This clinical trial will document the feasibility of the Apioc lens design by assessing which lens shape parameters yield successful on-eye-fit and movement of the Apioc contact lens design and evaluate the subjectively-reported comfort of the Apioc contact lens design.


Clinical Trial Description

This is a one-site, non-dispensing clinical trial using the Apioc contact lens design. This soft contact lens study will determine the feasibility of this design by determining which parameters of the shape of the Apioc Contact Lens design will yield a successful fit across subjects. We will also determine the percentage of subjects who can be successfully fitted with the Apioc Contact Lens Design. Because the feasibility of the lens design may be dependent upon age, a total of 50 subjects (10 subjects each across 5 decades of life) will complete the study. The data will be collected in a single visit for most subjects. A few subjects may be asked to return for a second visit if additional contact lens parameters need to be ordered to achieve a successful fit. The key assessments for this study will be demonstration of feasibility of fit, documentation of movement in all gazes, including translation, and subjective reports of comfort. Subjects will only wear contact lenses while in the office. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03688672
Study type Interventional
Source Lentechs, LLC
Contact
Status Completed
Phase N/A
Start date October 1, 2018
Completion date October 31, 2020

See also
  Status Clinical Trial Phase
Recruiting NCT04923841 - Myopia Control Using Bright Light Therapy, Myopic Defocus and Atropine N/A
Active, not recruiting NCT04080128 - Examination of Myopia Progression and Soft Bifocal Contact Lens Myopia Control N/A
Active, not recruiting NCT05275959 - Beijing (Peking)---Myopia and Obesity Comorbidity Intervention (BMOCI) N/A
Completed NCT04604405 - Effects of 650nm Low Energy Light on Human Retina and Choroid Microcirculation N/A
Recruiting NCT05594719 - The Effect of Sun-like Spectrum With Different Spectrum Composition on Retinal Blood Flow N/A
Completed NCT05594732 - The Effects of Different Outdoor Light Exposure Modes on Retinal Blood Flow N/A
Completed NCT04492397 - Comparing The Performance Of Two Different Daily Disposable Lenses (MIKI) N/A
Completed NCT04536571 - Vision Stability and Preference for Soft Toric vs. Soft Spherical Contact Lenses N/A
Completed NCT06046209 - Comparing a Monthly Replacement Lens Versus a Daily Disposable Lens N/A
Recruiting NCT06344572 - Pivotal Study of SAT-001 in Treatment of Pediatric Patient With Myopia Phase 3
Recruiting NCT05611294 - Contralateral Study of Topography Guided LASIK Versus Small Incision Lenticule Extraction N/A
Completed NCT05656885 - Clinical Evaluation of Two Frequent Replacement Soft Spherical Contact Lenses N/A
Active, not recruiting NCT05534022 - Clinical Evaluation of a Myopia Control Lens in Slowing Myopia Progression. N/A
Completed NCT03934788 - the Clinical Performance of the Oxysoft Daily Disposable Silicone Hydrogel Soft Contact Lens N/A
Completed NCT03701516 - Clinical Evaluation of Etafilcon A Contact Lenses Using a Novel Molding Process 2 N/A
Completed NCT05538754 - Post-Market Evaluation of the EVO ICL N/A
Completed NCT03139201 - Clinical Performance of the OxyAqua Daily Disposable Silicone Hydrogel Soft Contact Lens N/A
Completed NCT02555722 - Evaluation of the CooperVision, Inc. Fanfilcon A and Enfilcon A Daily Wear Contact Lenses When Used for Frequent Replacement for up to One (1) Month of Daily Wear N/A
Not yet recruiting NCT06009458 - Acuity 200™ (Fluoroxyfocon A) Orthokeratology Contact Lens for Overnight Wear N/A
Recruiting NCT05548478 - Corneal Endothelial Cell Injury Induced by Mitomycin-C N/A