View clinical trials related to Anaesthesia.
Filter by:Melatonin has been proposed as alternative to midazolam as a premedication in procedures preceding anaesthesia induction. The objective of this prospective, randomized, double-blind study is to investigate the possible effect of melatonin premedication on the required infusion of propofol in comparison to midazolam, evaluating the efficacy of oral melatonin on sedation in children undergoing surgery. Preoperative anxiety and postoperative analgesia are also assessed in both groups.
A primary aim of anaesthesia is to prevent awareness of surgery; ablation of the experience of surgery is the most secure way to prevent awareness with recall. Fortunately the incidence of awareness with recall (the patient can spontaneously remember the intraoperative event) is very rare (0.1-0.2%). However the investigators systematic review suggests that consciousness of intraoperative events may occur in approximately 37% of patients in experimental studies (as identified by the validated clinical procedure the isolated forearm test that does not require postoperative recall of the event). In this international cohort study, recruiting a minimum sample of 200 patients, the investigators will investigate the incidence of anaesthesia awareness (as identified by the isolated forearm test) following the induction of anaesthesia and before surgery.
As a result of rises in living standards quality of life is progressively increasing. Combined with developments in anesthesia, surgical techniques and medication allowing more difficult and complicated interventions to be carried out, elderly patients are encountered more often in daily anesthetic practice.Reduced tone in the upper airway of geriatric patients increases the possibility of airway obstruction. In old patients with no teeth, sunken cheeks may make ventilation with a mask ineffective; perhaps even impossible. In addition to our observations that Laryngeal mask (LM) is more difficult to place in older patients, in the literature there are very few studies on the use of LM in older patients. Sixty percent of patients over the age of 65 have no teeth. Ventilation with a mask is more difficult for patients without teeth compared to those with teeth. Laryngeal mask is an alternative airway device for patients without teeth when the face mask does not sit correctly. The aim of this study is primarily to measure the success of placement on first try, ease and duration of insertion and oropharyngeal leak pressure of laryngeal mask Unique (LMU) in patients 65 years of age and above dentulous and edentulous elderly patients. The secondary aim is to compare the effects on the hemodynamic response occurring during placement.
With an aging population a prevalence of edentulous patients increased above 60 % among individuals aged ≥65 yr. Face mask ventilation of these edentulous patients is often difficult because of the inadequate fitting of the standard mask to the face. In addition, because of a reduction in muscle tone under general anesthesia, the air space in the oropharynx is reduced, and posterior displacement of the tongue, soft palate and epiglottis tend to close the airway. The laryngeal mask airway (LMA) provides a better alternative to the standard face mask if the facial contours of the patient are not suited to the standard face mask. It is more difficult to perform bag-mask ventilation in edentulous patients than in patients with intact dentition. The laryngeal mask airway (LMA) provides a better alternative to the standard face mask if the facial contours of the patient are not suited to the standard face mask. We aimed to compare the routinely used laryngeal mask airway in our clinic, the LMA Unique™ with the newly released LMA Supreme™ in edentulous elderly patients for the success in first attempt insertion, ease and time of insertion, and oropharyngeal leak pressure.
Laryngeal Mask is widely used for air-way management during anaesthesia. Pharyngolaryngeal morbidity linked to laryngeal mask use is related to correct choice of mask size, placement technique, placement of the laryngeal mask in the correct position on the larynx, cuff volume and cuff pressure. It has been stated that keeping laryngeal mask cuff pressure below 45 mmHg (60 centimeter of water(cmH2O) ) can prevent pharyngolaryngeal morbidity related to laryngeal mask (throat pain, dysphonia, dysphagia) and shown that using a manometer after Laryngeal Mask Unique placement to limit pressure within the cuff can reduce this morbidity by nearly 70%. Studies commenting on pharyngolaryngeal morbidity generally do not choose a certain age group and cover stages including very young and middle-aged groups. In the literature only one similar study on the geriatric age group was found. The aim of this study is to compare the postoperative pharyngolaryngeal morbidity in a group with cuff pressure held to 44 mmHg (60 cmH2O with a manometer and a group with Laryngeal Mask cuff inflated without reference to pressure in the geriatric age group with indications for Laryngeal Mask Unique placement.
