Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT05287828
Other study ID # ASMOT
Secondary ID
Status Completed
Phase
First received
Last updated
Start date June 16, 2022
Est. completion date May 4, 2023

Study information

Verified date June 2023
Source Nurea
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

The treatment of aortic aneurysms is today based on different indicators (diameters, lengths, angles, volumes of the arteries) measured on CT scan images. Several indicators are time consuming and complicatated to measure. They demand training and practice. Nurea is developing a software for automatic measurement of these indicators, PRAEVAorta® 2, to facilitate and assist the physician in his clinical routine. The purpose of this study is to compare the analysis realised by the software PRAEVAorta® 2 with the analysis realised by the healthcare professional on retrospective CT scan images. Contrasted and non-contrasted, pre-operation or post-operation CT scans from 50 patients will be analysed. The main objectif is to validate the accuracy of the software by demonstrating its adequacy to the standard method of analysis. The second objectives are the following: - Evaluate the security of the software PRAEVAorta® 2 - Evaluate the unanticipated risks related to the use of the software - Validate the accessory PRAEVAorta® Web We make the following assumption : 90% of the patients show 90% of adequacy to the healthcare professional analysis


Description:

Control and quality assurance will be applied in the investigation site. The monitor mandated by the sponsor Nurea will ensure the follow-up and the proper completion of the study, the collection of data in writing, their documentation, recording and report, in accordance with the procedures in place and in accordance with good clinical practice as well as the laws and regulations in force. Quality control visits realised at regular intervals will be realised by the monitor. During those visits, the following elements could be demanded: - Informed consent forms, information note - Respect of the plan of the study and the procedures defined in it - Quality of the data collected in the Case Report Form (CRF): accuracy, missing data, consistency of data with the "source" documents (medical file, appointment book, originals of laboratory results). - Management of any products - Security data All contacts made will give rise to a specific written report Three type of visits (quality control) will be realised: - The initiation visit (realised in person) will concern every person potentially involved in the investigation. This visit will be about presenting the plan, redefine inclusion objectives, recall everyone's responsibility and the regulation, as well as answering question. - The monitoring visits will be realised by the monitor after the first inclusion to ensure the respect of the plan and the regulation, as well as the quality of the collected data. Those visits will be realised every 2weeks, but the frequency can vary regarding the complexity of the study, of the number and the pace of inclusions. Therefore, there will be at least one visit per month. - The close-out visit will be realised after the last data have been collected. The purpose of this visit is to verify the quality of the collected data, to update the documents before archiving. In addition to these on-site travels, a regular monitoring over the phone will be realised in order to best support the participating physicians throughout the study. These quality controls are supplemented by regular follow-up audits in order to evaluate the quality of collected data and to crop the study. An audit may be conducted at any time by persons appointed by the sponsor and independent of the persons conducting the research. Its purpose is to verify the participants' safety and respect for their rights, compliance with applicable regulations and the reliability of data. An inspection can also be carried out by a competent authority (ANSM for France or EMA in the context of a European study, for example). The audit, as well as the inspection, can be applied at all stages of the research, from the development of the protocol to the publication of the results and the classification of the data used or produced as part of the research. Data management Access to data Only participating physicians and the monitor (or clinical research staff) will have access to source files during the monitoring visits. During quality control visits, the principal investigator must make the following documents available: - informed consent, - briefing notes, - observation notebooks, - source documents (medical records, appointment books, etc.) In accordance with the law in force, patients have a right of access to their medical file. According to the law of January 2002, patients will be told where they can inquire about the results of the study. Guidelines for collecting data The term "Case Report Form (CRF)" designates any document whatever its support (for example paper, optical, magnetic or electronic) intended to collect in writing all the information required by the protocol concerning each person who is suitable for research and to be sent to the sponsor. All the information required by the protocol must be recorded in case report forms and an explanation must be provided for any missing data. The data will have to be collected as and when they are obtained and transcribed in these notebooks in a clear and legible way. It is the responsibility of the investigator to complete the CRF, but he may delegate this task to the clinical trial technicians or to the research nurse, provided that he has previously completed a task delegation form. Data collection will be done using e-CRF that will include patient characteristics and study data. The patient will be identified by an alphanumeric code and the data concerning him/her will be anonymized in the form. The code will be reported on all pages of the observation book. Modification of e-CRF data Corrections of errors which have occurred in an e-CRF will be carried out via the correction module thereof, and must be dated, initialed, and justified. The copies of the observation notebooks will be kept for at least 15 years on the investigation site while the original copy, once the quality control has been carried out, will be archived by the sponsor for the same duration. Standard operating procedures