Clinical Trials Logo

Clinical Trial Details — Status: Enrolling by invitation

Administrative data

NCT number NCT06390033
Other study ID # ITS/133/21
Secondary ID
Status Enrolling by invitation
Phase
First received
Last updated
Start date June 30, 2023
Est. completion date June 30, 2024

Study information

Verified date April 2024
Source The Hong Kong Polytechnic University
Contact n/a
Is FDA regulated No
Health authority
Study type Observational

Clinical Trial Summary

The goal of this observational study is to evaluate and compare the performance of two prosthetic feet for unilateral transtibial amputees during both indoor and outdoor activities. The main research questions aim to answer are: 1. Can a low-cost prosthetic foot enhance gait mechanics and physical performance in individuals who have undergone traumatic unilateral transtibial amputation, as compared to the traditional K2 - K3 prosthetic feet currently available on the market, during both indoor and outdoor activities? 2. Can the low-cost prosthetic foot meet user satisfaction levels after traumatic unilateral transtibial amputation, when compared to the traditional K2 - K3 prosthetic foot on the market? Participants will be asked to do 1. Prior to the commencement of the experiment, a professional prosthetist and orthotist will conduct all fitting and alignment procedures for the transtibial amputees. Participants will then be given a two to three-week period to train and acclimate to the individual socket alignment and prosthetic foot. 2. Participants are asked to refrain from consuming caffeine or any stimulants for 24 hours before the tests. 3. Participants will be required to perform the Berg Balance Test. 4. Participants will undergo a series of clinical tests, including: 1) Time to Go Up (measured in seconds), 2) Four Square Step Test (measured in seconds), 3) 10-Meter Walk Test (measured in seconds), 4) Eye Close Standing, 5) Tandem Test, and 6) Functional Reach Test. Each test will be conducted three times. The test items of 4) and 5) will be performed on a force plate (Bertect, Ohio, USA) with dimensions of 400 x 600 mm and a capturing frequency of 1,000 Hz. 5. Participants will be asked to walk on a force plate (AMTI, Advanced Mechanical Technology, Inc., Watertown, USA) at a fixed walking speed of 1.11 ± 0.11m/s, allowing the foot to land naturally on the force plate. Five trials of the gait cycle with a clean foot will be used for analysis. 6. Participants will perform the Counter Movement Jump Test three times with maximum effort on the force plate (Bertect, Ohio, USA), which will be performed without a hand swing. 7. Participants will be asked to perform a 2-minute walking test on flat concrete ground, stairs, and a ramp, respectively. 8. Finally, participants will be asked to complete the Locomotion Capabilities Index questionnaire.


Description:

Thirty-nine passive-reflective markers of 14 mm in diameter were placed on the participant (Figure 1) according to the landmarks set of the plug-in full body model. An 8-camera motion capturing system (VICON, Nexus 2.0 Inc., Oxford, UK) and 2 force plates (AMTI, Advanced Mechanical Technology, Inc., Watertown, USA) mounted under the walkway were utilized for gait analysis and recorded 100 frames per second simultaneously. All the systems were calibrated before the experiment.


Recruitment information / eligibility

Status Enrolling by invitation
Enrollment 6
Est. completion date June 30, 2024
Est. primary completion date April 30, 2024
Accepts healthy volunteers No
Gender All
Age group 36 Years to 64 Years
Eligibility Inclusion Criteria: - unilateral transtibial amputees, - with more than 12 months of experience using a prosthesis, - with a K2 prosthesis or above, - be able to walk continuously unaided with the prosthetic foot for at least 20 minutes. Exclusion Criteria: - with a short or an injured residual limb, - pregnant, - any neurological or musculoskeletal diseases, - have a record of active endocarditis and acute myocarditis/pericarditis, - experience ongoing unstable angina, - have uncontrolled cardiac arrhythmia with hemodynamic compromise, - have had a recent stroke or transient ischemic attack, - have high blood pressure, etc.

