Airway Obstruction Clinical Trial
Official title:
One Minute Heart Rate Variability Quantification in Airway Obstruction Model
40 healthy volunteers underwent a trial of obstructed breathing through an eighteen cm long, four mm internal diameter tube. Heart rate was recorded during three consecutive sets comprised of one minute control followed by one minute of obstructed breathing, with one minute of rest between sets. Time and frequency domain analysis were used to compare HRV during control versus obstructed breathing.
Following approval by the Institutional Review Board, the study was performed in a
prospective cross-over, longitudinal cohort manner. Healthy volunteers aged between 20 and 40
years were included. Each participant signed an informed consent. Exclusion criteria were
respiratory or cardiac pathology, diabetes, a body mass index lower than 18 or higher than 26
kg/m2, chronic medical conditions with significant involvement of the sympathetic or
parasympathetic systems (e.g. diabetes), obstructive sleep apnea, use of medications with
either cardiovascular or respiratory effects, and ECG abnormalities including heart rate
other than sinus rhythm, atrioventricular conduction blocks, intrafascicular conduction
delays or prolonged QT interval (the time between consecutive Q and T waves on the
electrocardiogram).
Initially, each volunteer underwent an ultrasound evaluation (SonoSite™ M-Turbo™ ultrasound
machine, SonoSite, Bothell, Washington, USA) of the lungs using a high frequency linear probe
at mid clavicular lines to exclude pneumothorax, an apical view of the heart using a
curve-linear probe to exclude pericardial effusion. A twelve lead ECG was obtained and
analyzed to exclude rate or conduction abnormalities. Noninvasive blood pressure and oxygen
saturation were recorded in all subjects throughout the study to identify and prevent any
complication.
A three lead ECG and spirometry were obtained in supine position with the upper body raised
by 30 degrees. Data was collected using a Datex AS/3 monitor (Datex Ohmeda Medical Equipment,
GE Healthcare, USA). The data was recorded using a digital to analog acquisition card
(NI-6008, National Instruments™, Austin, Texas, USA) and a Biosignal Logger of National
Instruments™ Biomedical Workbench™ at a sampling rate of 500 Hertz (Hz). All experiments were
performed at the same time of day (early afternoon), and under the same conditions (same
place and experimental setup). Volunteers were instructed to refrain from smoking for 4 hours
prior to participating in the study.
The airway obstruction was simulated by an 18 cm long, 4 mm internal diameter endotracheal
tube, connected to a spirometry adaptor and an antimicrobial filter. During the obstructed
breathing phase, the volunteers were directed to seal their lips tightly around the filter to
prevent air leak and encouraged to reach a peak pressure of 30-40 cm H2O, using the
instantaneous display on the spirometry monitor. Three sets were recorded for each volunteer;
each set was comprised of one minute of normal unobstructed breathing that served as control,
immediately followed by one minute of obstructed breathing. Following each set, the
volunteers were allowed at least one minute of rest period to recover and return to their
baseline breathing before the next set.
HRV analysis A detailed description of the means to measure and evaluate the significance of
HRV can be found in the European Society of Cardiology and the North American Society of
Pacing Electrophysiology Task Force on heart rate variability, standards of measurement and
physiological interpretation and clinical use guidelines14. Briefly, the raw ECG signal was
preprocessed (including high pass filtering to remove Baseline wandering and ECG feature
identification) and the R-R intervals were extracted from the raw ECG signal using ECG
Features Extractor of National Instruments™ Biomedical Workbench™ with threshold adjust
factor of 0.1, a rough highest heart rate of 60 beats per minute, QRS frequency of 10-25 Hz
and middle QRS onset and offset.
