Clinical Trials Logo

Clinical Trial Summary

The objective of this study is to compare tracheal intubation first attempt success rate with the C-MAC indirect videolaryngoscope (Karl Storz, Germany) using a Miller-Blade nr 0 or nr 1 compared to a standard direct laryngoscope with standard blades Miller nr 0 and Miller nr 1 with oxygen supplementation either in the operating room or intensive care to demonstrate that with oxygen supplementation the difference in the first-attempt success rate in favor of VL is negligible


Clinical Trial Description

Eligible children will be prepared for intubation according to the local SOPs of the pediatric anesthesia or pediatric intensive care departments. Mandatory monitoring will consist of: SpO2, HR, NIBP. Induction of anesthesia: All children included in this protocol will be pre-oxygenated before induction of anesthesia for one minute through face-mask with FiO2 = 1.0 and flow rates of 6-10L/min. The induction of anesthesia for tracheal intubation will be performed using a combination of sedative/hypnotic drugs, opioids and non-depolarizing muscle relaxant. The following medications will be mandatory as per protocol: - A non-depolarizing muscle relaxant (NDMR) drug (Rocuronium 0.5-1 mg/kg, Cis-Atracurium 0.2-0.5 mg/kg, Vecuronium 0.1 mg/kg, or succinylcholine 2 mg/kg). - One or more of the following hypnotic agents (Thiopentone 4-7 mg/kg, Ketamine 0.5-2 mg/kg, Propofol 1-4 mg/kg, Midazolam 0.5-1 mg/kg, Sevoflurane up to 8%). An opioid drug and anticholinergic can be chosen and administered at the discretion of the anesthetist in charge Before intubation: After induction of anesthesia and the administration of a muscle relaxant drug, bag-mask ventilation with FiO2 = 1.0 (flow rates of 6-10 Lmin-1) will be performed for 60 seconds until apnea sets in. After induction all patients will be paralysed with e.g. 0.5-1 mg/kg of rocuronium (2 x ED95 (standard intubation dose)) to facilitate airway management. Neuromuscular blockade will be assessed by train-of-four (TOF) monitoring. Thereafter oxygen administration, laryngoscopy and tracheal intubation are performed. During intubation: The administration of oxygen during intubation is mandatory for every study participant and is standardized as follows: - Oral intubation: For all orally intubated children, the administration of low-flow oxygen (1 l/kg/min) takes place via conventional neonatal nasal cannula. After administration of low-flow oxygen laryngoscopy and tracheal intubation are performed. - Nasal intubation: For all nasally intubated children, the administration of low-flow oxygen (1 l/kg/min) takes place direct via nasal tube. The nasal tube is introduced into one of the two nostrils up to the nasopharyngeal space and oxygen is applied to the tube via oxygen cannula. After administration of low-flow oxygen laryngoscopy and tracheal intubation are performed. For a premature neonate < 1kg an uncuffed tube ID 2.5 will be used. For premature babies and newborn between 1kg and 3.0 kg an uncuffed tube ID 3.0 will be used. For babies > 3.0 kg a cuffed tube ID 3.0 or an uncuffed tube 3.5 will be used. The tube will be either passed through one of the two nostrils and advanced with the help of a Magill-forceps or through the mouth. Based on the group of randomization, the child will be intubated either using the C-MAC videolaryngoscope with a Miller blade 1 (Karl Storz, Germany) or using standard direct laryngoscope, with standard blades Miller nr 0 and Miller nr 1. Miller blade nr 0 will be used for children < 1 kg. In cases of unexpected difficult intubation, the difficult airway algorithm (14) will be followed. After the first unsuccessful intubation attempt with the randomized device, the investigators encourage to perform a second attempt with the same device but based on the clinical judgment the intubating physician can proceed to an attempt with the same technique, or change the laryngoscope blade size, switch from one technique to another and a maximum of 4 intubation attempts in total will be performed. The last intubation attempt must be performed by the most experienced physician in the room. Additional devices like stylet, bougie, etc, can be used at any stage of the intubation process. If the intubation remains unsuccessful the difficult airway algorithm will be followed and a supraglottic airway device - SAD will be inserted. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT04295902
Study type Interventional
Source University Hospital Inselspital, Berne
Contact
Status Completed
Phase N/A
Start date April 1, 2020
Completion date March 8, 2023

See also
  Status Clinical Trial Phase
Completed NCT03908411 - The Effect of Paratracheal Pressure on the Glottic View N/A
Completed NCT04564105 - Simulation Training and Teamwork Concerning Intubation on the Icu N/A
Completed NCT02988336 - TMHT - New Method of Difficult Intubation Prediction N/A
Completed NCT03002857 - Comparison of I-gel LMA, Classical LMA With a New Supraglottic Airway the Baska Mask® in Urological Surgery N/A
Recruiting NCT06337006 - Laryngeal Mask Airway Failure in Pediatric Patients
Completed NCT03443219 - RCT- LMA Supremeā„¢ Versus the Spritztube® Tracheal Cannula in Anesthetized Adult Patients N/A
Completed NCT05044416 - VieScope in Patients With an Expected Difficult Airway N/A
Not yet recruiting NCT05534451 - Comparison Among Three Different Video Scope Guided Nasotracheal Intubation. N/A
Recruiting NCT06073977 - Risk Factors for Pediatric Difficult Supraglottic Airway Placement and Ventilation
Not yet recruiting NCT03687424 - Can High-flow Nasal Oxygenation Improve Oxygen Saturation During Analgo-sedation in Obese Adults? N/A
Not yet recruiting NCT03687385 - The Effect of High-flow Nasal Oxygenation to the Saturation During Analgo-sedation in Different ASA Risk Class Patients N/A
Enrolling by invitation NCT05055401 - Airway Management Skills Amongst Anesthesia Providers
Not yet recruiting NCT02920879 - Airway Effects of PEEP During Anesthesia Induction. N/A
Terminated NCT02644837 - AuraGain and iGel Crossover Comparison N/A
Completed NCT02263300 - Spatial Orientation and Fiberoptic Intubation Skills in the Novice: A Randomized Controlled Trial
Completed NCT01718561 - The Difficult Airway Management Trial: "The DIFFICAIR-Trial" N/A
Completed NCT01635660 - Out-of-Hospital Randomized Comparison of Video-assisted Endotracheal Intubation N/A
Completed NCT00956592 - Clinical Evaluation of the Storz CMAC Laryngoscope N/A
Completed NCT00892671 - Airway Management and Vascular Access Simulation N/A
Completed NCT03848559 - Airway Management With Simulated Microgravity Using a Submerged Model N/A