Clinical Trials Logo

Clinical Trial Details — Status: Completed

Administrative data

NCT number NCT05150873
Other study ID # 3499
Secondary ID
Status Completed
Phase
First received
Last updated
Start date January 1, 2022
Est. completion date December 1, 2022

Study information

Verified date February 2024
Source Azienda Ospedaliero-Universitaria di Modena
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

In clinical practice a lot of EVAR cases are performed IFU for adverse neck anatomy(6) with acceptable short- and mid-term outcomes, but the long-term durability is currently an issue (7). Neck length shorter than 15 mm and angulation are two of. neck charteristics. that contribute more to define an "hostile neck" (8). The issue linked to the anatomical not feasibility of standard EVAR in patients not eligible for OR can be solved with custom made devices (CMD), but they were limited by high production costs and long time for creations (10-12 weeks)1. Nowadays no one off-the-shelf device aimed to overcome neck hostility in AAA is available on the market. The present study aims at evaluating the anatomical applicability of an off-the-shelf scalloped stent-graft to treat infrarenal AAA with a short and/or angulated neck.


Description:

Endovascular aneurysm repair (EVAR) is currently accepted as the preferred choice to treat abdominal aortic aneurysms (AAA) with feasible anatomy. Although approximately 40-60% of AAA patients are not considered anatomically feasible for EVAR, mainly in reason of a "hostile neck anatomy". In ''real-world'' clinical practice, up to 44% of EVAR cases are performed outside Instruction For Use (IFU) for adverse neck anatomy. The off-label use of standard EVAR is currently used for patients who are not eligible for OR, with acceptable short- and mid-term outcomes, Endovascular aneurysm repair (EVAR) is currently accepted as the preferred choice to treat the abdominal aortic aneurysms (AAA) with feasible anatomy. Although approximately 40-60% of AAA patients are not considered anatomically feasible for EVAR, mainly in reason of a "hostile neck anatomy"3-5. In ''real-world'' clinical practice, up to 44% of EVAR cases are performed outside Instruction For Use (IFU) for adverse neck anatomy. The off-label use of standard EVAR is currently used for patients who are not eligible for OR, with acceptable short- and mid-term outcomes, but the long-term durability of EVAR depends on the maintenance of the seal between the endograft and the aortic neck as well as the iliac arteries. Some aortic neck characteristics contribute to the definition of ''hostile neck,'' particularly length shorter than 15 mm and angulation among others. From a recent Consensus Conference, the influence of each characteristic on early or late EVAR failure is not clear, but hostile neck morphology is generally associated with higher rates of aneurysm-related adverse events and mortality. A recent independent Expert Panel, applying the Delphi methodology Indeed, agreed to define 10 mm as the threshold value below which standard EVAR should not be considered feasible. Moreover, the same experts agreed on the fact that an angulation above 60° is considered a hostile criterion for EVAR procedure. Finally should be considered that some "hostility" factors can be present at the same time and create the ideal condition for EVAR failure. The issue linked to the anatomical not the feasibility of standard EVAR in patients not eligible for OR can be solved with custom made devices (CMD), but they were limited by high production costs and long time for creations (10-12 weeks)1. Nowadays no one off-the-shelf device aimed to overcome neck hostility in AAA is available on the market. The present study aims at evaluating the anatomical applicability of an off-the-shelf scalloped stent graft to treat infrarenal AAA with a short and/or angulated neck. From an informal review of some CTA of patients treated with EVAR or OR in mentioned unit, the authors found that more the 20% presented a distance between the two renal arteries more than 5mm. The idea of an "off-the-shelf" graft with a single scallop theoretically had to permit to gain some length along the aortic neck. Furthermore also in the case of angulation, a single scallop theoretically reduced the risk of bird beck and gutter. The aim of the study is to evaluate if a single scalloped "off-the-shelf" stent graft could be appliable and feasible in an adequate number of patients.


