Anterior Cruciate Ligament Clinical Trial
Official title:
The Long-term Degradation Outcome of Bilok Biodegradable Interference Fixation Screws Used for Bone-Patellar Tendon-Bone ACL Reconstruction
The purpose of the study is to evaluate the long term outcome of a poly L-lactic acid / β-tricalcium phosphate (BILOK) biodegradable interference fixation screw used for arthroscopic bone-patellar tendon-bone ACL reconstruction,to determine if these BILOK screws completely biodegrade as expected three years after implantation, and to determine whether there is bone ingrowth into the defect remaining after resorption of the BILOK screw.
BILOK screws have been used for ACL interference fixation in the US since the late 1990s. As yet, there are no long-term studies to demonstrate the eventual biologic outcome of these devices. Animal studies indicate that the material used in BILOK implants completely degrades after 3 years, but these reports do not indicate what takes their place. Reports of other screw materials indicate that pure PLLA screws remain intact and can be removed whole at revision surgery in the first few months to years after implantation. Recently a report of a biopsy at 2 years after surgery indicated that whole fragments of a PLLA screw were observed. Schwach and Vert suggested that a PDLLA screw (combination of dextro and levo stereoisomers) completely degrade and is replaced by bone 3 years after surgery in sheep but no information is available for the human. In addition to being limited and anecdotal, most studies evaluating the degradation of biodegradable screws used in humans are conducted using plain radiographs and MRI to evaluate the status of the biodegradable screws. A report by Bach et al evaluated the MRI appearance of a biodegradable interference screw composed of a different polymer (polyglycolic acid 67% and trimethylene carbonate 33%) in eight patients at 2 years. It showed the reabsorption of the screw but suggested that MRI is not the most effective method for determining the bone ingrowth status in the area of the resorbed screws. CT scanning is a better methodology than MRI for this application and was recently used to study the disappearance of a pure PLLA screw at least 7 years after implantation. The purpose of this study is to evaluate the long-term resorption status of a Bilok screw and determine, using CT scan, what material replaces the screw. ;
Time Perspective: Prospective
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT00492609 -
Medical and Economical Evaluation of Computer-assisted Reconstruction of the Anterior Cruciate Ligament (ACL)
|
N/A | |
Recruiting |
NCT05470790 -
Arabic Version of Marx Activity Rating and Knee Stability in Sports/Cutting-Pivoting Ability Scales
|
||
Completed |
NCT01194505 -
Ultrasound Guided Obturator Nerve Block for Anterior Cruciate Ligament Reconstruction (ACL)
|
N/A | |
Completed |
NCT01148784 -
Comparison of Doubled Quadrupled Versus Quadrupled Allograft Tissue Constructs for Anterior Cruciate Ligament (ACL) Reconstruction
|
N/A | |
Active, not recruiting |
NCT00490594 -
SeriACL™ Device Trial for Anterior Cruciate Ligament (ACL) Reconstruction
|
Phase 1 | |
Terminated |
NCT01919658 -
Effects of Femoral vs Saphenous Nerve Blocks on Function After ACL Repair
|
N/A | |
Terminated |
NCT00717171 -
Efficacy of the SurgiStim3 Electrical Stimulation Device in Persons Undergoing Anterior Cruciate Ligament Repair
|
Phase 4 | |
Recruiting |
NCT05799235 -
Telerehabilitation for Anterior Cruciate Ligament Reconstruction - TAR Program in Adolescents
|
N/A | |
Completed |
NCT02895607 -
Evaluation of Outpatient Surgery in the Anterior Cruciate Ligament Reconstructions With Hamstring Hospital
|
||
Completed |
NCT03429140 -
Early Anti-inflammatory Treatment in Patients With Acute ACL Tear and Painful Effusions
|
Early Phase 1 |