Aortic Aneurysm Clinical Trial
Official title:
The Use of CO2 Automated Angiographies Combined With Fusion Imaging to Obtain Zero- or Near Zero- Contrast FEVAR for Complex Aortic Aneurysms.
Fenestrated endovascular aneurysm repair (FEVAR) is an established technique used to treat complex aortic aneurysms (TAAAs), with satisfactory early and midterm results. Postoperative renal function worsening is a common adverse event after FEVAR of complex aneurysms and is associated with prolonged hospital stay, higher morbidity, and long-term mortality in the peri-operative period and during follow-up. One of the more common causes of renal function worsening is contrast-induced nephropathy resulting from the use of iodinated contrast medium (ICM). Automated carbon dioxide (CO2) angiography has been proposed as an alternative to ICM for standard endovascular aneurysm repair (EVAR) in consideration of its absence of nephrotoxicity that can be of further help in preserving renal function. In adjunct, hybrid room and fusion imaging (FI) technologies are useful tools to reduce intraoperative contrast medium and fluoroscopy time. In literature there are few reports regarding the use of CO2 for fenestrated endografting repair of complex aortic aneurysms. The aim of the present study is to report the possibility to combine the use of automated CO2 angiographies and Fusion Imaging to obtain zero- or near zero- contrast FEVAR for complex aortic aneurysms.
Fenestrated endovascular aneurysm repair (FEVAR) is an established technique used to treat juxtarenal and pararenal abdominal aortic aneurysms (AAAs) and type IV thoracoabdominal aortic aneurysms (TAAAs), as demonstrated by early and midterm literature results. Postoperative renal function worsening is a common adverse event after FEVAR of complex aneurysms and is associated with prolonged hospital stay, higher morbidity, and long-term mortality in the peri-operative period and during follow-up. Renal function may worsen after FEVAR because of a variety of factors, but one of the more common causes of renal function worsening is contrast-induced nephropathy resulting from the use of iodinated contrast medium (ICM). Automated CO2 angiography has been proposed as an alternative to ICM for standard endovascular aneurysm repair (EVAR) in consideration of its absence of nephrotoxicity that can be of further help in preserving renal function. In adjunct, hybrid room and fusion imaging (FI) technologies, based on a three-dimensional preoperative computed tomography angiography (CTA) image over-laid on a two-dimensional live fluoroscopy image, are useful tools to reduce intraoperative contrast medium and fluoroscopy time. The aim of the present study is to report the possibility to combine the use of automated CO2 angiographies and Fusion Imaging to obtain zero- or near zero- contrast FEVAR for complex aortic aneurysms. ENDPOINTS Early: - Technical success (defined as correct endograft deployment with stenting and patency of all planned target visceral vessels (TVVs) and absence of type I and type III endoleaks, iliac leg stenosis or kinking and mortality at 24 hours) - in-hospital/30-day reintervention and mortality - perioperative renal function worsening (according to the RIFLE, Risk, Injury, Failure, Loss of kidney function, End-stage renal disease, criteria) Follow-up: - Freedom from TVVs instability - Survival - Freedom from reintervention - Freedom from renal function worsening CO2 Injection protocol Diagnostic CO2 angiographies are performed in the anteroposterior and 90-degree lateral projections from a 6F sheet, positioned in the pararenal aorta, by an automated CO2 injector (Angiodroid; San Lazzaro, Bologna, Italy). The FI/VesselNavigator is optimized with these two CO2 angiography images and the TVV origins. The injection pressure and volume are usually set at 650 mmHg and 100 ml, respectively. Carbon dioxide angiographies are repeated step by step after endograft introduction and during endograft deployment to adjust the endograft's position according to fusion images. To evaluate cannulation and bridging stentgraft deployment in each TVVs CO2 angiographies are performed with the 6F sheet for superior mesenteric artery and, for the other TVVs, with selective angiographies through the TVVs sheet. In this case, the injection pressure is set at 300 mmHg while the injection volume is set at 40 mL. The angiographic shots required to deploy the bifurcated graft and the contralateral iliac leg are usually performed through an automated CO2 injection from the femoral sheaths. Completion angiography is performed through 6F sheet positioned in the proximal portion of the endograft, in both anteroposterior and lateral views. FOLLOW-UP 30-day: CTA scan + blood tests 3 months: duplex ultrasound (DUS) or CTA scan (in case of any doubt) + blood tests 6 months: DUS + blood tests 12 months: CTA scan + blood tests During the follow-up, clinical evaluations will be performed as per standard clinical practice for patients with this condition. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT04149600 -
Identification of Genetic Causes of Calcific Aortic Valve Disease
|
||
Enrolling by invitation |
NCT04035356 -
HAART Annuloplasty Device Valve Repair Registry
|
||
Recruiting |
NCT02729064 -
Intraoperative Nasal Insulin Effect on Plasma and CSF Insulin Concentration and Blood Glucose
|
Phase 1 | |
Completed |
NCT02467062 -
Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease.
|
N/A | |
Completed |
NCT02283307 -
Dual Energy CT Urography With Reduced Iodinated Contrast
|
N/A | |
Completed |
NCT01678261 -
X-chromosome Inactivation, Epigenetics and the Transcriptome
|
N/A | |
Terminated |
NCT01055275 -
Cook Iliac Branch Graft Post-market Registry
|
N/A | |
Completed |
NCT00615888 -
Fast Track Management in Elective Open Infrarenal Aortic Aneurysm Repair
|
N/A | |
Completed |
NCT03510793 -
Microcirculation and Anesthesia in Vascular Surgery
|
||
Completed |
NCT03207568 -
RE-GENERATION: The Safety and Performance of the Relay Pro and Relay NBS Pro Stent-graft Devices in the European Union (EU)
|
N/A | |
Recruiting |
NCT05073991 -
Incidence of Mortality and Complications After Lung Surgery, Open Thoracic Aortic Repair, TEVAR, EVAR.
|
||
Not yet recruiting |
NCT01918969 -
Reference Values of Circulating Endothelial Progenitor Cells
|
N/A | |
Completed |
NCT02000544 -
Clinical Evaluation of a Modular Extracorporeal Circulation Circuit
|
N/A | |
Not yet recruiting |
NCT01918982 -
Circulating Endothelial Progenitor Cells and Aortic Aneurysm
|
N/A | |
Completed |
NCT01256372 -
An Trial of Two Dosing Regimens of AP214 for the Prevention of Kidney Injury in Patients Undergoing Cardiac Surgery
|
Phase 2 | |
Recruiting |
NCT00661518 -
PET/CT Imaging of Aneurysm Wall Inflammation
|
N/A | |
Completed |
NCT00094575 -
Standard Open Surgery Versus Endovascular Repair of Abdominal Aortic Aneurysm (AAA)
|
Phase 4 | |
Recruiting |
NCT04471909 -
NEXUS Aortic Arch Clinical Study to Evaluate Safety and Effectiveness
|
N/A | |
Recruiting |
NCT05603520 -
Phenotyping Heterogeneity and Regionality of the Aorta
|
||
Completed |
NCT03727542 -
Influence of Short AV Delay Permanent Pacing on Matrix Metalloproteinase Levels
|
N/A |