Recruitment information / eligibility

Status Completed
Enrollment 1000
Est. completion date December 1, 2022
Est. primary completion date June 1, 2022
Accepts healthy volunteers
Gender All
Age group 18 Years and older
Eligibility Inclusion Criteria: - Patients Electively treated with EVAR or AAA at the coordinator center - Age >18 - Both sex - Preoperative 2.5mm CTA available - Written informed consent. Exclusion Criteria: - All. patients not fulfilling the inclusion criteria

Study Design


Related Conditions & MeSH terms


Intervention

Other:
CTA evaluation
Any pre-operattive CTA of the patients of the cohort will be carefully evaluated to determine the theoric anatomical feasibility of an off the shelf Endograft, particularly in patients with an angulated and short aortic neck

Locations

Country Name City State
Italy AOU di Modena, OCB Baggiovara Modena

Sponsors (1)

Lead Sponsor Collaborator
Azienda Ospedaliero-Universitaria di Modena

Country where clinical trial is conducted

Italy, 

References & Publications (10)

AbuRahma AF, DerDerian T, AbuRahma ZT, Hass SM, Yacoub M, Dean LS, Abu-Halimah S, Mousa AY. Comparative study of clinical outcome of endovascular aortic aneurysms repair in large diameter aortic necks (>31 mm) versus smaller necks. J Vasc Surg. 2018 Nov;68(5):1345-1353.e1. doi: 10.1016/j.jvs.2018.02.037. Epub 2018 May 22. — View Citation

Caradu C, Berard X, Midy D, Ducasse E. Influence of Anatomic Angulations in Chimney and Fenestrated Endovascular Aneurysm Repair. Ann Vasc Surg. 2017 Aug;43:104-114. doi: 10.1016/j.avsg.2017.01.002. Epub 2017 Feb 28. — View Citation

Chaikof EL, Dalman RL, Eskandari MK, Jackson BM, Lee WA, Mansour MA, Mastracci TM, Mell M, Murad MH, Nguyen LL, Oderich GS, Patel MS, Schermerhorn ML, Starnes BW. The Society for Vascular Surgery practice guidelines on the care of patients with an abdomin — View Citation

Chaikof EL, Fillinger MF, Matsumura JS, Rutherford RB, White GH, Blankensteijn JD, Bernhard VM, Harris PL, Kent KC, May J, Veith FJ, Zarins CK. Identifying and grading factors that modify the outcome of endovascular aortic aneurysm repair. J Vasc Surg. 2002 May;35(5):1061-6. doi: 10.1067/mva.2002.123991. No abstract available. — View Citation

Gallitto E, Faggioli G, Spath P, Pini R, Mascoli C, Ancetti S, Stella A, Abualhin M, Gargiulo M. The risk of aneurysm rupture and target visceral vessel occlusion during the lead period of custom-made fenestrated/branched endograft. J Vasc Surg. 2020 Jul;72(1):16-24. doi: 10.1016/j.jvs.2019.08.273. Epub 2020 Feb 13. — View Citation

Gimenez-Gaibar A, Gonzalez-Canas E, Solanich-Valldaura T, Herranz-Pinilla C, Rioja-Artal S, Ferraz-Huguet E. Could Preoperative Neck Anatomy Influence Follow-up of EVAR? Ann Vasc Surg. 2017 Aug;43:127-133. doi: 10.1016/j.avsg.2016.12.011. Epub 2017 Apr 6. — View Citation

Marone EM, Freyrie A, Ruotolo C, Michelagnoli S, Antonello M, Speziale F, Veroux P, Gargiulo M, Gaggiano A. Expert Opinion on Hostile Neck Definition in Endovascular Treatment of Abdominal Aortic Aneurysms (a Delphi Consensus). Ann Vasc Surg. 2020 Jan;62:173-182. doi: 10.1016/j.avsg.2019.05.049. Epub 2019 Aug 6. — View Citation

Muhs BE, Jordan W, Ouriel K, Rajaee S, de Vries JP. Matched cohort comparison of endovascular abdominal aortic aneurysm repair with and without EndoAnchors. J Vasc Surg. 2018 Jun;67(6):1699-1707. doi: 10.1016/j.jvs.2017.10.059. Epub 2017 Dec 18. — View Citation

Speziale F, Sirignano P, Setacci F, Menna D, Capoccia L, Mansour W, Galzerano G, Setacci C. Immediate and two-year outcomes after EVAR in "on-label" and "off-label" neck anatomies using different commercially available devices. analysis of the experience of two Italian vascular centers. Ann Vasc Surg. 2014 Nov;28(8):1892-900. doi: 10.1016/j.avsg.2014.06.057. Epub 2014 Jul 7. — View Citation