Investigators will determine whether patients meet the inclusion criteria, and whether the use of one or the other device will bring them beneficial results. Screening / pre-selection The selection of the patients is realised by the principal investigator. A first screening of the patient that could be included in the study is realised. To be pre-included, those patients shall: 1. respect the selection criteria (inclusion and exclusion criteria), 2. have given their consent form by non-opposition 3. Have been treated and /or followed by the hospital The discrimination of the group of patients is carried out according to the list above. Reception of the consent form / inclusion The consent form is obtained by non-opposition. The information note and consent form are sent to the pre-selected patient. After one month without any manifestation (refusal) from the patient, the consent is considered as acquired. The inclusion is validated when all data (cited above) are registered in the e-CRF. When the consent of the patient has been received, the following data are registered in the e-CRF: - Demographic data: age, gender - Scan references: scan manufacturer, contrasted or not, pre- or post-operation scan, scan date - Investigation data: Patient number, date of signature of the consent - Images data: Pre-operation scan, post-operation scan The inclusion is validated when all data (cited above) are registered in the e-CRF. Sample size assessment The number of patients needed is calculated to answer the main objective of this study which is the validation of the de vice PRAEVAorta® 2. The study realised on the first version of the medical device PRAEVAorta® has shown a proportion of 93% of patient with measures calculated by the software in adequation with the measures realised following the standard method of analysis (ratio ≥ 90%). Because the new version of the software PRAEVAorta® 2 has been improved, we expect to observe the same proportion. Patient number calculation: Hypotheses are the following: H0: The proportion of patients with an absolute mean discrepancy > 5mm is 90% H1: The proportion of patient with an absolute mean discrepancy ≤ 5mm is strictly over 90% For this statistical analysis, variables are quantitative: aorta measurements. We consider over here the proportion of patients per sub-group who have as less or greater than 90%. Comparison of two proportions: a theoretical proportion with an observed proportion The theoretical proportion ϕ0 is 90% n=([1,96(φ0(1-φ0))^0,5 +u2β(φ(1-φ))^0,5]^2)/([φ0-φ]^2)=32 For security reasons and to anticipate any problem we choose to include approximately 25% more subjects. Therefore, the total of patient is 40. We add 15 additional patients to meet the ancillary objective of evaluating anteroposterior migration of stents. The total is then 65 patients. Patients will be devided in 4 groups related to the type of scan analysed Images' analysis Pseudonymised pre-operation and post-operation thin-sliced CT images in DICOM format will be analysed. This study is design in two parts: Part 1: Validation of the software PRAEVAorta® 2 on 40 patients (principal objective). The automatic measurements are compared to the physician measurements. Procedure to follow: Step 1. Inclusion and exclusion criteria validation Step 2. Demographic data and scanner references collection Step 3. CT scans (in DICOM format) collection Step 4. First Randomisation of the subjects' order Step 5. Determination of the measures by the physician with the standard method Step 6. Second randomisation of the subjects' order Step 7. Software analysis of the images with PRAEVAorta® Suite and Physician trust opinion In step 7, physicians will have to indicate if, based on the report generated by PRAEVAorta® 2, they trust the software measures or they do not, in order to validate clinical safety. All data will be written in the e-CRF. The comparison of data will be done during the statistical analysis. The occurrence of device deficiencies will also be notified in the e-CRF. A Mid-term report will be written by the end of part 1. Part 2: Post-op follow-up of antero-posterior migration of stents and evaluation of the risk of endoleaks (secondary objective) The antero-posterior migration of stents will be analysed thanks to the software analysis. This part is realised on post-op CT scan of 50 patients who have undergone a EVAR surgery. The 50 patients are composed of the 25 patients with an AAA, included in part 1 with 25 more in order to have more significant results. Step 1. Inclusion and exclusion criteria validation for the 25 more patients Step 2. Demographic data and scanner references collection Step 3. CT scans (in DICOM format) collection Step 4. Software analysis of the images with PRAEVAorta® Suite All data will be written in the eCRF. The comparison of data will be done during the statistical analysis. The occurrence of device deficiencies will also be notified in the eCRF. The final report will be written when both part of the study are realised. Statistics: Aggregated data analysed as treated and per subgroup. Descriptive analysis - Pearson's coefficient correlation - Absolute mean discrepancy per measurements - Global mean and standard deviation per measurement endpoint - Ratio for a measure - Maximum aortic diameter ratio - Computational analysis time The duration of the semi-automatic segmentation manually corrected by the 2 surgeons was reported and compared to the fully automatic method. - Detectable and non-detectable error rate for safety evaluation - Calculation of false positive, false negative, sensibility, specificity, positive predictive values, negative predictive values and likelihood ratio (LR+ and LR-). Inferential analysis Objective: comparing an observed proportion p1 with a theoretical proportion p0 p1: proportion of adequate data p0: theoretical proportion: 90% A one-sided right test will be realised to evaluate the comparison Evaluation criteria: Principal criteria: • 90% of the patients shaw 90% of adequacy. Secondary criteria: Evaluation of the measurements and the segmentations: - The mean discrepancy shall be ≤ 5mm - Pearson correlation shall be ≥ 90% Evaluation of risks: - Unanticipated risks should not be critical Evaluation of the security - The detectable error rate shall be ≥ 95% - The non-detectable error rate shall be ≤ 5% Evaluation of PRAEVAorta® Web - No critical bug No critical unanticipated risks


