Intubation Complication Clinical Trial
Official title:
Comparison of Placement of Double-lumen Endobronchial Tube Using GlideScope With 2 Different Stylet Configurations vs Standard Macintosh Laryngoscopy
The purpose of this study is to compare three different standard of care methods of double-lumen endobronchial tube (DLT) placement in patients who are scheduled to have thoracic surgery in which lung isolation is required.
The purpose of this study is to compare three different standard of care methods of double-lumen endobronchial tube (DLT) placement in patients who are scheduled to have thoracic surgery in which lung isolation is required. The investigators want to evaluate the technique of placement of the double-lumen endobronchial tube (DLT) using an included stylet that has been radically bent (ZU-bend) as compared to a commercial GlideRite stylet with the GlideScope and direct laryngoscopy using the Macintosh laryngoscope. A double-lumen endobronchial tube (DLT) is a breathing tube utilized to manage the airway when lung separation is needed for a surgical procedure. The investigator wants to evaluate how long it takes for successful placement of the double-lumen endobronchial tube (DLT) and assess the difficulty of the procedure experienced by the physician performing the intubation. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Active, not recruiting |
NCT05717907 -
Suction Catheter as a Guide for Nasotracheal Intubation Under General Anesthesia
|
N/A | |
Completed |
NCT03653910 -
Effect-site Concentration of Remifentanil for Double-lumen Tubes Intubation: Airtraq VS Macintosh Laryngoscope
|
N/A | |
Recruiting |
NCT04190524 -
Sonographic Assessment of Cricoid Pressure
|
N/A | |
Completed |
NCT02359370 -
The Effects of Lidocaine and Magnesium Sulphate on the Attenuation of the Hemodynamic Response to Tracheal Intubation
|
Phase 4 | |
Not yet recruiting |
NCT05036460 -
Real-time Sonography in Detecting Inadvertent Esophageal Intubation Among Difficult Intubation Patients
|
N/A | |
Completed |
NCT05502120 -
A Comparison of Vie-Scope and Macintosh Blade Laryngoscopes in Morbidly Obese.
|
N/A | |
Completed |
NCT03992950 -
Effectiveness of Cricoid and Paratracheal Pressures for Occluding Esophagus
|
N/A | |
Completed |
NCT05303948 -
Evaluation of Two Positions for Free Floating Tracheal Intubation in Weightlessness
|
N/A | |
Completed |
NCT03720093 -
Exploratory Analysis of Pulmonary Microbiome in Intubated Patients
|
||
Recruiting |
NCT03031808 -
Comparison of Two Induction Regimens Using Topical Lidocaine or Muscle Relaxant on Sore Throat and Hemodynamics
|
Phase 4 | |
Not yet recruiting |
NCT02918526 -
Hemodynamic Study With PRAM of the Cardiovascular Response to the Positioning of the Extraglottic Device
|
N/A | |
Completed |
NCT02364622 -
The Effects of Flexible Intubating Stylet in the Accurate Placement of Double-lumen Endobronchial Tube
|
N/A | |
Completed |
NCT05249738 -
Tongue Edema Caused by Intubation Tube in Intensive Care Unit Patients
|
||
Completed |
NCT03842306 -
End-tidal Oxygen Can Reliably Predict the Arterial Partial Pressure of Oxygen Among Emergency Department Patients
|
||
Terminated |
NCT03340207 -
Novel Airway Device to Aid Endotracheal Intubations
|
N/A | |
Recruiting |
NCT05782517 -
I-gel vs. Endotracheal Intubation for Laparoscopic Gynaecological Procedures
|
N/A | |
Recruiting |
NCT06085326 -
Smart Checklist Implementation for Pediatric Tracheal Intubations in the ICU- Multicenter Study
|
N/A | |
Active, not recruiting |
NCT06108271 -
Innovative Endotracheal Tube Design Reduces Postoperative Laryngeal Injury
|
N/A | |
Completed |
NCT05668299 -
Determining the Appropriate Setting of an Automated Secretion Removal Technology (TrachFlush)
|
N/A | |
Completed |
NCT04079387 -
Effect of Endotracheal Tube Plus STYLET Versus Endotracheal Tube Alone
|
N/A |