Clinical Trials Logo

Clinical Trial Summary

The ultimate purpose is to explore the potential techniques to exclude aneurysms and provide an alternative conduit for arterial flow. The single center sponsorship is intended to provide the investigators the potential to incorporate improvements in existing technology during the course of the study thereby ultimately enhancing the potential for superior medical care of patients suffering from these disease states. The sponsor/investigator recognizes and accepts responsibility to notify and receive approval from the agency when device modifications are made that may affect patient safety.


Clinical Trial Description

The Arizona Heart Institute is respectfully submitting this protocol for a feasibility study utilizing the endoluminal grafts constructed of PTFE encapsulated nitinol stents. The study is intended to evaluate the use of this unique device in the treatment of aortic aneurysmal disease. The stent graft is made by laminating a PTFE "jacket" around nitinol stents which act as structural and fixation supports. Both materials have an extensive history of use in various types of implanted devices. CT scans and angiography or 3D computer imaging, and possibly IVUS imaging will be used to choose the sites for placement of the devices and to assure precise deployment.

In comparison to the conventional surgical approach, endoluminal stent-graft techniques for repair of abdominal aortic aneurysms (AAAs) offer the advantages of a minimally invasive procedure with lower morbidity and perhaps cost reduction. The Arizona Heart Institute has a long history in the area of endoluminal grafting for treatment of aneurysms and occlusive disease. Endoluminal sleeves principally using ePTFE and both stainless steel and nitinol stent structures have been studied using commercially available materials customized for particular pathologic situations. As the technology advances however, sophisticated engineering beyond the capabilities of our institution was required.

The proposed project originates because of the potential to escalate the combination of ePTFE and stents to a higher level of performance in aneurysm exclusion procedures. Current data reflect several deficiencies in approved exclusion devices. Migration, types I, II and III endoleaks and continual aneurysm expansion are clear predictors for potential ruptures. Increased complications associated with the initial peri-procedural deployment as devices are released on a broader scale have been observed. In order to address these problems, the Arizona Heart Institute has engaged EndoMed engineering to design the endoluminal graft to repair abdominal aortic aneurysms. We believe this will result in a positive step forward in the technology to exclude aneurysmal disease less invasively.

The endoluminal stent-graft is composed of multiple nitinol stents which are encapsulated in expanded Polytetrafluoroethylene (ePTFE). The stents are composed of a Z-shaped, performed nitinol wire, which is crimped together with a stainless steel sleeve to form the circular frame of the graft. This frame is then encapsulated between two thin sheets of laminated PTFE. The proximal end of the endoluminal stent-graft is made in two configurations. One is a completely encapsulated graft where the PTFE covers the entire device. The other has an open stent segment (bare wire configuration) that allows the open stent region of the graft to be placed across the orifice of the renal, mesenteric, or internal iliac arteries without obstructing antegrade blood flow. The device will be available in a straight tube, aortomonoiliac or bifurcated design.

Once the endoluminal stent graft is built, a 4 French guidewire dilator is placed through the center of the graft and the assembly is compressed into a high density polyethylene (HDPE) cartridge for ease of intraluminal delivery. The endoluminal stent-graft is then placed in two Tyvek pouches and sterilized using Hydrogen Peroxide.

Subjects will undergo an evaluation of the PTFE encapsulation of Nitinol stents to provide data on the device's feasibility for therapeutic clinical use. Follow-up will be completed at 1, 6, 12, 24, 36, 48, and 60 months. Subject evaluation at 1 month will include a Complete History and Physical, Bilateral ABIs, Abdominal Duplex Ultrasound, and a KUB X-ray (4 views). Subject evaluation at 6 months will also include a Complete History and Physical, Bilateral ABIs, Abdominal Duplex Ultrasound, KUB X-ray (4 views), and based on the duplex ultrasound an Abdominal CT scan with and without IV contrast 2.5 mm and Labs (BUN/Creatinine). Subject evaluation at 12, 24, 36, 48, and 60 months will include a Complete History and Physical, Bilateral ABIs, Abdominal CT scan with and without IV contrast 2.5 mm, Abdominal Duplex Ultrasound, KUB X-ray (4 views), and Labs (BUN/Creatinine). ;


Study Design

Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT00549016
Study type Interventional
Source Arizona Heart Institute
Contact Russell Williams
Phone 602-266-2200
Email rwilliams@azheart.com
Status Recruiting
Phase N/A
Start date November 2002
Completion date November 2012

See also
  Status Clinical Trial Phase
Not yet recruiting NCT06235619 - Arch Size Study for Anatomical Variations
Completed NCT01178710 - Effect of Simvastatin on Cardiac Function N/A
Not yet recruiting NCT00905931 - Lycopene Following Aneurysmal Subarachnoid Haemorrhage Phase 2
Completed NCT00349908 - A Feasibility Study of the Cordis Neurovascular Self Expanding Stent System in Intracranial Arteries Phase 1
Not yet recruiting NCT05831202 - SEALâ„¢ IT: Saccular Endovascular Aneurysm Lattice System Interventional Pivotal Trial Phase 3
Recruiting NCT03285100 - The Effects of Discontinuation of Vitamin K Antagonists on the Rate of Elastin Degradation N/A
Recruiting NCT06189950 - Registration Trial of the Intracranial Visualized Stent for the Wide-necked Intracranial Aneurysms:REBRIDGE N/A
Active, not recruiting NCT04592185 - The Study of the Fenestrated Anaconda Device in the Treatment of Abdominal Aortic Aneurysms
Completed NCT01970605 - Silver Graft All Comers Registry
Completed NCT00282893 - Balloon Prophylaxis of Aneurysmal Vasospasm Phase 2
Active, not recruiting NCT00549380 - Clinical Study of Aneurysm Exclusion Phase 1
Completed NCT04598802 - COvera in BRAnch Registry
Completed NCT04246125 - Patient Skin Dose in Interventional Radiology
Recruiting NCT05829746 - PROSPECTIVE, MULTI-CENTER, OPEN-LABEL, SINGLE-ARM REGISTRATION TRIAL OF THE TUBRIDGE FOR THE TREATMENT OF WIDE-NECKED SMALL AND MEDIUM-SIZED INTRACRANIAL ANEURYSMS N/A
Completed NCT03242343 - VasQ External Support for Arteriovenous Fistula N/A
Recruiting NCT02878967 - Standardized Long Term Follow-up of Patients After Endovascular Embolization of a Brain Aneurysm
Active, not recruiting NCT02345005 - Iliac Branch Excluder ReGistry (IceBERG)
Recruiting NCT02167997 - EffectiveNess and SAfety of Small ANeurysm COiling Trial N/A
Completed NCT02848612 - Evaluation of the Amiens University Hospital Neuroradiology Anticoagulation Protocol
Enrolling by invitation NCT04269447 - Prospective Aortic Biobank of POP-STAR