Ametropia Clinical Trial
Official title:
Performance of Toric Hydrogel Lenses Following A Refit With Toric Silicone Hydrogel Lenses for 1 Month
NCT number | NCT03835221 |
Other study ID # | EX-MKTG-96 |
Secondary ID | |
Status | Completed |
Phase | N/A |
First received | |
Last updated | |
Start date | January 1, 2019 |
Est. completion date | July 6, 2019 |
Verified date | May 2020 |
Source | Coopervision, Inc. |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
The aim of this prospective study is to evaluate the clinical performance of habitual wearers of methafilcon A toric lenses after a refit with fanfilcon A toric lenses for 1-month of daily wear.
Status | Completed |
Enrollment | 43 |
Est. completion date | July 6, 2019 |
Est. primary completion date | March 27, 2019 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years to 40 Years |
Eligibility |
Inclusion Criteria: - Is between 18 and 40 years of age (inclusive) - Has had a self-reported visual exam in the last two years - Is an adapted soft contact lens wearer - Has a contact lens spherical prescription between +6.00 to - 8.00 (inclusive)-Have no less than -0.75D of astigmatism and no more than -2.25 D in both eyes - Can achieve best corrected spectacle distance visual acuity of 20/25 (0.10 logMAR) or better in each eye. - Can achieve a distance visual acuity of 20/30 (0.18 logMAR) or better in each eye with the study contact lenses. - Has clear corneas and no active ocular disease - Has read, understood and signed the information consent letter - Patient contact lens refraction should fit within the available parameters of the study lenses - Is willing to comply with the wear schedule (at least 5 days per week, >8 hours/day assuming there are no contraindications for doing so) - Is willing to comply with the visit schedule Exclusion Criteria: - Has a Contact Lens (CL) prescription outside the range of the available parameters of the study lenses - Has a spectacle cylinder less than -0.75D or more than -2.50 D of cylinder in either eye - Has a history of not achieving comfortable Contact Lens (CL) wear (5 days per week; > 8 hours/day) - Has contact lens best corrected distance vision worse than 20/25 (0.10 logMAR) in either eye - Presence of clinically significant (grade 2-4) anterior segment abnormalities - Presence of ocular or systemic disease or need of medications which might interfere with contact lens wear - Slit lamp findings that would contraindicate contact lens wear such as: - Pathological dry eye or associated findings - Pterygium, pinguecula, or corneal scars within the visual axis - Neovascularization > 0.75 mm in from of the limbus - Giant papillary conjunctivitis (GCP) worse than grade 1 - Anterior uveitis or iritis (past or present) - Seborrheic eczema, Seborrheic conjunctivitis - History of corneal ulcers or fungal infections - Poor personal hygiene - Has a known history of corneal hypoesthesia (reduced corneal sensitivity) - Has aphakia, keratoconus or a highly irregular cornea - Has Presbyopia or has dependence on spectacles for near work over the contact lenses - Has undergone corneal refractive surgery - Is participating in any other type of eye related clinical or research study. |
Country | Name | City | State |
---|---|---|---|
Mexico | Optometry Clinic, National Autonomous University | Mexico City |
Lead Sponsor | Collaborator |
---|---|
Coopervision, Inc. |
Mexico,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Number of Participants With Lens Centration Assessment by the Investigator - Methafilcon A Toric Contact Lenses | Lens centration was assessed on a 3-point scale (1=optimal centration, 2=decentration acceptable, 3=decentration unacceptable). | Baseline | |
Primary | Number of Participants With Lens Centration Assessment by the Investigator - Methafilcon A Toric Contact Lenses | Lens centration was assessed on a 3-point scale (1=optimal centration, 2=decentration acceptable, 3=decentration unacceptable). | 4 weeks | |