Study Design


Related Conditions & MeSH terms


Intervention

Device:
Prosthetic foot
A low-cost prosthetic foot designed to enhance gait mechanics and physical performance in individuals who have undergone traumatic unilateral transtibial amputation, as compared to the traditional K2 - K3 prosthetic feet currently available on the market, during both indoor and outdoor activities, whilst satisfying the users' satisfaction levels after traumatic unilateral transtibial amputation.

Locations

Country Name City State
Hong Kong The Hong Kong Polytechnic University Kowloon

Sponsors (1)

Lead Sponsor Collaborator
The Hong Kong Polytechnic University

Country where clinical trial is conducted

Hong Kong, 

References & Publications (11)

Arifin N, Abu Osman NA, Ali S, Wan Abas WA. The effects of prosthetic foot type and visual alteration on postural steadiness in below-knee amputees. Biomed Eng Online. 2014 Mar 5;13(1):23. doi: 10.1186/1475-925X-13-23. — View Citation

Batten HR, McPhail SM, Mandrusiak AM, Varghese PN, Kuys SS. Gait speed as an indicator of prosthetic walking potential following lower limb amputation. Prosthet Orthot Int. 2019 Apr;43(2):196-203. doi: 10.1177/0309364618792723. Epub 2018 Aug 16. — View Citation

Berg KO, Wood-Dauphinee SL, Williams JI, Maki B. Measuring balance in the elderly: validation of an instrument. Can J Public Health. 1992 Jul-Aug;83 Suppl 2:S7-11. — View Citation

Dite W, Temple VA. A clinical test of stepping and change of direction to identify multiple falling older adults. Arch Phys Med Rehabil. 2002 Nov;83(11):1566-71. doi: 10.1053/apmr.2002.35469. — View Citation

Franchignoni F, Orlandini D, Ferriero G, Moscato TA. Reliability, validity, and responsiveness of the locomotor capabilities index in adults with lower-limb amputation undergoing prosthetic training. Arch Phys Med Rehabil. 2004 May;85(5):743-8. doi: 10.10 — View Citation

Gremeaux V, Damak S, Troisgros O, Feki A, Laroche D, Perennou D, Benaim C, Casillas JM. Selecting a test for the clinical assessment of balance and walking capacity at the definitive fitting state after unilateral amputation: a comparative study. Prosthet — View Citation

Kent JA, Stergiou N, Wurdeman SR. Dynamic balance changes within three weeks of fitting a new prosthetic foot component. Gait Posture. 2017 Oct;58:23-29. doi: 10.1016/j.gaitpost.2017.07.003. Epub 2017 Jul 5. — View Citation

Pickenbrock HM, Diel A, Zapf A. A comparison between the Static Balance Test and the Berg Balance Scale: validity, reliability, and comparative resource use. Clin Rehabil. 2016 Mar;30(3):288-93. doi: 10.1177/0269215515578297. Epub 2015 Mar 23. — View Citation

Segal AD, Orendurff MS, Klute GK, McDowell ML, Pecoraro JA, Shofer J, Czerniecki JM. Kinematic and kinetic comparisons of transfemoral amputee gait using C-Leg and Mauch SNS prosthetic knees. J Rehabil Res Dev. 2006 Nov-Dec;43(7):857-70. doi: 10.1682/jrrd — View Citation

Shi QQ, Yick KL, Wu J, Huang X, Tse CY, Chan MK. A Scientometric Analysis and Visualization of Prosthetic Foot Research Work: 2000 to 2022. Bioengineering (Basel). 2023 Sep 28;10(10):1138. doi: 10.3390/bioengineering10101138. — View Citation

Shumway-Cook A, Brauer S, Woollacott M. Predicting the probability for falls in community-dwelling older adults using the Timed Up & Go Test. Phys Ther. 2000 Sep;80(9):896-903. — View Citation

