Airway Management Clinical Trial
Official title:
Comparison of the Endotracheal Tube Cuff Pressure of a Taper-guard Cuffed Tube Between Ipsilateral and Contralateral Rotation of Head During Tympanoplasty; Prospective Study.
This study evaluates the endotracheal tube cuff pressure of a taper-guard cuffed tube during
tympanoplasty with ipsilateral rotation of head, compared to the contralateral rotation of
head.
The investigators will performed the ipsilateral rotation of head against the fixed tube in
half of participants or the contralateral rotation of head in the other half.
The inflation of the endotracheal tube cuff is very useful to prevent aspiration of
contaminated substances into lung past endotracheal tube and leakage of gas during positive
pressure ventilation. However, excessive inflation of endotracheal tube cuff frequently
causes tracheal mucosal damage, which can increase the incidence of sore throat, hoarseness,
and coughing after surgery.
Taper-guard cuffed tube was newly developed. Taper-guard endotracheal tube is more effective
in providing a sealing effect than a cylindrical endotracheal tube in an in vitro study.
However, recently, it was reported that the cuff pressure of a Taper-guard endotracheal tube
significantly increased after a positional change from the supine to the lateral flank
position, compared to that of a cylindrical endotracheal tube. However, during tympanoplasty,
the investigators need to rotate head for proper position.
In this study, therefore, the investigators investigate the difference of the endotracheal
tube cuff pressure of a taper-guard cuffed tube between ipsilateral and contralateral
rotation of head against the fixed tube during tympanoplasty.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03908411 -
The Effect of Paratracheal Pressure on the Glottic View
|
N/A | |
Completed |
NCT04564105 -
Simulation Training and Teamwork Concerning Intubation on the Icu
|
N/A | |
Completed |
NCT02988336 -
TMHT - New Method of Difficult Intubation Prediction
|
N/A | |
Completed |
NCT03002857 -
Comparison of I-gel LMA, Classical LMA With a New Supraglottic Airway the Baska Mask® in Urological Surgery
|
N/A | |
Recruiting |
NCT06337006 -
Laryngeal Mask Airway Failure in Pediatric Patients
|
||
Completed |
NCT03443219 -
RCT- LMA Supremeā¢ Versus the Spritztube® Tracheal Cannula in Anesthetized Adult Patients
|
N/A | |
Completed |
NCT05044416 -
VieScope in Patients With an Expected Difficult Airway
|
N/A | |
Not yet recruiting |
NCT05534451 -
Comparison Among Three Different Video Scope Guided Nasotracheal Intubation.
|
N/A | |
Recruiting |
NCT06073977 -
Risk Factors for Pediatric Difficult Supraglottic Airway Placement and Ventilation
|
||
Not yet recruiting |
NCT03687385 -
The Effect of High-flow Nasal Oxygenation to the Saturation During Analgo-sedation in Different ASA Risk Class Patients
|
N/A | |
Not yet recruiting |
NCT03687424 -
Can High-flow Nasal Oxygenation Improve Oxygen Saturation During Analgo-sedation in Obese Adults?
|
N/A | |
Enrolling by invitation |
NCT05055401 -
Airway Management Skills Amongst Anesthesia Providers
|
||
Terminated |
NCT02644837 -
AuraGain and iGel Crossover Comparison
|
N/A | |
Not yet recruiting |
NCT02920879 -
Airway Effects of PEEP During Anesthesia Induction.
|
N/A | |
Completed |
NCT02263300 -
Spatial Orientation and Fiberoptic Intubation Skills in the Novice: A Randomized Controlled Trial
|
||
Completed |
NCT01718561 -
The Difficult Airway Management Trial: "The DIFFICAIR-Trial"
|
N/A | |
Completed |
NCT01635660 -
Out-of-Hospital Randomized Comparison of Video-assisted Endotracheal Intubation
|
N/A | |
Completed |
NCT00956592 -
Clinical Evaluation of the Storz CMAC Laryngoscope
|
N/A | |
Completed |
NCT00892671 -
Airway Management and Vascular Access Simulation
|
N/A | |
Completed |
NCT03848559 -
Airway Management With Simulated Microgravity Using a Submerged Model
|
N/A |