Recruitment information / eligibility

Status Completed
Enrollment 65
Est. completion date May 4, 2023
Est. primary completion date September 21, 2022
Accepts healthy volunteers Accepts Healthy Volunteers
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Male or female =18 years of age - Thoraco-abdominal Aneurysm - Thoracic aortic aneurysm - Or Infra-renal abdominal aortic aneurysm - Or Juxta renal abdominal aortic aneurysm - With or without calcification - With or without stent For part 2: patient treated by endurant (Medtronic) with sideways displacement during follow-up (more than 5mm) Exclusion Criteria: Patients with - Ruptured aneurysms, - Aortic dissections.

Study Design


Related Conditions & MeSH terms


Intervention

Other:
Surgeons CT scan analysis
Surgeons extract indicators using standard methods of analysis
Device:
PRAEVAorta CT scan analysis
CT scans are analysed using PRAEVAorta Suite which is composed of the software PRAEVAorta 2 and PRAEVAorta Web. Indicators extraction is fully automatic.

Locations

Country Name City State
France Centre Hospitalier Universitaire Jean Minjoz Besançon

Sponsors (1)

Lead Sponsor Collaborator
Nurea

Country where clinical trial is conducted

France, 

References & Publications (46)

Ahmed S, Zimmerman SL, Johnson PT, Lai H, Kawamoto S, Horton KM, Fishman EK. MDCT interpretation of the ascending aorta with semiautomated measurement software: improved reproducibility compared with manual techniques. J Cardiovasc Comput Tomogr. 2014 Mar-Apr;8(2):108-14. doi: 10.1016/j.jcct.2013.12.009. Epub 2014 Jan 11. — View Citation

Ashton HA, Buxton MJ, Day NE, Kim LG, Marteau TM, Scott RA, Thompson SG, Walker NM; Multicentre Aneurysm Screening Study Group. The Multicentre Aneurysm Screening Study (MASS) into the effect of abdominal aortic aneurysm screening on mortality in men: a randomised controlled trial. Lancet. 2002 Nov 16;360(9345):1531-9. doi: 10.1016/s0140-6736(02)11522-4. — View Citation

Beales L, Wolstenhulme S, Evans JA, West R, Scott DJ. Reproducibility of ultrasound measurement of the abdominal aorta. Br J Surg. 2011 Nov;98(11):1517-25. doi: 10.1002/bjs.7628. Epub 2011 Aug 22. — View Citation

Bley TA, Chase PJ, Reeder SB, Francois CJ, Shinki K, Tefera G, Ranallo FN, Grist TM, Pozniak M. Endovascular abdominal aortic aneurysm repair: nonenhanced volumetric CT for follow-up. Radiology. 2009 Oct;253(1):253-62. doi: 10.1148/radiol.2531082093. Epub 2009 Jul 31. — View Citation

