
Phase
Start date June 2016
Completion date December 2020

See also
  Status Clinical Trial Phase
Recruiting NCT04149600 - Identification of Genetic Causes of Calcific Aortic Valve Disease
Recruiting NCT06001489 - The Effects of 360-degree Virtual Reality on Pre-procedural Anxiety in Patients Awaiting Elective Cardiac Surgery Involving a Sternotomy N/A
Not yet recruiting NCT04430972 - Immune Responsiveness and Outcome After Aortic Valve Surgery (Measure)
Completed NCT02467062 - Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease. N/A
Not yet recruiting NCT02221921 - Safety and Efficacy Study of MicroPort's Transcatheter Aortic Valve and Delivery System for TAVI N/A
Terminated NCT02128841 - Comparison of Antithrombotic Treatments After Aortic Valve Replacement. Rivaroxaban: A New Antithrombotic Treatment for Patients With Mechanical Prosthetic Aortic Heart Valve. Phase 2
Active, not recruiting NCT01194362 - A Study to Identify Differences in Gene Expression in Patients With Bicuspid and Tricuspid Valve Disease
Not yet recruiting NCT05975567 - Deploying Novel Imaging Modalities Towards a Three-dimensional (3D) CARDIOvascular PATHology
Recruiting NCT06025149 - The Study on the Use of "UniLine" Bioprosthesis in the Treatment of Isolated Aortic and Mitral Valve Diseases
Completed NCT05082337 - The SAVVY Guidewire in Transcatheter Aortic Valve Replacement Procedures N/A
Completed NCT05193760 - Robustness Check of Placement and Measurement Algorithms for Blood Flow Measurement on Common Carotid Artery
Not yet recruiting NCT05941455 - A Prospective Multicenter Pivotal Study to Evaluate Safety and Effectiveness of Venus-Neo Surgical Aortic Valve N/A
Active, not recruiting NCT04950192 - Philips Intracardiac Echocardiography (ICE) Clinical Registry
Active, not recruiting NCT03924661 - SJM Masters HP 15mm Rotatable Mechanical Heart Valve as Aortic Valve Replacement Therapy
Completed NCT04073875 - 18F-GP1 PET-CT to Detect Bioprosthetic Aortic Valve Thrombosis
Recruiting NCT03121053 - Preventing contrAst Induced Nephropathy After TranscathEter Aortic Valve Replacement Phase 4
Completed NCT02000544 - Clinical Evaluation of a Modular Extracorporeal Circulation Circuit N/A
Completed NCT02688153 - EDWARDS INTUITY Valve System CADENCE Study N/A
Completed NCT02981004 - PAR I - Patient-to-Annulus Relation I
Recruiting NCT06126367 - Assessment of Lipoprotein(a) and Endogenous Fibrinolysis in Atherosclerotic Cardiovascular Disease/Aortic Valve Disease