Clinical Trials Logo

Aortic Aneurysm clinical trials

View clinical trials related to Aortic Aneurysm.

Filter by:
  • Withdrawn  
  • Page 1 ·  Next »

NCT ID: NCT05964348 Withdrawn - Aneurysm Aortic Clinical Trials

REGISTRY for the Use of a Software for Automatic Detection of the Evolution of Aneurysmal Volume and Graft Migration After EVAR (EndoVascular Aneurysm Repair)

AI-EVAR-FOLLOW
Start date: April 5, 2023
Phase:
Study type: Observational

The objective of this registry is to find and validate a correlation between morphological indicators such as volume sac evolution, graft migration or length between anatomical landmarks with aneurysm rupture risk or complications such as endoleaks requiring re-intervention… Secondary objectives are the validation of the reproducibility and accuracy of a dedicated fully automated software enabling Abdominal Aortic Aneurysm (AAA) segmentation to measure AAA diameter, volume evolution and growth over time, proximal and distal sealing zones analyze as well as device migration and integrity after EVAR on computed tomography angiography (CTA). This validation is in comparison with semi-automated analyse controlled by physician.

NCT ID: NCT04615559 Withdrawn - Clinical trials for Abdominal Aortic Aneurysm

Contrast Enhanced Ultrasound Endoleak Identification and Classification

Start date: December 2020
Phase: N/A
Study type: Interventional

Surgery for abdominal aortic pathology usually occurs in the setting of advanced cardiovascular disease. The repair can be relatively simple or complex with multiple steps including open repair, placing a stent with a catheter, and placing a complicated stent that allows for crossing vessels without occluding them. All these repairs require imaging follow up. The most commonly accepted tool for follow up is Computed Tomography (CT) scan which involves ionizing radiation and potentially nephrotoxic iodinated contrast. Recommendations for the time interval for follow up, as well the radiology imaging technique vary. Routine ultrasound with Doppler, CT, and MRI has all been employed utilizing various imaging protocols. Clinicians use non-contrast CT, arterial phase and delayed phase CT, ultrasound, and various combinations based on personal experience and patient pathology. Concerns over cost, potential nephrotoxicity of contrast agents and repeated radiation exposure has led to investigation of alternate imaging modalities such as contrast-enhanced ultrasound (CEUS). CEUS represents an improvement of ultrasound imaging but comparisons against CT report widely varying results, likely due to technical factors of CEUS and limitations of single-phase CTA. Contrast ultrasound has been used effectively to diagnose leaks in the aorta post repair and is without the radiation and potential nephrotoxicity of iodinated contrast. Of yet, no large prospective studies have compared CT and contrast US and no studies have looked at the more complicated staged or fenestrated repairs. This study proposes to perform a contrast ultrasound at the same time as a contrast CT using a standardized protocol. This protocol would include a non-contrast CT, angiographic CT, and a CT in a delayed phase in all patients as standard of care. We will compare the results of a contrast US with the various data derived from a three phase CT.

NCT ID: NCT04551183 Withdrawn - Clinical trials for Abdominal Aortic Aneurysm (AAA)

Comparative Study of a Software With the Gold Standard

Start date: March 1, 2020
Phase: N/A
Study type: Interventional

Nurea wants to set-up a pivotal phase clinical study for its software PRAEVAorta, a decision-making support for diagnosis and follow-up of abdominal aorta aneurysm. This study is a comparative study. Its purpose is to demonstrate the adequacy of PRAEVAorta to the current Gold Standard in the care of patients with abdominal aortic aneurysm. The currently benchmark methods are the maximal diameter method (Hand-held measurement of maximum diameter on scan images) and the segmentation method for the aneurysm volume (manual segmentation of scan images, then calculation of the AAA volume by counting the pixels). The hypothesis is that 90% of the segmented patients have a volume ratio and a diameter ration equal to or greater than 90%.