Caradu C, Spampinato B, Vrancianu AM, Berard X, Ducasse E. Fully automatic volume segmentation of infrarenal abdominal aortic aneurysm computed tomography images with deep learning approaches versus physician controlled manual segmentation. J Vasc Surg. 2021 Jul;74(1):246-256.e6. doi: 10.1016/j.jvs.2020.11.036. Epub 2020 Dec 9. — View Citation

Chaikof EL, Dalman RL, Eskandari MK, Jackson BM, Lee WA, Mansour MA, Mastracci TM, Mell M, Murad MH, Nguyen LL, Oderich GS, Patel MS, Schermerhorn ML, Starnes BW. The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysm. J Vasc Surg. 2018 Jan;67(1):2-77.e2. doi: 10.1016/j.jvs.2017.10.044. — View Citation

Claridge R, Arnold S, Morrison N, van Rij AM. Measuring abdominal aortic diameters in routine abdominal computed tomography scans and implications for abdominal aortic aneurysm screening. J Vasc Surg. 2017 Jun;65(6):1637-1642. doi: 10.1016/j.jvs.2016.11.044. Epub 2017 Feb 16. — View Citation

de Bruijne M, van Ginneken B, Viergever MA, Niessen WJ. Interactive segmentation of abdominal aortic aneurysms in CTA images. Med Image Anal. 2004 Jun;8(2):127-38. doi: 10.1016/j.media.2004.01.001. — View Citation

Ellis M, Powell JT, Greenhalgh RM. Limitations of ultrasonography in surveillance of small abdominal aortic aneurysms. Br J Surg. 1991 May;78(5):614-6. doi: 10.1002/bjs.1800780529. — View Citation

Georgakarakos E, Ioannou CV, Kamarianakis Y, Papaharilaou Y, Kostas T, Manousaki E, Katsamouris AN. The role of geometric parameters in the prediction of abdominal aortic aneurysm wall stress. Eur J Vasc Endovasc Surg. 2010 Jan;39(1):42-8. doi: 10.1016/j.ejvs.2009.09.026. Epub 2009 Nov 10. — View Citation

Ghouri M, Krajcer Z. Endoluminal abdominal aortic aneurysm repair: the latest advances in prevention of distal endograft migration and type 1 endoleak. Tex Heart Inst J. 2010;37(1):19-24. — View Citation

Houard X, Ollivier V, Louedec L, Michel JB, Back M. Differential inflammatory activity across human abdominal aortic aneurysms reveals neutrophil-derived leukotriene B4 as a major chemotactic factor released from the intraluminal thrombus. FASEB J. 2009 May;23(5):1376-83. doi: 10.1096/fj.08-116202. Epub 2009 Jan 9. — View Citation

Houard X, Rouzet F, Touat Z, Philippe M, Dominguez M, Fontaine V, Sarda-Mantel L, Meulemans A, Le Guludec D, Meilhac O, Michel JB. Topology of the fibrinolytic system within the mural thrombus of human abdominal aortic aneurysms. J Pathol. 2007 May;212(1):20-8. doi: 10.1002/path.2148. — View Citation

Jongkind V, Yeung KK, Akkersdijk GJ, Heidsieck D, Reitsma JB, Tangelder GJ, Wisselink W. Juxtarenal aortic aneurysm repair. J Vasc Surg. 2010 Sep;52(3):760-7. doi: 10.1016/j.jvs.2010.01.049. Epub 2010 Apr 10. — View Citation

Kauffmann C, Tang A, Therasse E, Giroux MF, Elkouri S, Melanson P, Melanson B, Oliva VL, Soulez G. Measurements and detection of abdominal aortic aneurysm growth: Accuracy and reproducibility of a segmentation software. Eur J Radiol. 2012 Aug;81(8):1688-94. doi: 10.1016/j.ejrad.2011.04.044. Epub 2011 May 20. — View Citation

Kritpracha B, Beebe HG, Comerota AJ. Aortic diameter is an insensitive measurement of early aneurysm expansion after endografting. J Endovasc Ther. 2004 Apr;11(2):184-90. doi: 10.1583/03-976.1. — View Citation