Evaluation of HRV is predominantly performed using time and frequency domains. It may be also
performed using nonlinear methods; however, here the investigators concentrated on the more
commonly used time and frequency domain methods. Time domain measures are based on the
statistical analysis of the time interval between two adjacent QRS waves on the
electrocardiogram complexes, referred to as R-R intervals (time between two consecutive R
waves on the electrocardiogram). R-R intervals standard deviation (SD), root mean square of
successive differences (RMSSD) between adjacent R-R intervals, number of pairs of successive
R-R intervals that differ by more than 50 millisecond (NN50) and proportion of NN50 divided
by total number of R-R intervals (pNN50) are routinely used to quantify HRV. Frequency domain
employ mathematical manipulation to the signal, such as the fast Fourier transform (FFT),
which converts the time function into a sum of sine waves of different frequencies. These are
used to calculate the power spectral density in very low (VLF), low (LF) and high frequency
(HF) ranges and provide a quantification of the physiological HRV-related effects. In this
report the investigators did not include the VLF, as this value cannot be reliably measured
with a brief measurement window of one minute. As HRV is clearly related to the heart rate,
the investigators normalized the HF power and LF power to the heart rate15. The normalized
values are referred to as HFnorm and LFnorm.
HRV parameters were calculated over one minute sampling window using the Heart Rate
Variability Analyzer of National Instruments™ Biomedical Workbench™. Fast Fourier analysis
was employed using a Hanning Window of 1024 samples with a 50% overlap, and with a 2 Hz
interpolation rate and 1024 frequency bins. As suggested in the literature for the power
spectral density calculation, HF was defined as 0.15-0.4 Hz, LF as 0.04-0.15 Hz and VLF as
below 0.04 Hz14.
Respiratory rate calculation To evaluate the changes in respiration during the obstructed
breathing the investigators calculated the respiratory rate during the control and obstructed
breathing periods. the investigators used the raw ECG traces to calculate the respiratory
rate16. This was done primarily based on the R wave amplitude, and calculating the number of
local peaks in the sampling window. To obtain meaningful results the investigators chose the
control and the obstructed breathing segments with the most obvious changes in the R wave
amplitude. Using this methodology the investigators could reliably evaluate the respiratory
rate in 33 subjects.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Enrolling by invitation |
NCT04506346 -
Risk Prediction of Difficult Tracheal Intubation in OSAHS Patient
|
||
Completed |
NCT02106143 -
RejuvenAir™ System Lobectomy Safety and Histology Study
|
N/A | |
Completed |
NCT03274791 -
Clinical Features and Airways Inflammation in Never Smokers and Smokers With COPD
|
N/A | |
Completed |
NCT01721486 -
Acetaminophen's Efficacy For Post-operative Pain
|
Phase 4 | |
Completed |
NCT01765530 -
Efficacy Study of a Novel Device to Clean the Endotracheal Tube
|
N/A | |
Completed |
NCT03656315 -
Scoring System to Predict Depth of Cricothyroid Membrane
|
N/A | |
Recruiting |
NCT05880836 -
In Line Aerosol Nebulization With High Flow
|
N/A | |
Recruiting |
NCT05573919 -
VivAer: A Correlation Between Symptom Scores and Objective Findings
|
N/A | |
Completed |
NCT02403934 -
Jaw Elevation Device in Deep Sedation Study
|
N/A | |
Recruiting |
NCT00452062 -
Dexamethasone and the Prevention of Post-Extubation Airway Obstruction in Adults
|
Phase 2 | |
Completed |
NCT02563210 -
Airway Resistance Measurement in Children 3 to 6 Years of Age
|
N/A | |
Completed |
NCT03488849 -
SureCRIC Standardized Patient Study
|
||
Completed |
NCT03752593 -
The Incidence of Difficult Intubation in Obese Versus Non-obese Patients
|
||
Recruiting |
NCT05974488 -
The Efficacy of Distal Pharyngeal Airway for Oxygenation During TEE
|
N/A | |
Not yet recruiting |
NCT02975791 -
Ultrasonography Versus Palpation for Identification of the Cricothyroid Membrane
|
N/A | |
Completed |
NCT00788788 -
Heliox in Experimental Upper Airway Obstruction
|
Phase 1/Phase 2 | |
Not yet recruiting |
NCT06128811 -
Dental Isolation Systems Among Pediatric Patients With Different Airway Patency
|
N/A | |
Completed |
NCT05550220 -
A Modified Cuff Leak Test and Reintubation in Mechanically Ventilated Patients
|
N/A | |
Completed |
NCT03165461 -
Evaluation of the Use of Tracheal Intubation Through a Laryngeal Tube to Intubate Anesthetized Patients
|
||
Recruiting |
NCT03969147 -
Investigation of a Novel Oropharyngeal Airway: The ManMaxAirway
|
N/A |