Aneurysm, Intracranial Clinical Trial
Official title:
An Early Feasibility Study Assessing the Safety, Technical Performance, and Efficacy of the Electrolytic eCLIPs Bifurcation System for the Treatment of Intracranial Bifurcation Aneurysms
The purpose of this study is to investigate the feasibility and initial clinical safety of eCLIPs device use for the treatment of wide-necked bifurcation aneurysms. The eCLIPs device is a novel shield like implant that is placed across the neck of the aneurysm and not only facilitates coil retention but also partly obstructs the flow of blood into the aneurysm. This is an early feasibility study, which is a small study investigating an innovative device to gather more clinical data before conducting a larger study. The safety and the effects of the device on the aneurysm will be studied for 12 months after the procedure among 15 patients at approximately 4 participating hospital centers. A larger study will be required to determine the safety and efficacy of the eCLIPs device for the treatment of wide-necked bifurcation aneurysms.
The primary objective of this study is to obtain preliminary confirmation that the eCLIPs Delivery Wire is safe and provides sufficient technical performance in delivering the eCLIPs Implant to distal tortuous anatomies. This study will be a multicentre, open label, single-arm safety, technical performance, and efficacy study of the Electrolytic eCLIPs Bifurcation System in the management of bifurcated intracranial aneurysms (IA). Subjects included in the study will have saccular intracranial aneurysms that arise at or adjacent to a bifurcation, having a neck length of ≥ 4mm or have a dome:neck ratio <2. Aside from the implantation of the eCLIPs Implant, the study will follow usual clinical care practices. The subjects will undergo clinical assessments at pre-discharge and 30 days, as well as clinical assessment and radiographic imaging at 6 and 12 months (Digital Subtraction Angiography; DSA). It is important to note that changes to the investigational device may occur during the course of this early feasibility study. Ongoing results of the study will be evaluated, along with collection of detailed operator feedback on usability, in order to determine whether further refinements to the eCLIPs Delivery Wire are required. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT03117803 -
The Natural Course of Unruptured Intracranial Aneurysms in a Chinese Cohort
|
N/A | |
Terminated |
NCT05544045 -
China Surpass Streamline Post-Market Study
|
||
Not yet recruiting |
NCT02820779 -
New Covered Stent (Willis) for the Endovascular Reconstruction of Intracranial Vessel Wall Defects Registry
|
N/A | |
Active, not recruiting |
NCT04195568 -
Evaluation of Safety and Effectiveness of Stryker Surpass Evolve™ Flow Diverter System
|
N/A | |
Recruiting |
NCT05029947 -
Setting Benchmarks for Microsurgical Clipping of Unruptured Intracranial Aneurysms
|
||
Recruiting |
NCT04852783 -
US IDE Study of the Contour NEurovasCular System™ for IntraCranial Aneurysm Repair
|
Phase 4 | |
Completed |
NCT02354300 -
Transcranial Doppler Ultrasound Monitoring During Flow-Diverter Embolization
|
N/A |