* Note: There are 11 references in allClick here to view all references

Outcome

Type Measure Description Time frame Safety issue
Primary Basic mobility function with two prostheses by Berg Balance Test Participants will be invited to visit the laboratory twice to participate in two prostheses will be compared by conducting Berg Balance Test including 14 items, each item is graded using a 5-point ordinal scale. up to 12 weeks
Primary Basic mobility function with two prostheses by Time to Go Up Participants will be invited to visit the laboratory twice to participate in two prostheses will be compared by conducting Time to Go Up (seconds), including stand up from chair, walk 3 meters, turn around and back, then sit. up to 12 weeks
Primary Basic mobility function with two prostheses by Four Square Step Test Participants will be invited to visit the laboratory twice to participate in two prostheses will be compared by conducting Four Square Step Test (seconds). up to 12 weeks
Primary Basic mobility function with two prostheses by 10-meter Walk Test Participants will be invited to visit the laboratory twice to participate in two prostheses will be compared by conducting 10-Meter Walk Test (m/s). up to 12 weeks
Primary Stability index with two prostheses by Eye Close Standing Participants will be invited to the laboratory twice to participate in an experiment. In each session, they will be required to perform the Eye Close Standing on a force plate (Bertect, Ohio, USA). The test will be conducted three times, with each attempt lasting 30 seconds. Participants will perform the task using either a low-cost prosthesis or their own prosthetic foot. The averaged anterior-posterior stability index (mm), and medial-lateral stability index (mm) will be calculated automatically by Noraxon software for each task to assess the ability of maintaining posture stability with two prostheses. up to 12 weeks
Primary Stability index with two prostheses by Tandem Test Participants will be invited to the laboratory twice to participate in an experiment. In each session, they will be required to perform the Tandem Test on a force plate (Bertect, Ohio, USA). The test will be conducted three times, with each attempt lasting 30 seconds. Participants will perform the task using either a low-cost prosthesis or their own prosthetic foot. The averaged anterior-posterior stability index (mm), and medial-lateral stability index (mm) will be calculated automatically by Noraxon software for each task to assess the ability of maintaining posture stability with two prostheses. up to 12 weeks
Primary Functional Reach Test Participants will move from the vertical standing position to the maximum lean forward position, with the feet firmly placed on the floor with either prosthetic foot for three times. The averaged distance (cm) with two prostheses will be compared. up to 12 weeks
Primary Gait symmetry analysis of lower limb joint angle For collecting the kinematic and kinetic data for gait symmetry analysis, thirty-nine passive-reflective markers were placed on the participant according to the landmarks set of the plug-in full body model. An 8-camera motion capturing system (VICON, Nexus 2.0 Inc., Oxford, UK) and 2 force plates (AMTI, Advanced Mechanical Technology, Inc., Watertown, USA) mounted under the walkway were recorded 100 frames per second simultaneously. All the systems were calibrated before the experiment. Participants will be asked to walk on a force plate (AMTI, Advanced Mechanical Technology, Inc., Watertown, USA) at a fixed walking speed of 1.11 ± 0.11m/s, allowing the foot to land naturally on the force plate. Five trials of the gait cycle with a clean foot will be used for analysis. The joint angle (degree) of symmetry index with two prostheses during gait will be compared. up to 12 weeks
Primary Gait symmetry analysis of lower limb joint power For collecting the kinematic and kinetic data for gait symmetry analysis, thirty-nine passive-reflective markers were placed on the participant according to the landmarks set of the plug-in full body model. An 8-camera motion capturing system (VICON, Nexus 2.0 Inc., Oxford, UK) and 2 force plates (AMTI, Advanced Mechanical Technology, Inc., Watertown, USA) mounted under the walkway were recorded 100 frames per second simultaneously. All the systems were calibrated before the experiment. Participants will be asked to walk on a force plate (AMTI, Advanced Mechanical Technology, Inc., Watertown, USA) at a fixed walking speed of 1.11 ± 0.11m/s, allowing the foot to land naturally on the force plate. Five trials of the gait cycle with a clean foot will be used for analysis. The power (W/kg) of symmetry index with two prostheses during gait will be compared. up to 12 weeks
