Alveolar Ridge Preservation Clinical Trial
Official title:
Novel Porous Bioceramic Material as a Bone Substitute. Clinical Trial.
Verified date | October 2023 |
Source | Orton Orthopaedic Hospital |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
The aim of this study is to demonstrate that new synthetic bone graft bioceramic composites (Adaptos®-Si and Adaptos®, Biomendex Oy) are able to support the preservation of the alveolar ridge and to promote bone regeneration following dental extraction. New bone graft substitutes are compared with already existing treatment principles used following dental extraction. The primary hypothesis of the study is that Adaptos®-Si granules can reach a clinical outcome superior to that of dental socket left empty after extraction. Secondary aim is that new bioceramic composites can reach a clinical outcome non inferior to the active comparator of this study (Geistlisch Bio-Oss®).
Status | Terminated |
Enrollment | 76 |
Est. completion date | January 27, 2023 |
Est. primary completion date | January 27, 2023 |
Accepts healthy volunteers | No |
Gender | All |
Age group | 18 Years to 80 Years |
Eligibility | Inclusion Criteria: - Patient must have voluntarily signed the informed consent - Females and males, 18 years to 80 years of age - Patient needs single tooth extraction of 1st or 2nd premolar or molar tooth - At least one adjacent teeth present - At least 3 intact walls - Subjects must be committed to the study and the required follow-up visits Exclusion Criteria: - Planned radiation or radiation during previous year in the tooth extraction area. - Smoking - Osteoporosis - Uncontrolled periodontitis - Alcohol or drug abuse - Pregnant or breastfeeding women - Uncontrolled diabetes - Local acute or chronic infection or presence of oral lesions or trauma - Immunosuppressive disease, treatment, or medication - Subject is part of the investigator team of this study or investigator's family member - Subject is employee of one of the organizations involve in this study |
Country | Name | City | State |
---|---|---|---|
Finland | Oral Hammaslääkärit Oyj, Qmedical Pikku Huopalahti | Helsinki |
Lead Sponsor | Collaborator |
---|---|
Orton Orthopaedic Hospital | Biomendex Oy, Oral Hammaslääkärit Oy, Qmedical Pikku Huopalahti, Tampere University |
Finland,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Other | Comparison between radiological assessment methods | The ridge width and height are measured from 2D images of CBCT scans (in mm) and change in dimensions in time is determined using these measurements. Reduction is also measured directly on the superimposed baseline and follow-up CBCT scans (in mm).The vertical reference line is outlined from the apex through the center of the socket and the horizontal reference line through the apex perpendicular to the vertical line. The ridge width (in mm) is measured parallel to the horizontal reference line 1 mm, 3 mm, and 5 mm from the highest buccal ridge point on baseline. Ridge heights (in mm) are measured from the most apical point of the alveolar socket parallel to the vertical reference line. | baseline, 5 months, and 10 months post-extraction | |
Primary | Alveolar ridge preservation, comparison between Adaptos-Si filled extraction sockets and empty sockets. | Alveolar ridge horizontal and vertical change assessment by cone-beam computed tomography (CBCT). The vertical reference line is outlined from the apex through the center of the socket and the horizontal reference line through the apex perpendicular to the vertical line. The ridge width (in mm) is measured parallel to the horizontal reference line 1 mm, 3 mm, and 5 mm from the highest buccal ridge point on baseline. Ridge heights (in mm) are measured from the most apical point of the alveolar socket parallel to the vertical reference line. The dimensional changes of the ridge assessed on CBCT images immediately post-extraction, are acquired five months and ten months later. Comparison between Adaptos-Si filled extraction sockets and empty sockets. | baseline, 5 months, and 10 months post-extraction | |
Secondary | Alveolar ridge horizontal and vertical change (in mm) assessment by CBCT, comparisons between extraction sockets filled with Adaptos-Si or Bio-Oss bone graft substitutes. | Alveolar ridge horizontal and vertical change assessment by cone-beam computed tomography (CBCT). The vertical reference line is outlined from the apex through the center of the socket and the horizontal reference line through the apex perpendicular to the vertical line. The ridge width (in mm) is measured parallel to the horizontal reference line 1 mm, 3 mm, and 5 mm from the highest buccal ridge point on baseline. Ridge heights (in mm) are measured from the most apical point of the alveolar socket parallel to the vertical reference line. The dimensional changes of the ridge assessed on CBCT images immediately post-extraction, are acquired five months and ten months later. Comparison between extraction sockets filled with Adaptos-Si or Bio-Oss bone graft substitutes. | baseline, 5 months, and 10 months post-extraction | |