NCT ID: NCT04197648 Withdrawn - Clinical trials for Thoracic Aortic Aneurysm

Effects of Exercise on Thoracic Aneurysms

EXTRA
Start date: January 2023
Phase: N/A
Study type: Interventional

Thoracic aneurysm incidence is estimated to 4.5 cases per 100 000. The manifestation as well as natural history of thoracic aneurysm depend on many factors such as its localisation, its diameter, presence of collagen disease and family history. For the ascendant aortic aneurysm, it is often linked to a degeneration of the media arterial layer of the arterial wall. The media degeneration is cause by the degeneration of the elastic fibres, which lead to a weakening of the arterial wall accompanied with dilation. This process is often due to age and is accelerated by high blood pressure. Amongst the numerous factors causing the aneurysm, the investigators find: hypertension, aortic bicuspid valve, smoking, atherosclerosis, trauma and genetic predisposition. The average growth rate of thoracic aneurysm is 0.1-0.2 cm/year. The risk of rupture is associated to the size of the aneurysm as well as patient's symptoms. The ruptures and dissections rates are accounted for 2-3/year for thoracic aneurysm between 5.5-6.0 cm in diameter. The patients are often limited in their daily life activities considering their concern and risk of rupture and/or dissect. The effects of exercise on the progression of the aneurysm dilation in patients with thoracic ascendant aortic aneurysm are unknown. It is well known that high blood pressure is a risk factor for rupture of the aortic aneurysm. Many studies have demonstrated the benefits of physical exercise regarding the lowering impact of blood pressure in a cardiac hypertensive population. At 3 and 6 months of the intervention, the subjects in the exercise group will have: 1) a lowered blood pressure at rest and during exercise, 2) maintenance/ improvement of muscle strength, 3) improvement of aerobic exercise capacity (VO2max), and 4) aortic dilation that remained stable or comparable to the control group. The research objective is to measure and compare to a control group, the effects of an exercise program on the following parameters: blood pressure response at rest and during exercise, as well as the VO2max at 3 and 6 months time of the intervention. This randomised and prospective study will take place at the " Institut Universitaire de Cardiologie et de Pneumologie du Québec (IUCPQ) " and will include patients who have a non-surgical ascendant thoracic aortic aneurysm (ATAA). The selected subjects will be randomised into two groups: 1) exercise group (n=15), and 2) control group (n=15). Both groups will be met prior to the intervention (baseline) and at 3 and 6 months time of the intervention, and measures described below will be recorded.

NCT ID: NCT03965364 Withdrawn - Clinical trials for Abdominal Aortic Aneurysms

China Post-market Study of the INCRAFT® AAA Stent Graft System in Subjects With Abdominal Aortic Aneurysms (INITIATION)

Start date: August 31, 2019
Phase:
Study type: Observational [Patient Registry]

INITIATION is a postmarket clinical follow-up study in China. The purpose of the study is to continue to evaluate the safety and effectiveness/performance of Incraft in subjects with abdominal aortic aneurysms requiring endovascular repair in routine clinical practice. Approximately 120 subjects will be enrolled and followed through 1-years postprocedure. Up to 20 sites in China may participate.

NCT ID: NCT03763812 Withdrawn - Clinical trials for Abdominal Aortic Aneurysm

Post Implant Syndrome After EVAR and EVAS (INSPIRE Study)

Start date: December 2019
Phase: N/A
Study type: Interventional

Retrospective data have shown that active sac management, as applied in EVAS, reduces the incidence of the post-implant syndrome. All-cause and cardiac mortality at one-year seems to be lower after EVAS when compared to EVAR. Ongoing, low grade, inflammation could differ between techniques and induce cardiac damage. This study is designed to establish whether EVAS results in a reduced post-operative inflammatory response during the first year after surgery, compared to EVAR as assessed by trends in circulating inflammatory cytokine concentration. Study design: International prospective, comparative, explorative study. Study population: Patients scheduled to undergo infra-renal EVAR with a polyester endograft or EVAS for an infrarenal aortic aneurysm. This is an explorative study and therefore only patients who would normally receive a suitable device as part of standard treatment at the participating institutes will be recruited. Blood samples will be taken at specified time points before and after surgery. Main study parameters/endpoints: The difference in early post-operative and long term inflammatory response between EVAS and EVAR, measured by the incidence of the post-implant syndrome. To investigate the incidence of the post-implant syndrome, the rise in CRP, WBC and circulating cytokines, at specified time points up to 12 months after surgery and the change in aortic thrombus volume and its relationship with the inflammatory response, measured by cytokines' concentrations.

NCT ID: NCT03738124 Withdrawn - Clinical trials for Aortic Aneurysm, Thoracic

Evaluation of the Valiant Mona LSA Thoracic Stent Graft System in Thoracic Aortic Aneurysms and Chronic Dissections

MONA-LSA
Start date: January 2019
Phase: N/A
Study type: Interventional

To ensure adequate seal of currently available stent grafts, a proximal 20 mm of healthy aorta is recommended. Extending the proximal landing zone into the arch by intentional covering of the left subclavian artery (LSA) without revascularization expose to serious neurologic complications. Serious risks are also known to accompany subclavian revascularization. The Valiant Mona LSA Thoracic Stent Graft System (Medtronic,Santa Rosa, Calif) consists of a main stent graft and a branch stent graft designed to maintain LSA patency. The purpose of this study is to characterize the safety and effectiveness of this device for the treatment of Aneurysms and chronic Type B dissections of the arch.