Wanhainen A, Verzini F, Van Herzeele I, Allaire E, Bown M, Cohnert T, Dick F, van Herwaarden J, Karkos C, Koelemay M, Kolbel T, Loftus I, Mani K, Melissano G, Powell J, Szeberin Z, Esvs Guidelines Committee, de Borst GJ, Chakfe N, Debus S, Hinchliffe R, Kakkos S, Koncar I, Kolh P, Lindholt JS, de Vega M, Vermassen F, Document Reviewers, Bjorck M, Cheng S, Dalman R, Davidovic L, Donas K, Earnshaw J, Eckstein HH, Golledge J, Haulon S, Mastracci T, Naylor R, Ricco JB, Verhagen H. Editor's Choice - European Society for Vascular Surgery (ESVS) 2019 Clinical Practice Guidelines on the Management of Abdominal Aorto-iliac Artery Aneurysms. Eur J Vasc Endovasc Surg. 2019 Jan;57(1):8-93. doi: 10.1016/j.ejvs.2018.09.020. Epub 2018 Dec 5. No abstract available. Erratum In: Eur J Vasc Endovasc Surg. 2020 Mar;59(3):494. — View Citation

Outcome

Type Measure Description Time frame Safety issue
Primary Anatomica feasibility and applicability of an "off-the-shelf" scallopped stent-graft measured mesured fitting three device model with data recorded from CTA of patients with AAA treted in our unit observational study on the anatomical applicability in the coordinator center of an off-the-shelf scalloped device to treat infrarenal AAA with short and/or angulated neck. 3 different endograft designs were constructed. The preoperative measurements were made according to a previously described methodology. The models were matched with each preoperative CTA measure in order to evaluate if they fit or not in the index patients. 6-months
See also
  Status Clinical Trial Phase
Recruiting NCT04149600 - Identification of Genetic Causes of Calcific Aortic Valve Disease
Enrolling by invitation NCT04035356 - HAART Annuloplasty Device Valve Repair Registry
Recruiting NCT02729064 - Intraoperative Nasal Insulin Effect on Plasma and CSF Insulin Concentration and Blood Glucose Phase 1
Completed NCT02467062 - Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease. N/A
Completed NCT02283307 - Dual Energy CT Urography With Reduced Iodinated Contrast N/A
Completed NCT01678261 - X-chromosome Inactivation, Epigenetics and the Transcriptome N/A
Terminated NCT01055275 - Cook Iliac Branch Graft Post-market Registry N/A
Completed NCT00615888 - Fast Track Management in Elective Open Infrarenal Aortic Aneurysm Repair N/A
Completed NCT03510793 - Microcirculation and Anesthesia in Vascular Surgery
Completed NCT03207568 - RE-GENERATION: The Safety and Performance of the Relay Pro and Relay NBS Pro Stent-graft Devices in the European Union (EU) N/A
Recruiting NCT05073991 - Incidence of Mortality and Complications After Lung Surgery, Open Thoracic Aortic Repair, TEVAR, EVAR.
Completed NCT02000544 - Clinical Evaluation of a Modular Extracorporeal Circulation Circuit N/A
Not yet recruiting NCT01918982 - Circulating Endothelial Progenitor Cells and Aortic Aneurysm N/A
Not yet recruiting NCT01918969 - Reference Values of Circulating Endothelial Progenitor Cells N/A
Completed NCT01256372 - An Trial of Two Dosing Regimens of AP214 for the Prevention of Kidney Injury in Patients Undergoing Cardiac Surgery Phase 2
Recruiting NCT00661518 - PET/CT Imaging of Aneurysm Wall Inflammation N/A
Completed NCT00094575 - Standard Open Surgery Versus Endovascular Repair of Abdominal Aortic Aneurysm (AAA) Phase 4
Recruiting NCT04471909 - NEXUS Aortic Arch Clinical Study to Evaluate Safety and Effectiveness N/A
Recruiting NCT05603520 - Phenotyping Heterogeneity and Regionality of the Aorta
Completed NCT03727542 - Influence of Short AV Delay Permanent Pacing on Matrix Metalloproteinase Levels N/A