Secondary | Alveolar ridge horizontal and vertical change (in mm) assessment by CBCT, comparison between Adaptos filled extraction sockets and empty sockets. | Alveolar ridge horizontal and vertical change assessment by cone-beam computed tomography (CBCT). The vertical reference line is outlined from the apex through the center of the socket and the horizontal reference line through the apex perpendicular to the vertical line. The ridge width (in mm) is measured parallel to the horizontal reference line 1 mm, 3 mm, and 5 mm from the highest buccal ridge point on baseline. Ridge heights (in mm) are measured from the most apical point of the alveolar socket parallel to the vertical reference line. The dimensional changes of the ridge assessed on CBCT images immediately post-extraction, are acquired five months and ten months later. Comparison between Adaptos filled extraction sockets and empty sockets. | baseline, 5 months, and 10 months post-extraction | |
Secondary | Alveolar ridge horizontal and vertical change (in mm) assessment by CBCT, comparison between extraction sockets filled with Adaptos-Si or Adaptos bone graft substitutes. | Alveolar ridge horizontal and vertical change assessment by cone-beam computed tomography (CBCT). The vertical reference line is outlined from the apex through the center of the socket and the horizontal reference line through the apex perpendicular to the vertical line. The ridge width (in mm) is measured parallel to the horizontal reference line 1 mm, 3 mm, and 5 mm from the highest buccal ridge point on baseline. Ridge heights (in mm) are measured from the most apical point of the alveolar socket parallel to the vertical reference line. The dimensional changes of the ridge assessed on CBCT images immediately post-extraction, are acquired five months and ten months later. Comparison between extraction sockets filled with Adaptos-Si or Adaptos bone graft substitutes. | baseline, 5 months, and 10 months post-extraction |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT05517798 -
Enamel Matrix Derivative for Alveolar Ridge Preservation After Tooth Extraction
|
N/A | |
Not yet recruiting |
NCT05553548 -
Alveolar Ridge Changes With Biologically Oriented Alveolar Ridge Preservation (BARP) After Tooth Extraction
|
N/A | |
Active, not recruiting |
NCT03374813 -
Efficacy of MimetikOss in Alveolar Ridge Preservation Previous to Implant Placement
|
N/A | |
Recruiting |
NCT06308536 -
Application of Concentrated Growth Factors in Alveolar Ridge Preservation
|
N/A | |
Active, not recruiting |
NCT05683509 -
Alveolar Ridge Preservation With Layered Collagen and Xenograft
|
N/A | |
Completed |
NCT02707536 -
Influence of Platelet-Rich Fibrin on Post-extraction Alveolar Ridge Healing/Preservation as a Stand-alone or Adjunct to Particulate Graft
|
N/A | |
Completed |
NCT03468998 -
The Influence of Bone Allograft Particle Sizes on the Quantity and Quality of New Bone Formation in Grafted Extraction Sockets and Edentulous Ridges
|
N/A | |
Completed |
NCT03487718 -
A 14 Weeks Longitudinal Study to Investigate the Effect of Leukocyte- Platelet Rich Fibrin Plug on the Quality of the Newly Formed Bone in Ridge Preservation Procedure Following a Tooth Extraction. It is a Clinical, Radiographic and Histomorphometric Study.
|
N/A | |
Not yet recruiting |
NCT06141239 -
2D/3D Imaging to Analyze the Regeneration Rate of Autologous Bone
|
N/A | |
Not yet recruiting |
NCT06435754 -
Hard and Soft Tissue Changes Following Vestibular Socket Preservation Versus Ice Cream Cone Technique for Management of Defective Fresh Extraction Sockets in the Esthetic Zone: A Randomized Clinical Trial
|
N/A | |
Completed |
NCT04321109 -
Alveolar Ridge Preservation Using Collagen Material and Allograft
|
N/A | |
Completed |
NCT03043885 -
Ridge Preservation With Platelet Rich Fibrin Augmented With Freeze Dried Bone Allograft
|
N/A | |
Recruiting |
NCT06275789 -
Mix of Demineralized Freeze-Dried Bone Allograft and Deproteinized Bovine Bone Mineral: a Possible Solution for Alveolar Ridge Preservation?
|
N/A | |
Recruiting |
NCT04296682 -
Impact Of Soft Tissue Manipulation On Dimensional Changes After Posterior Region Extraction.
|
N/A | |
Recruiting |
NCT05601531 -
Autologous Tooth Root in Ridge Preservation
|
N/A | |
Completed |
NCT03422458 -
The Impact of Immediate Implant Placement on Alveolar Ridge Preservation Techniques
|
N/A | |
Completed |
NCT05419778 -
Alveolar Ridge Preservation Procedures
|
||
Completed |
NCT03447795 -
Alveolar Ridge Preservation Using Autogenous Tooth Graft Versus Autogenous Demineralized Dentin Graft.
|
N/A | |
Completed |
NCT05107141 -
Ridge Preservation in Molar Sites Comparing Xenograft Versus Mineralized Freeze-dried Bone Allograft
|
N/A | |
Active, not recruiting |
NCT04824235 -
Alveolar Ridge Preservation Using Amniotic Chorion Membrane
|
N/A |