Lederle FA, Johnson GR, Wilson SE, Chute EP, Littooy FN, Bandyk D, Krupski WC, Barone GW, Acher CW, Ballard DJ. Prevalence and associations of abdominal aortic aneurysm detected through screening. Aneurysm Detection and Management (ADAM) Veterans Affairs Cooperative Study Group. Ann Intern Med. 1997 Mar 15;126(6):441-9. doi: 10.7326/0003-4819-126-6-199703150-00004. — View Citation

Lindholt JS, Vammen S, Juul S, Henneberg EW, Fasting H. The validity of ultrasonographic scanning as screening method for abdominal aortic aneurysm. Eur J Vasc Endovasc Surg. 1999 Jun;17(6):472-5. doi: 10.1053/ejvs.1999.0835. — View Citation

Long A, Rouet L, Lindholt JS, Allaire E. Measuring the maximum diameter of native abdominal aortic aneurysms: review and critical analysis. Eur J Vasc Endovasc Surg. 2012 May;43(5):515-24. doi: 10.1016/j.ejvs.2012.01.018. Epub 2012 Feb 14. — View Citation

Lopez-Linares K, Aranjuelo N, Kabongo L, Maclair G, Lete N, Ceresa M, Garcia-Familiar A, Macia I, Gonzalez Ballester MA. Fully automatic detection and segmentation of abdominal aortic thrombus in post-operative CTA images using Deep Convolutional Neural Networks. Med Image Anal. 2018 May;46:202-214. doi: 10.1016/j.media.2018.03.010. Epub 2018 Mar 27. — View Citation

Mell MW, Hlatky MA, Shreibati JB, Dalman RL, Baker LC. Late diagnosis of abdominal aortic aneurysms substantiates underutilization of abdominal aortic aneurysm screening for Medicare beneficiaries. J Vasc Surg. 2013 Jun;57(6):1519-23, 1523.e1. doi: 10.1016/j.jvs.2012.12.034. Epub 2013 Feb 12. — View Citation

Moll FL, Powell JT, Fraedrich G, Verzini F, Haulon S, Waltham M, van Herwaarden JA, Holt PJ, van Keulen JW, Rantner B, Schlosser FJ, Setacci F, Ricco JB; European Society for Vascular Surgery. Management of abdominal aortic aneurysms clinical practice guidelines of the European society for vascular surgery. Eur J Vasc Endovasc Surg. 2011 Jan;41 Suppl 1:S1-S58. doi: 10.1016/j.ejvs.2010.09.011. No abstract available. — View Citation

Nambi P, Sengupta R, Krajcer Z, Muthupillai R, Strickman N, Cheong BY. Non-contrast computed tomography is comparable to contrast-enhanced computed tomography for aortic volume analysis after endovascular abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg. 2011 Apr;41(4):460-6. doi: 10.1016/j.ejvs.2010.11.027. Epub 2010 Dec 31. — View Citation

Nicholls SC, Gardner JB, Meissner MH, Johansen HK. Rupture in small abdominal aortic aneurysms. J Vasc Surg. 1998 Nov;28(5):884-8. doi: 10.1016/s0741-5214(98)70065-5. — View Citation

Norman PE, Jamrozik K, Lawrence-Brown MM, Le MT, Spencer CA, Tuohy RJ, Parsons RW, Dickinson JA. Population based randomised controlled trial on impact of screening on mortality from abdominal aortic aneurysm. BMJ. 2004 Nov 27;329(7477):1259. doi: 10.1136/bmj.38272.478438.55. Epub 2004 Nov 15. Erratum In: BMJ. 2005 Mar 12;330(7491):596. — View Citation

Parr A, Jayaratne C, Buttner P, Golledge J. Comparison of volume and diameter measurement in assessing small abdominal aortic aneurysm expansion examined using computed tomographic angiography. Eur J Radiol. 2011 Jul;79(1):42-7. doi: 10.1016/j.ejrad.2009.12.018. Epub 2010 Jan 12. — View Citation

Parr A, McCann M, Bradshaw B, Shahzad A, Buttner P, Golledge J. Thrombus volume is associated with cardiovascular events and aneurysm growth in patients who have abdominal aortic aneurysms. J Vasc Surg. 2011 Jan;53(1):28-35. doi: 10.1016/j.jvs.2010.08.013. — View Citation

