Clinical Trials Logo

Clinical Trial Summary

Purpose:

To evaluate short-term angle opening after argon peripheral iridoplasty using AS-OCT and to report its complications at 1-week and 1-month follow up in patients that did not achieve a satisfactory clinical angle opening despite patent laser peripheral iridotomy.

Design:

Prospective, Interventional case series

Subjects:

Patients with an occludable angle in more than two quadrants in dark room indentation gonioscopy and patent iridotomies of at least 2 weeks, with assessment of persistent angle closure aetiology by ultrabiomicroscopy and A-scan ultrasound are included.

Patients will undergo complete examination and AS-OCT before ALPI, one week and one month after it. We analyzed the images in a masked manner and took the angle measurements (AOD500, AOD 750, TISA500, TISA750, ARA500, ARA 750, Lens vault) at 0° and 180° as the main outcome measure to determine effectiveness.


Clinical Trial Description

Background Argon laser peripheral iridoplasty (ALPI) (Figure 1) is an iris-remodeling procedure that intends to widen the iridocorneal angle through redistribution of peripheral iris tension forces close to the trabeculum.

ALPI is effective in patients with plateau iris syndrome and acute angle closure glaucoma but there is less published about its effectiveness in secondary angle closure. Therefore, we are going to evaluate this procedure in those patients that did not achieve a satisfactory clinical angle opening despite patent laser peripheral iridotomy, as long as there was no contraindication for a new laser procedure and provided that cataract surgery is not viable, as in clear lens or patients not willing to undergo surgery.

To evaluate its effectiveness, we will use a non-invasive non-contact method through anterior segment optical coherence tomography (AS-OCT), which transmits and receives light in an ultrasound-like manner to obtain anterior segment imaging that helps to evaluate the angle more objectively.

Purpose To evaluate short-term angle opening after argon peripheral iridoplasty using AS-OCT and to report its complications at 1-week and 1-month follow up in patients with persistent angle closure despite patent iridotomies.

Study Design Prospective, interventional case series Patients with an occludable angle in more than two quadrants in dark room dynamic gonioscopy and patent iridotomies of at least 2 weeks were included. A supplemental diagnosis regarding the etiology of persistent angle closure by ultrabiomicroscopy and A-scan ultrasound will be obtained. Patients who presented with these criteria to the angle closure clinic at the glaucoma service of our institute (Instituto de Oftalmologia Fundacion Conde de Valenciana IAP, Mexico City) between July and November 2012 were included.

Patients with synechiae of more than one quadrant, advanced glaucomatous damage, prompt cataract surgery plans and those who did not wish to participate were excluded.

After obtaining informed consent, patients underwent biomicroscopy, gonioscopy, visual acuity, intraocular pressure and AS-OCT before ALPI, one week and one month after it. The AS-OCT Visante (Carl Zeiss Meditec, Dublin) took an image of the vertical and horizontal meridians at the same room illumination of 14 lux measured with a luxometer mobile application (Apple Inc., Application Manufactory available at the AppStore by June 2012).

Images were analyzed in a masked manner marking scleral spurs and angle recess at 0° and 180° of the horizontal image.

ALPI was applied with a VISULAS diode laser of 532 nm (Carl Zeiss Meditec, Dublin, CA) by the same ophthalmologist (JML). Twenty to 40 spots of 400 mW power with 500 microns of size and duration of 500 ms were applied. Power was modified arbitrarily until an effective iris contraction was obtained. It was considered an effective contraction as that which causes a concentric movement around the laser spot, with minimal iris pigmentation and immediate angle opening observed through the lens mirrors using a Goldmann lens. Power was lowered if there was any bursting sound perceived, pigment dispersion, air bubbles or considerable pain. Pilocarpine was not applied before the procedure in all cases because some eyes had angle closure secondary to ciliary block and we considered it could worsen the closure in many cases.

Topical prednisolone acetate was applied every 4 hours for 1 week and brimonidine tartrate every 12 hours for 1 week . ;


Study Design

Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Single Blind (Outcomes Assessor), Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT02199158
Study type Interventional
Source Instituto de Oftalmología Fundación Conde de Valenciana
Contact
Status Completed
Phase N/A
Start date July 2012
Completion date January 2013

See also
  Status Clinical Trial Phase
Recruiting NCT06000865 - Glaucoma Rehabilitation With Action viDeo Games and Exercise - GRADE N/A
Recruiting NCT06278597 - Automatic Evaluation of the Anterior Chamber Angle Width by a New Non-contact Optical Device N/A
Active, not recruiting NCT04271709 - Manhattan Vision Screening and Follow-Up Study (NYC-SIGHT) N/A
Recruiting NCT03274024 - The Asia Primary Tube Versus Trab (TVT) Study N/A
Completed NCT04552964 - Assessment of the Impact of an add-on and Its Smartphone Application on the Daily Management of Glaucoma N/A
Recruiting NCT01957267 - Functional and Structural Imaging for Glaucoma
Active, not recruiting NCT04624698 - iStent Inject New Enrollment Post-Approval Study N/A
Completed NCT04020705 - The Efficacy of Citicoline in Eyedrops (OMK1) in Reducing the Progression of Glaucoma N/A
Completed NCT03150160 - Additive Effect of Twice-daily Brinzolamide 1%/Brimonidine 0.2%Combination as an Adjunctive Therapy to Travoprost in Patients With Normal Tension Glaucoma Phase 4
Not yet recruiting NCT05581498 - Glaucoma Exercise as Medicine Study (GEMS). N/A
Recruiting NCT02921568 - Side-by-Side Comparison of P200TE and Spectral OCT/SLO on Diseased Eyes N/A
Active, not recruiting NCT02901730 - Clinical Study of LPI With Different Laser Wavelengths N/A
Completed NCT02955849 - A Trial of China Laser and Surgery Study Glaucoma in Rural China Early Phase 1
Recruiting NCT02554214 - Pilot Clinical Trial on a New Adjustable Glaucoma Drainage Device N/A
Recruiting NCT02471105 - Investigation of IOP and Tolerability of Bimatoprost 0.01% and Tafluprost Unit Dose Preservative Free 15 Microgram/ml Phase 4
Active, not recruiting NCT02390284 - Stop Retinal Ganglion Cell Dysfunction Study Phase 3
Completed NCT02390245 - Philadelphia Telemedicine Glaucoma Detection and Follow-Up Study N/A
Completed NCT02246764 - Study of Netarsudil (AR-13324) Ophthalmic Solution in Patients With Glaucoma or Ocular Hypertension Phase 3
Completed NCT02628223 - 180 Degree vs. 360 Degree Selective Laser Trabeculoplasty as Initial Therapy for Glaucoma N/A
Completed NCT02653963 - Triamcinolone for Ahmed Glaucoma Valve N/A