Spinal anesthesia is widely performed using a surface landmark based 'blind' technique. Multiple passes and attempts while administering spinal anesthesia are associated with a greater incidence of post dural-puncture headache, paraesthesia and spinal hematoma. Real time and pre-procedural neuraxial ultrasound techniques have been used to improve the success rate of spinal anesthesia. The use of real time ultrasound-guided spinal anesthesia has to date been limited to case series and case reports.Its use may be limited by the requirement for wide bore needles and the technical difficulties associated with simultaneous ultrasound scanning and needle advancement. The use of pre-procedural ultrasound has been shown to increase the first pass success rate for spinal anesthesia only in patients with difficult surface anatomic landmarks. No technique has been shown to improve the success rate of dural puncture when applied routinely to all patients. Routine use of pre-procedure ultrasound guided paramedian approach results in 50% reduction in number of passes required for spinal anaesthetic, from a study at Cork University Hospital (awaiting publication). L5-S1 is the widest interlaminar space and provides minimal contribution to overall movement of lumbar spine.This interspinous space might still be accessible even if the patient has minimal spine flexion. We also noted that spinal needle insertion via the L5-S1 interspace was associated with the fewest passes in the pre-procedure guided ultrasound group (although non-significant). We hypothesise that the routine use of pre-procedural ultrasound-guided paramedian spinal technique at L5S1 interspinous space will result in fewer needle passes to enter the subarachnoid space when compared to the conventional landmark based midline approach.
This study aims to determine the impact of perinatal exposure to anaesthesia and analgesia on neurocognitive outcomes in early childhood by analyzing neurocognitive data already obtained from the local prospective observational cohort study: Growing up in Singapore Towards Healthy Outcomes (GUSTO). We hypothesize that: 1. Perinatal exposure to anaesthesia and analgesia is associated with poorer neurocognitive outcomes at 6, 18, 24 and 36 months. 2. Maternal anxiety and depression during the antenatal and post-partum period is associated with poorer neurocognitive outcomes at 6, 18 24 and 36 months.
Multiple passes and attempts while administering spinal anesthesia are associated with a greater incidence of post dural-puncture headache, paraesthesia and spinal hematoma. The investigators hypothesised that the routine use of pre-procedural ultrasound-guided paramedian spinals reduces the number of passes required to achieve enter the subarachnoid space when compared to the conventional landmark-guided midline approach.
Airway management is one of the basic topics in anesthetic practice. Use of endotracheal intubation and face mask are standard methods to maintain an open airway widely adopted for many years. As a result of a search for more appropriate choices from the point of view of effectiveness, reliability and side effects, supraglottic airway devices (SGAD) have been developed. SGAD's are used for thyroid surgery, ear surgery, carotid endarterectomy, adenotonsillectomy and laser pharyngoplasty, which require a variety of head-neck positions. Changing the head and neck position leads to changes in the shape of the pharynx, which causes variation in the cuff pressure and oropharyngeal leak pressure. Oropharyngeal leak pressure values play a determining role in protecting the airway from high cuff pressure. Additionally it shows that the laryngeal mask is correctly placed and is a sign of the effectiveness of positive pressure ventilation. During surgery head-neck and trunk position may change. As a result there is a need for research evaluating the effect of head and neck position on oropharyngeal leak pressure during SGAD use. AIM The aim of this study is to compare the effect of different head and neck positions on the oropharyngeal leak pressure in LMA-Unique and I-Gel applications. Additionally the placement duration, ease and success of these two supraglottic airway devices will be compared.
The Airtraq is a battery powered single use optical laryngoscope with a channel to hold and guide the tracheal tube into the trachea. It enables tracheal intubation in patients with normal and difficult airways, by enabling laryngoscopy without neck movement. As a single use device, it is cost effective to have these placed in emergency equipment kits, and for use by emergency and military personnel. However, it does have several limitations. The Airtraq requires the user to place his/her eye to the eyepiece in order to see the advancement of the laryngoscope and the tracheal tube, which may be difficult if the patient is on the ground or in emergency scenarios. Only the user can see through the eyepiece and any assistants are unable to view the larynx, this makes it difficult for assistants to help the operator. Many handphones now incorporate high quality cameras. In this study, we will evaluate the effectiveness of using the iPhone to aid laryngoscopy with the Airtraq optical laryngoscope during laryngoscopy and intubation in 30 patients presenting for elective surgery under general anaesthesia. We have manufactured an attachment that fits over the eyepiece of the Airtraq, to hold an iPhone to the eyepiece. This will enable to operator and assistants to simultaneously view the insertion of the Airtraq, view the larynx and view the passage of the tracheal tube into the trachea.