Clinical Trials Logo

Clinical Trial Summary

This trial is conducted to assess the performance and handling of the in vitro diagnostic (IVD) device for oral direct factor Xa and thrombin inhibitors from urine samples of patients on treatment with direct oral anticoagulants Apixaban, Edoxaban, Rivaroxaban, and Dabigatran (DOAC) in an actual point-of-care (POCT) setting in comparison to results obtained by liquid chromatography tandem mass spectrometry (LC-MS/MS) from urine samples. This trial is conducted to assess the performance and handling of the IVD for oral direct factor Xa and thrombin inhibitors from urine samples of patients on treatment with DOACs in an actual point-of-care setting in comparison to results obtained by liquid chromatography tandem mass spectrometry (LC-MS/MS) from urine samples. "publication Thromb Haemost. 2019 Nov 8. doi: 10.1055/s-0039-1700545. [Epub ahead of print]"


Clinical Trial Description

This prospective, open-label, controlled, not randomized Performance Assessment will be conducted as a multicenter Performance Assessment in Germany. The trial investigates the sensitivity and specificity of a POCT for DOAC, i.e., the rate of correct positive, false positive, correct negative and false negative results in the point-of-care setting. The IVD is a test to determine absence or presence of DOAC in urine - Test A tests for oral direct factor Xa inhibitors (rivaroxaban, apixaban, and edoxaban), Test B for oral thrombin inhibitors (dabigatran). Two groups of patients will be included: - Test group A: Patients under therapy with oral direct factor Xa inhibitor (rivaroxaban, apixaban, and edoxaban) (n=440) - Test group B: Patients under therapy with oral thrombin inhibitors (dabigatran) (n=440) No control group of patients not treated with a DOAC is required, as patients take either oral direct factor Xa inhibitors (Test group A) or oral thrombin inhibitors (Test group B), never both. Thus, patients in Test group A are negative for oral thrombin inhibitors and can serve as negative control for Test group B, and vice versa. The point-of-care test (POCT) is a color-indicator diagnostic medical urine dipstick test for assessing the presence of oral direct factor Xa inhibitor (rivaroxaban, apixaban, and edoxaban) and thrombin inhibitors (dabigatran). The principle of the diagnostic test is based on the development of different colors on the indicator part of the dipstick in the presence or absence of oral direct factor Xa (rivaroxaban, apixaban, and edoxaban) and thrombin inhibitors (dabigatran). The colors for the test were chosen so that they could easily be read by the naked eye, with little possibility of incorrect identification of colors. The results for presence or absence will be compared with the concentration of DOAC analyzed by LC-MS/MS. Two groups of medications (thrombin inhibitors, factor Xa inhibitors) will be tested with the IVD and test results compared to bioanalytical results in urine. The objective of the investigation is to show that the proportion of false negative and false positive tests with the IVD is below 5%. The required sample size to show that the assumed rate of 2.5% false-negative/false-positive tests is statistically significant lower than 5% would require 384 patients per each test group, with α=0.05 and β=0.20 (80% power). Accounting for a potential drop-out rate of 12%, a sample size of n=440 patients per test group was considered adequate to demonstrate adequate performance of the IVD. This sample size has been assessed with the SAS procedure PROC POWER (SAS Institute Inc., Cary, NC, USA, release 9.3) using the ONESAMPLEFREQ statement under the assumption that the test will be conducted as a 1-sided test with a null proportion of 0.05. For each diagnostic test the proportions of false negative and false positive results will be assessed together with confidence intervals. The urine concentration serves as a gold standard. Furthermore, McNemar tests will be conducted in order to compare the sensitivity, the specificity, accuracy, negative predictive value, positive predictive value and likelihood probability of the two different medications. Kappa coefficients will be calculated in order to quantify the strength of agreement between two diagnostic test methods. As the study design is not randomized the two groups will be compared according to biographic data (i.e. age, gender, concentration in urine) by common statistical tests (Chi2 test, t-test) in order to investigate their equality. In the case of differences between groups statistical adjustment will be done (i.e. propensity score) in order to avoid the influence of a bias. The Performance Assessment will be conducted at the patient's family doctor or medical practice/outpatient care unit (referred to as "investigational site" in the following). The Performance Assessment will consist of a single visit, which is performed during a routine visit at the investigational site. The Performance Assessment starts with first patient signing informed consent (FPFV) and ends with the last patient providing the last sample (last patient last visit, LPLV). "publication Thromb Haemost. 2019 Nov 8. doi: 10.1055/s-0039-1700545. [Epub ahead of print]" ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03182829
Study type Observational
Source Doasense GmbH
Contact
Status Completed
Phase
Start date August 22, 2018
Completion date June 5, 2019

See also
  Status Clinical Trial Phase
Not yet recruiting NCT05361889 - ReAl-life multIceNter Outcomes Registry for Better antithrOmbotic Strategies in Patients With AF (RAINBOW-AF)
Completed NCT03143569 - Ventricular Assist Device Anti-Factor Xa (VAD ANTIX) Monitoring Study: a Prospective Randomized Feasibility Trial N/A
Recruiting NCT05486351 - Keeping Oral o Parental AnticoaguLation in the Acute Phase of Cardioembolic Ischemic Stroke
Completed NCT04623177 - Thromboprophylaxis for Patients in ICU With COVID-19
Active, not recruiting NCT05491460 - Pharmacokinetics and Point of Care Testing of Direct Oral Anticoagulants Subjects Phase 1
Withdrawn NCT01541098 - A Clinical Study of Lyophilized Plasma in Patients on Warfarin Phase 2
Completed NCT04351438 - Evaluation of Complication Rates Using Filter vs. Centrifuge and Heparin vs. Citrate Anticoagulation
Recruiting NCT05181774 - Prediction of Bleeding Risk After Anticoagulant Therapy for Atrial Fibrillation Based on Proteomics and Metabolomics