NCT ID: NCT02995642 Withdrawn - Clinical trials for Aortic Aneurysm, Abdominal

Targeted PET/CT and PET/MRI Imaging of Vascular Inflammation

Start date: October 2019
Phase: Phase 2
Study type: Interventional

Stroke and abdominal aortic aneurysms (AAAs) are common and highly lethal vascular diseases. Angiogenesis and infiltration of inflammatory cells such as macrophages may cause stroke and AAAs. The purpose of this study is to test PET/CT and PET/MRI imaging to specifically detect those diseases using a new developed agent (18F-FPPRGD2) that can target angiogenesis and macrophages.

NCT ID: NCT02894749 Withdrawn - Clinical trials for Aortic Aneurysm, Abdominal

Evaluation of 3D Rotational Angiography After EVAR

EVAR
Start date: August 2017
Phase: N/A
Study type: Interventional

This is a randomized prospective monocentric study to evaluate the benefits of a 3D rotational acquisition (3DRA) to assess technical success after treatment of infra-renal aneurysm with bifurcated endograft. Patients will be randomized between the standard strategy (2D angiography at the end of the procedure and angioCT-scan before discharge) and the new strategy (3DRA at the end of the procedure). Expected findings are a reduction of radiation exposure and contrast medium used during the hospital stay, with a similar resolution between angioCT-scan and 3DRA to depict the main complications after EVAR (occlusion, kinking, endoleak). Furthermore, any complication depicted after 3DRA group could benefit from an additional procedure during the same operating time, and therefore avoid a second intervention for the patient.

NCT ID: NCT01480531 Withdrawn - Aorta Aneurysm Clinical Trials

Pre and or Post Operative Blood Pressure Control With Clevidipine (Cleviprexm Medicines Company) in Aortic Aneurysm / Dissection

Clevidipine
Start date: December 2011
Phase: N/A
Study type: Interventional

2. Purpose of the Study - 1. To determine the feasibility of Clevidipine use for rapidly achieving and maintaining individually specified patient BP target ranges in the pre and postoperative periods of aortic aneurysm and dissection management. 2. To determine the safety of Clevidipine use in the pre and postoperative periods of aneurysm and dissection management 3. Background & Significance - Surgical treatments for persons with aortic root/arch dissection or aneurysm have significantly improved survival. However, critical in management of these patients is precise control of blood pressure (BP). With increasing BP, both acute and chronic, the risk of fatal and nonfatal vascular complications is imminent. Similarly, with excessive lowering of arterial pressures, cerebral, spinal cord, cardiac, and renal ischemic hypoperfusion is also noteworthy. Typically, the target systolic blood pressure range for these patients is 100-120 mmHg. Several different classes of vasoactive agents are in current use to acutely manage BP but none possess the optimal profile of an ideal vasodilator. Notable limitations include inadequate potency, slow onset and offset of action, multiple receptor function, safety concerns and, importantly, restricted/ineffective titration, which results in clinically significant hemodynamic and cardiovascular perturbations. Recently, the ultra short-acting intravenous dihydropyridine calcium-channel blocker clevidipine (Cleviprex, The Medicines Company) was approved for management of BP in critical care settings. Clevidipine's pharmacology lends itself to acute management of BP in a broad critical care setting in both surgical and nonsurgical patients. In the current study, the investigators propose to further characterize the hemodynamic effect of CLV in the pre and post-operative management of BP in patients with aortic aneurysm/dissection. 4. Design & Procedures Eligible patients will be approached to participate in the study by the Intensive Care Unit (ICU) attending and/or by a cardiothoracic surgical/anesthesiology fellow or a cardiac research nurse. All aspects of clinical management and monitoring will be according to standard practice that includes: - ECG - Oxymetry - Temperature - Invasive arterial blood pressure - Recording of routine laboratory results - Imaging studies including CT/MRI (A)/ Echocardiography - Pulmonary artery catheter (postoperative patients) - Mechanical ventilation (postoperative patients) - According to established protocol for acute intravenous management of arterial blood pressure in these patients, an upper and lower threshold of systolic blood pressure will be prescribed by the attending physician (the range being (100 mmHg -120 mm Hg SBP). Hemodynamic data will be collected continuously via a bedside laptop as well as pertinent clinical data and information about efficacy and safety will be recorded. • Subjective evaluation of efficacy of CLV (questionnaire format to be completed by the critical care team)