Primary | Number of Participants With Lens Centration Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Lens centration was assessed on a 3-point scale (1=optimal centration, 2=decentration acceptable, 3=decentration unacceptable). | Baseline | |
Primary | Number of Participants With Lens Centration Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Lens centration was assessed on a 3-point scale (1=optimal centration, 2=decentration acceptable, 3=decentration unacceptable). | 2 weeks | |
Primary | Number of Participants With Lens Centration Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Lens centration was assessed on a 3-point scale (1=optimal centration, 2=decentration acceptable, 3=decentration unacceptable). | 4 weeks | |
Primary | Percentage of Participants With Corneal Coverage Assessment by the Investigator - Methafilcon A Toric Contact Lenses | Corneal coverage was collected on a YES/NO response. Yes - lens covers the cornea, No - lens does not cover the cornea | Baseline | |
Primary | Percentage of Participants With Corneal Coverage Assessment by the Investigator - Methafilcon A Toric Contact Lenses | Corneal coverage was collected on a YES/NO response. Yes - lens covers the cornea, No - lens does not cover the cornea | 4 weeks | |
Primary | Percentage of Participants With Corneal Coverage Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Corneal coverage was collected on a YES/NO response. Yes - lens covers the cornea, No - lens does not cover the cornea | Baseline | |
Primary | Percentage of Participants With Corneal Coverage Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Corneal coverage was collected on a YES/NO response. Yes - lens covers the cornea, No - lens does not cover the cornea | 2 weeks | |
Primary | Percentage of Participants With Corneal Coverage Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Corneal coverage was collected on a YES/NO response. Yes - lens covers the cornea, No - lens does not cover the cornea | 4 weeks | |
Primary | Post-blink Movement Assessment by the Investigator - Methafilcon A Toric Contact Lenses | Post-blink movement was assessed on a 0-4 scale (where: 0=Insufficient, unacceptable movement,1=Minimal, but acceptable movement, 2=Optimal movement, 3=Moderate, but acceptable movement, 4=Excessive, unacceptable movement). | Baseline | |
Primary | Post-blink Movement Assessment by the Investigator - Methafilcon A Toric Contact Lenses | Post-blink movement was assessed on a 0-4 scale (where: 0=Insufficient, unacceptable movement,1=Minimal, but acceptable movement, 2=Optimal movement, 3=Moderate, but acceptable movement, 4=Excessive, unacceptable movement). | 4 weeks | |
Primary | Post-blink Movement Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Post-blink movement was assessed on a 0-4 scale (where: 0=Insufficient, unacceptable movement,1=Minimal, but acceptable movement, 2=Optimal movement, 3=Moderate, but acceptable movement, 4=Excessive, unacceptable movement). | Baseline | |
Primary | Post-blink Movement Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Post-blink movement was assessed on a 0-4 scale (where: 0=Insufficient, unacceptable movement,1=Minimal, but acceptable movement, 2=Optimal movement, 3=Moderate, but acceptable movement, 4=Excessive, unacceptable movement). | 2 weeks | |
Primary | Post-blink Movement Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Post-blink movement was assessed on a 0-4 scale (where: 0=Insufficient, unacceptable movement,1=Minimal, but acceptable movement, 2=Optimal movement, 3=Moderate, but acceptable movement, 4=Excessive, unacceptable movement). | 4 weeks | |
Primary | Lens Orientation in Primary Position of Gaze Assessment by the Investigator - Methalfilcon A Toric Contact Lenses | Lens orientation was assessed in 5-degree steps with the slit lamp by measuring the amount of mislocation of the axis mark on the lens relative to the 6 o'clock position. | Baseline | |
Primary | Lens Orientation in Primary Position of Gaze Assessment by the Investigator - Methalfilcon A Toric Contact Lenses | Lens orientation was assessed in 5-degree steps with the slit lamp by measuring the amount of mislocation of the axis mark on the lens relative to the 6 o'clock position. | 4 weeks | |