Primary Gait symmetry analysis of lower limb joint moment For collecting the kinematic and kinetic data for gait symmetry analysis, thirty-nine passive-reflective markers were placed on the participant according to the landmarks set of the plug-in full body model. An 8-camera motion capturing system (VICON, Nexus 2.0 Inc., Oxford, UK) and 2 force plates (AMTI, Advanced Mechanical Technology, Inc., Watertown, USA) mounted under the walkway were recorded 100 frames per second simultaneously. All the systems were calibrated before the experiment. Participants will be asked to walk on a force plate (AMTI, Advanced Mechanical Technology, Inc., Watertown, USA) at a fixed walking speed of 1.11 ± 0.11m/s, allowing the foot to land naturally on the force plate. Five trials of the gait cycle with a clean foot will be used for analysis. The moment (Nm/kg) of symmetry index with two prostheses during gait will be compared. up to 12 weeks
Primary Walking feasibility with two prostheses Participants will be invited to visit the campus twice to participate in an experiment. During each visit, they will be asked to walk on flat ground, stairs, and a ramp for two minutes each, using either a low-cost prosthesis or their own prosthetic foot. The distances (meters) covered with the two different prostheses will then be compared. up to 12 weeks
Primary Jump feasibility with two prostheses Participants will be invited to visit the laboratory twice to participate in an experiment. During each visit, they will be asked to perform the countermovement jump on the force plate (Bertect, Ohio, USA) for three times, using either a low-cost prosthesis or their own prosthetic foot. The average of three times jump height, vertical ground reaction force during different jump phases with two different prostheses will be compared. up to 12 weeks
Primary Subjective evaluation by Locomotion Capabilities Index questionnaire participants will be asked to complete the Locomotion Capabilities Index questionnaire including 14 items, each rated with a 5-level scale. up to 12 weeks
See also
  Status Clinical Trial Phase
Recruiting NCT03947450 - Autologous Volar Fibroblast Injection Into the Stump Site of Amputees Phase 2
Completed NCT04924036 - Qbrexza Cloths for Hyperhidrosis of Amputation Sites Phase 2
Recruiting NCT04839497 - Multicenter Trial Evaluating the Safety and Efficacy of Autologous Volar Fibroblast Injection Into the Terminal Limb of Amputees. Phase 2
Recruiting NCT04212299 - Transfemoral Socket Design and Muscle Function N/A
Completed NCT03733054 - Understanding Prosthetic Needs and Outcomes in Women Veterans With Amputation
Completed NCT03651830 - A Test-Drive Strategy for the Prescription of Prosthetic Feet for People With Leg Amputations N/A
Recruiting NCT04725006 - Sensory Responses to Dorsal Root Stimulation N/A
Not yet recruiting NCT06007885 - Examining Capacity Building of Youth With Physical Disabilities to Pursue Participation Following the PREP Intervention. N/A
Not yet recruiting NCT04936789 - Clinical Feasibility of the IMES Transradial Prosthesis N/A
Completed NCT01155024 - Clinical Evaluation of Direct Manufactured Prosthetic Sockets Phase 2
Completed NCT00663663 - Telephone Intervention for Pain Study (TIPS) N/A
Terminated NCT00778856 - Hand Transplantation for the Reconstruction of Below the Elbow Amputations N/A
Recruiting NCT00388752 - Acupuncture for the Treatment of Phantom Limb and Residual Limb Pain After Amputation Phase 1
Active, not recruiting NCT03374319 - Somatotopic Configuration of Distal Residual Limb Tissues in Lower Extremity Amputations N/A
Completed NCT05542901 - Comparison of Joint Position Sense in Diabetic and Traumatic Transtibial Amputees N/A
Completed NCT05161364 - Kinetic Analysis Due to Foot Dysfunction
Recruiting NCT06194838 - Clinical Outcomes With Non-Powered vs. Powered Prosthetic Knees by K2-level Amputees N/A
Completed NCT03570788 - HRQoL Among Patients Amputated Due to Peripheral Arterial Disease
Completed NCT05778799 - Physical Activity and Sports for People With Special Needs
Recruiting NCT04804150 - Daily Socket Comfort in Transtibial Amputee With an Active Vacuum Suspension System N/A