Powell JT, Brown LC, Forbes JF, Fowkes FG, Greenhalgh RM, Ruckley CV, Thompson SG. Final 12-year follow-up of surgery versus surveillance in the UK Small Aneurysm Trial. Br J Surg. 2007 Jun;94(6):702-8. doi: 10.1002/bjs.5778. — View Citation

Powell JT, Sweeting MJ, Brown LC, Gotensparre SM, Fowkes FG, Thompson SG. Systematic review and meta-analysis of growth rates of small abdominal aortic aneurysms. Br J Surg. 2011 May;98(5):609-18. doi: 10.1002/bjs.7465. Epub 2011 Mar 17. — View Citation

Prinssen M, Verhoeven EL, Verhagen HJ, Blankensteijn JD. Decision-making in follow-up after endovascular aneurysm repair based on diameter and volume measurements: a blinded comparison. Eur J Vasc Endovasc Surg. 2003 Aug;26(2):184-7. doi: 10.1053/ejvs.2002.1892. — View Citation

Riambau V, Bockler D, Brunkwall J, Cao P, Chiesa R, Coppi G, Czerny M, Fraedrich G, Haulon S, Jacobs MJ, Lachat ML, Moll FL, Setacci C, Taylor PR, Thompson M, Trimarchi S, Verhagen HJ, Verhoeven EL, Esvs Guidelines Committee, Kolh P, de Borst GJ, Chakfe N, Debus ES, Hinchliffe RJ, Kakkos S, Koncar I, Lindholt JS, Vega de Ceniga M, Vermassen F, Verzini F, Document Reviewers, Kolh P, Black JH 3rd, Busund R, Bjorck M, Dake M, Dick F, Eggebrecht H, Evangelista A, Grabenwoger M, Milner R, Naylor AR, Ricco JB, Rousseau H, Schmidli J. Editor's Choice - Management of Descending Thoracic Aorta Diseases: Clinical Practice Guidelines of the European Society for Vascular Surgery (ESVS). Eur J Vasc Endovasc Surg. 2017 Jan;53(1):4-52. doi: 10.1016/j.ejvs.2016.06.005. No abstract available. — View Citation

Satta J, Laara E, Juvonen T. Intraluminal thrombus predicts rupture of an abdominal aortic aneurysm. J Vasc Surg. 1996 Apr;23(4):737-9. doi: 10.1016/s0741-5214(96)80062-0. No abstract available. — View Citation

Scott RA, Wilson NM, Ashton HA, Kay DN. Influence of screening on the incidence of ruptured abdominal aortic aneurysm: 5-year results of a randomized controlled study. Br J Surg. 1995 Aug;82(8):1066-70. doi: 10.1002/bjs.1800820821. — View Citation

Scott SW, Batchelder AJ, Kirkbride D, Naylor AR, Thompson JP. Late Survival in Nonoperated Patients with Infrarenal Abdominal Aortic Aneurysm. Eur J Vasc Endovasc Surg. 2016 Oct;52(4):444-449. doi: 10.1016/j.ejvs.2016.05.008. Epub 2016 Jun 30. — View Citation

Singh K, Jacobsen BK, Solberg S, Bonaa KH, Kumar S, Bajic R, Arnesen E. Intra- and interobserver variability in the measurements of abdominal aortic and common iliac artery diameter with computed tomography. The Tromso study. Eur J Vasc Endovasc Surg. 2003 May;25(5):399-407. doi: 10.1053/ejvs.2002.1856. — View Citation

Speelman L, Schurink GW, Bosboom EM, Buth J, Breeuwer M, van de Vosse FN, Jacobs MH. The mechanical role of thrombus on the growth rate of an abdominal aortic aneurysm. J Vasc Surg. 2010 Jan;51(1):19-26. doi: 10.1016/j.jvs.2009.08.075. Epub 2009 Nov 27. — View Citation

Stenbaek J, Kalin B, Swedenborg J. Growth of thrombus may be a better predictor of rupture than diameter in patients with abdominal aortic aneurysms. Eur J Vasc Endovasc Surg. 2000 Nov;20(5):466-9. doi: 10.1053/ejvs.2000.1217. — View Citation