Primary | Lens Orientation in Primary Position of Gaze Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Lens orientation was assessed in 5-degree steps with the slit lamp by measuring the amount of mislocation of the axis mark on the lens relative to the 6 o'clock position. | Baseline | |
Primary | Lens Orientation in Primary Position of Gaze Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Lens orientation was assessed in 5-degree steps with the slit lamp by measuring the amount of mislocation of the axis mark on the lens relative to the 6 o'clock position. | 2 weeks | |
Primary | Lens Orientation in Primary Position of Gaze Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Lens orientation was assessed in 5-degree steps with the slit lamp by measuring the amount of mislocation of the axis mark on the lens relative to the 6 o'clock position. | 4 weeks | |
Primary | Rotational Recovery Assessment by the Investigator - Methafilcon A Toric Contact Lenses | Lens rotational recovery was assessed in 5-degree steps 1 minute after the lens was manually rotated 45degrees temporally from the primary gaze position | Baseline | |
Primary | Rotational Recovery Assessment by the Investigator - Methafilcon A Toric Contact Lenses | Lens rotational recovery was assessed in 5-degree steps 1 minute after the lens was manually rotated 45degrees temporally from the primary gaze position | 4 weeks | |
Primary | Rotational Recovery Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Lens rotational recovery was assessed in 5-degree steps 1 minute after the lens was manually rotated 45degrees temporally from the primary gaze position | Baseline | |
Primary | Rotational Recovery Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Lens rotational recovery was assessed in 5-degree steps 1 minute after the lens was manually rotated 45degrees temporally from the primary gaze position | 2 weeks | |
Primary | Rotational Recovery Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Lens rotational recovery was assessed in 5-degree steps 1 minute after the lens was manually rotated 45degrees temporally from the primary gaze position | 4 weeks | |
Primary | Overall Stability Assessment by the Investigator - Methafilcon A Toric Contact Lenses | Overall lens stability was assessed using a 0 - 4 scale (where 0 = very poor stability, and 4 = excellent stability). | Baseline | |
Primary | Overall Stability Assessment by the Investigator - Methafilcon A Toric Contact Lenses | Overall lens stability was assessed using a 0 - 4 scale (where 0 = very poor stability, and 4 = excellent stability). | 4 weeks | |
Primary | Overall Stability Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Overall lens stability was assessed using a 0 - 4 scale (where 0 = very poor stability, and 4 = excellent stability). | Baseline | |
Primary | Overall Stability Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Overall lens stability was assessed using a 0 - 4 scale (where 0 = very poor stability, and 4 = excellent stability). | 2 weeks | |
Primary | Overall Stability Assessment by the Investigator - Fanfilcon A Toric Contact Lenses | Overall lens stability was assessed using a 0 - 4 scale (where 0 = very poor stability, and 4 = excellent stability). | 4 weeks | |
Primary | Overall Lens Fit Acceptance by the Investigator - Methafilcon A Toric Contact Lenses | Overall lens fit acceptance assessed using grade (0-4) 0=Should not be worn, 1=Borderline but unacceptable, 2=Minimal acceptable, early review, 3=Not perfect but okay to dispense, 4=perfect. | Baseline | |
Primary | Overall Lens Fit Acceptance by the Investigator - Methafilcon A Toric Contact Lenses | Overall lens fit acceptance assessed using grade (0-4) 0=Should not be worn, 1=Borderline but unacceptable, 2=Minimal acceptable, early review, 3=Not perfect but okay to dispense, 4=perfect. | 4 weeks | |
