Clinical Trials Logo

Clinical Trial Summary

This pilot study aims to quantitatively characterize the stresses and forces on an implanted endograft during the cardiac cycle in patients scheduled for standard endograft follow-up. The developed techniques will be applied in future studies for characterizing and comparing the currently commercially available endografts so as to gain insight into the mechanisms underlying potential endograft failure. In addition, to assist in developing endografts with long-term durability and functioning characteristics for the benefit of the patient


Clinical Trial Description

Endovascular Aortic replacement (EVAR) for the treatment of aortic aneurysms in patients at risk of aneurysm rupture is an established endovascular technique (ref: Blankensteijn, NEJM, 2005). However, the development of the endograft design is ongoing in order to prevent late endograft failure (e.g. graft breakage, graft displacement). The stresses and forces applied to the endograft by the high physiological forces and stresses in the aorta have an effect on the durability and functioning of the endograft. The stresses and forces that occur during movement may be reflected by movement of the endograft itself during the cardiac cycle. Standard patient follow-up involves transverse CT imaging to detect endograft leakage. However, transverse imaging does not provide information on endograft displacement but does provide information on shrinkage of the aneurysm after endograft placement. Therefore, additional information on the longitudinal displacement of the endograft during the cardiac cycle may assist in determining the optimal characteristics of a durable endograft and therefore benefit the patient in the long-term. Evaluation of the stresses and forces by calculating longitudinal displacement of the endograft appears possible by applying a cardiac CT technique, namely, dynamic CTA (computed tomography angiography), on an endovascular device. To our knowledge, this new approach will yield new in vivo data on endograft behavior.

This pilot study aims to quantitatively characterize the stresses and forces on an implanted endograft during the cardiac cycle in patients scheduled for standard endograft follow-up. In addition, in order to have the possibility to compare the movement of the aorta pre- and post-endograft placement, the aorta of patients planned for an endograft implantation procedure and who are thus already planned to undergo a clinical CT will also instead be scanned using ECG gated dynamic CTprotocol.

The developed techniques will be applied in future studies for characterizing and comparing the currently commercially available endografts so as to gain insight into the mechanisms underlying potential endograft failure, and in addition, to assist in developing endografts with long-term durability and functioning characteristics for the benefit of the patient. ;


Study Design

Observational Model: Cohort, Time Perspective: Prospective


Related Conditions & MeSH terms


NCT number NCT00680004
Study type Observational
Source Radboud University
Contact Leo Schultze Kool, MD
Phone +31243614546
Email l.schultzekool@rad.umcn.nl
Status Recruiting
Phase N/A
Start date January 2007
Completion date December 2009

See also
  Status Clinical Trial Phase
Recruiting NCT04149600 - Identification of Genetic Causes of Calcific Aortic Valve Disease
Enrolling by invitation NCT04035356 - HAART Annuloplasty Device Valve Repair Registry
Recruiting NCT02729064 - Intraoperative Nasal Insulin Effect on Plasma and CSF Insulin Concentration and Blood Glucose Phase 1
Completed NCT02467062 - Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease. N/A
Completed NCT02283307 - Dual Energy CT Urography With Reduced Iodinated Contrast N/A
Completed NCT01678261 - X-chromosome Inactivation, Epigenetics and the Transcriptome N/A
Terminated NCT01055275 - Cook Iliac Branch Graft Post-market Registry N/A
Completed NCT00615888 - Fast Track Management in Elective Open Infrarenal Aortic Aneurysm Repair N/A
Completed NCT03510793 - Microcirculation and Anesthesia in Vascular Surgery
Completed NCT03207568 - RE-GENERATION: The Safety and Performance of the Relay Pro and Relay NBS Pro Stent-graft Devices in the European Union (EU) N/A
Recruiting NCT05073991 - Incidence of Mortality and Complications After Lung Surgery, Open Thoracic Aortic Repair, TEVAR, EVAR.
Not yet recruiting NCT01918969 - Reference Values of Circulating Endothelial Progenitor Cells N/A
Not yet recruiting NCT01918982 - Circulating Endothelial Progenitor Cells and Aortic Aneurysm N/A
Completed NCT02000544 - Clinical Evaluation of a Modular Extracorporeal Circulation Circuit N/A
Completed NCT01256372 - An Trial of Two Dosing Regimens of AP214 for the Prevention of Kidney Injury in Patients Undergoing Cardiac Surgery Phase 2
Recruiting NCT00661518 - PET/CT Imaging of Aneurysm Wall Inflammation N/A
Completed NCT00094575 - Standard Open Surgery Versus Endovascular Repair of Abdominal Aortic Aneurysm (AAA) Phase 4
Recruiting NCT04471909 - NEXUS Aortic Arch Clinical Study to Evaluate Safety and Effectiveness N/A
Recruiting NCT05603520 - Phenotyping Heterogeneity and Regionality of the Aorta
Completed NCT03727542 - Influence of Short AV Delay Permanent Pacing on Matrix Metalloproteinase Levels N/A