Szilagyi DE, Elliott JP, Smith RF. Clinical fate of the patient with asymptomatic abdominal aortic aneurysm and unfit for surgical treatment. Arch Surg. 1972 Apr;104(4):600-6. doi: 10.1001/archsurg.1972.04180040214036. No abstract available. — View Citation

Taha AA, Hanbury A. Metrics for evaluating 3D medical image segmentation: analysis, selection, and tool. BMC Med Imaging. 2015 Aug 12;15:29. doi: 10.1186/s12880-015-0068-x. — View Citation

Tonnessen BH, Sternbergh WC 3rd, Money SR. Mid- and long-term device migration after endovascular abdominal aortic aneurysm repair: a comparison of AneuRx and Zenith endografts. J Vasc Surg. 2005 Sep;42(3):392-400; discussion 400-1. doi: 10.1016/j.jvs.2005.05.040. — View Citation

van Keulen JW, van Prehn J, Prokop M, Moll FL, van Herwaarden JA. Potential value of aneurysm sac volume measurements in addition to diameter measurements after endovascular aneurysm repair. J Endovasc Ther. 2009 Aug;16(4):506-13. doi: 10.1583/09-2690.1. — View Citation

Vorp DA, Vande Geest JP. Biomechanical determinants of abdominal aortic aneurysm rupture. Arterioscler Thromb Vasc Biol. 2005 Aug;25(8):1558-66. doi: 10.1161/01.ATV.0000174129.77391.55. — View Citation

Walker TG, Kalva SP, Yeddula K, Wicky S, Kundu S, Drescher P, d'Othee BJ, Rose SC, Cardella JF; Society of Interventional Radiology Standards of Practice Committee; Interventional Radiological Society of Europe; Canadian Interventional Radiology Association. Clinical practice guidelines for endovascular abdominal aortic aneurysm repair: written by the Standards of Practice Committee for the Society of Interventional Radiology and endorsed by the Cardiovascular and Interventional Radiological Society of Europe and the Canadian Interventional Radiology Association. J Vasc Interv Radiol. 2010 Nov;21(11):1632-55. doi: 10.1016/j.jvir.2010.07.008. Epub 2010 Sep 29. No abstract available. — View Citation

Wanhainen A, Verzini F, Van Herzeele I, Allaire E, Bown M, Cohnert T, Dick F, van Herwaarden J, Karkos C, Koelemay M, Kolbel T, Loftus I, Mani K, Melissano G, Powell J, Szeberin Z, Esvs Guidelines Committee, de Borst GJ, Chakfe N, Debus S, Hinchliffe R, Kakkos S, Koncar I, Kolh P, Lindholt JS, de Vega M, Vermassen F, Document Reviewers, Bjorck M, Cheng S, Dalman R, Davidovic L, Donas K, Earnshaw J, Eckstein HH, Golledge J, Haulon S, Mastracci T, Naylor R, Ricco JB, Verhagen H. Editor's Choice - European Society for Vascular Surgery (ESVS) 2019 Clinical Practice Guidelines on the Management of Abdominal Aorto-iliac Artery Aneurysms. Eur J Vasc Endovasc Surg. 2019 Jan;57(1):8-93. doi: 10.1016/j.ejvs.2018.09.020. Epub 2018 Dec 5. No abstract available. Erratum In: Eur J Vasc Endovasc Surg. 2020 Mar;59(3):494. — View Citation

Wever JJ, Blankensteijn JD, Th M Mali WP, Eikelboom BC. Maximal aneurysm diameter follow-up is inadequate after endovascular abdominal aortic aneurysm repair. Eur J Vasc Endovasc Surg. 2000 Aug;20(2):177-82. doi: 10.1053/ejvs.1999.1051. — View Citation

Wyss TR, Brown LC, Powell JT, Greenhalgh RM. Rate and predictability of graft rupture after endovascular and open abdominal aortic aneurysm repair: data from the EVAR Trials. Ann Surg. 2010 Nov;252(5):805-12. doi: 10.1097/SLA.0b013e3181fcb44a. — View Citation