Primary | Overall Lens Fit Acceptance by the Investigator - Fanfilcon A Toric Contact Lenses | Overall lens fit acceptance assessed using grade (0-4) 0=Should not be worn, 1=Borderline but unacceptable, 2=Minimal acceptable, early review, 3=Not perfect but okay to dispense, 4=perfect. | Baseline | |
Primary | Overall Lens Fit Acceptance by the Investigator - Fanfilcon A Toric Contact Lenses | Overall lens fit acceptance assessed using grade (0-4) 0=Should not be worn, 1=Borderline but unacceptable, 2=Minimal acceptable, early review, 3=Not perfect but okay to dispense, 4=perfect. | 2 weeks | |
Primary | Overall Lens Fit Acceptance by the Investigator - Fanfilcon A Toric Contact Lenses | Overall lens fit acceptance assessed using grade (0-4) 0=Should not be worn, 1=Borderline but unacceptable, 2=Minimal acceptable, early review, 3=Not perfect but okay to dispense, 4=perfect. | 4 weeks | |
Secondary | Average Daily Wearing Time - Methafilcon A Toric Contact Lenses | Average daily wearing time response by the subject | 4 weeks | |
Secondary | Average Daily Wearing Time - Fanfilcon A Toric Contact Lenses | Average daily wearing time response by the subject | 2 weeks | |
Secondary | Average Daily Wearing Time - Fanfilcon A Toric Contact Lenses | Average daily wearing time response by the subject | 4 weeks | |
Secondary | Average Comfortable Wearing Time - Methafilcon A Toric Contact Lenses | Average comfortable wearing time - response by the subject | 4 weeks | |
Secondary | Average Comfortable Wearing Time - Fanfilcon A Toric Contact Lenses | Average comfortable wearing time - response by the subject | 2 weeks | |
Secondary | Average Comfortable Wearing Time - Fanfilcon A Toric Contact Lenses | Average comfortable wearing time - response by the subject | 4 weeks |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04532099 -
Clinical Comparison of Two Daily Wear Frequent Replacement Silicone Hydrogel Soft Contact Lenses
|
N/A | |
Completed |
NCT03319212 -
Clinical Characterization of Symptomatic Populations
|
N/A | |
Withdrawn |
NCT04525170 -
Clinical Evaluation of HPT Treated Rigid Contact Lenses Made From Hexafocon A
|
N/A | |
Completed |
NCT05483127 -
Clinical Comparison of Two Daily Disposable Toric Soft Contact Lenses
|
N/A | |
Completed |
NCT01741987 -
Osmoprotective Containing Lubricants in Dysfunctional Tear Syndrome and Post Refractive Surgery Patients
|
N/A | |
Completed |
NCT03688672 -
Apioc Contact Lens Feasibility
|
N/A | |
Completed |
NCT02312323 -
One-month Clinical Evaluation of Silicone Hydrogel Definitive 65 HPT Contact Lenses
|
N/A | |
Recruiting |
NCT04714424 -
Comparing Vision Tests in a Virtual Reality Headset to Existing Analogues
|
||
Recruiting |
NCT04632784 -
Clinical Trial With Artiflex Presbyopic
|
N/A | |
Completed |
NCT04185701 -
Comparison of Subjective Refraction Measurement With SiVIEW Software and by an Expert
|
N/A | |
Completed |
NCT01706770 -
Evaluation of Enfilcon A Soft Contact Lens When Compared to Galyfilcon A Soft Contact Lens
|
N/A | |
Completed |
NCT03556579 -
The Effects of Contact Lenses With Experimental Dye on Visual Function
|
N/A | |
Completed |
NCT04654455 -
Prospective Study Evaluating Dry Eye in Patients Operated on for Ametropia by LASIK Surgery and Treated With REPADROP
|
||
Not yet recruiting |
NCT06295536 -
Optimization of a Photoretinoscopy Method for Determining the Objective Refraction of Children
|
N/A | |
Completed |
NCT00691197 -
Safety and Acceptability of Using a Rewetting Drop With Contact Lens Wear
|
Phase 2/Phase 3 | |
Completed |
NCT00597467 -
Study of Soft Contact Lens Use With 7 Day Extended Wear
|
N/A | |
Completed |
NCT04067141 -
The Clinical Comparison of Somofilcon A 1 Day and Nelfilcon A Daily Disposable Contact Lenses
|
N/A | |
Completed |
NCT04067050 -
A Clinical Study of the Comfilcon A Asphere Soft Contact Lens in Users of Digital Devices
|
N/A | |
Completed |
NCT02553681 -
Clinical Evaluation of HPT Treated Rigid Contact Lenses Made From Roflufocon D
|
N/A | |
Completed |
NCT00722891 -
Ocular Responses to Short and Long-term Lens Wear
|
N/A |