* Note: There are 46 references in allClick here to view all references

Outcome

Type Measure Description Time frame Safety issue
Primary orthogonal maximum diameter of the aorta (mm) 3 months
Primary Thoraco-Aortic lengths of the aorta (in mm) Proximal neck length
Infrarenal Aortic length
Left common Iliac artery length
Right common Iliac artery length
3 months
Primary Infrarenal volume of the aorta (in cm3) Volume circulating
Intraluminal thrombus volume
Total volume
3 months
Primary Aorta and iliacs diameters at several places (in mm) Aortic diameter above the uppermost renal artery
Upper proximal Neck Diameter
Neck Diameter 5mm under the lower renal
Neck Diameter 10mm under the lower renal
Neck Diameter 15mm under the lower renal
Neck diameter 20mm under the lower renal
Lower proximal Neck Diameter
Proximal right common Iliac artery Diameter
Middle right common iliac artery Diameter
Distal right common Iliac artery Diameter
Distal right external iliac artery Diameter
Proximal left common Iliac artery Diameter
Middle left common iliac artery Diameter
Distal left common iliac artery Diameter
Distal left external Iliac Diameter
Aortic bifurcation diameter
3 months
Primary Suprarenal angulation (in hour and degree) Angle between the suprarenal aorta and the neck 3 months
Primary Infrarenal angulation (in hour and degree) Angle between the neck and aneurysm 3 months
Secondary Healthcare professional trust questionnaire Do the professional trust or not the result returned by the software ? Yes or No reported in the CRF 2 days
Secondary Scan analyse time from segmentation to measurements Time for analysis by the surgeon from segmentation to measurements Time for analysis by the automatique software from segmentation to measurement 3 months
Secondary Unanticipated risks Risks that haven't been anticipated by Nurea, related to the use of the software 3 days
Secondary Number of male and female the patient sex is collected in the CRF 1 day
Secondary Number of patient per age the patient age is collected in the CRF 1 day
See also
  Status Clinical Trial Phase
Recruiting NCT04149600 - Identification of Genetic Causes of Calcific Aortic Valve Disease
Enrolling by invitation NCT04035356 - HAART Annuloplasty Device Valve Repair Registry
Recruiting NCT02729064 - Intraoperative Nasal Insulin Effect on Plasma and CSF Insulin Concentration and Blood Glucose Phase 1
Completed NCT02467062 - Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease. N/A
Completed NCT02283307 - Dual Energy CT Urography With Reduced Iodinated Contrast N/A
Completed NCT01678261 - X-chromosome Inactivation, Epigenetics and the Transcriptome N/A
Terminated NCT01055275 - Cook Iliac Branch Graft Post-market Registry N/A
Completed NCT00615888 - Fast Track Management in Elective Open Infrarenal Aortic Aneurysm Repair N/A
Completed NCT03510793 - Microcirculation and Anesthesia in Vascular Surgery
Completed NCT03207568 - RE-GENERATION: The Safety and Performance of the Relay Pro and Relay NBS Pro Stent-graft Devices in the European Union (EU) N/A
Recruiting NCT05073991 - Incidence of Mortality and Complications After Lung Surgery, Open Thoracic Aortic Repair, TEVAR, EVAR.
Not yet recruiting NCT01918969 - Reference Values of Circulating Endothelial Progenitor Cells N/A
Not yet recruiting NCT01918982 - Circulating Endothelial Progenitor Cells and Aortic Aneurysm N/A
Completed NCT02000544 - Clinical Evaluation of a Modular Extracorporeal Circulation Circuit N/A
Completed NCT01256372 - An Trial of Two Dosing Regimens of AP214 for the Prevention of Kidney Injury in Patients Undergoing Cardiac Surgery Phase 2
Recruiting NCT00661518 - PET/CT Imaging of Aneurysm Wall Inflammation N/A
Completed NCT00094575 - Standard Open Surgery Versus Endovascular Repair of Abdominal Aortic Aneurysm (AAA) Phase 4
Recruiting NCT04471909 - NEXUS Aortic Arch Clinical Study to Evaluate Safety and Effectiveness N/A
Recruiting NCT05603520 - Phenotyping Heterogeneity and Regionality of the Aorta
Completed NCT03727542 - Influence of Short AV Delay Permanent Pacing on Matrix Metalloproteinase Levels N/A