Official title:
Reduction of Microemboli of Air Using a New Developed Air Trap (EmbolessTM) During Haemodialysis
During hemodialysis (HD) the blood of the patient pass an extracorporeal circuit that contains a dialyzer for rinsing and a venous chamber (air trap) to prevent from air embolism through the return blood into the patient. However, air traps in clinical use have limited capacity to prevent from microemboli of air to enter the return bloodline and deposit as emboli in the body such as lungs, heart and brain. The Investigator developed the air trap Emboless that was patented. In vitro studies showed significantly better reduction of microemboli contaminations than air traps compared to that in clinical use. The present randomized clinical trial compares two different air traps used by the same patients in a cross-over design (as pairs) using the Emboless compared with the Fresenius 4008/5008 (F5008). Chronic HD patients are randomized to perform the first HD with either their standard air trap (F5008) in the venous bloodline tubing or using the Emboless bloodline and vice versa. Each patient was included to make two paired series. A safety committee evaluates if significantly worse outcome appears especially with the Emboless, to stop the study. During HD the microbubbles are counted by a GAMPT ultrasound device using two probes. One probe is set at the inlet side of the air trap and the second at the outlet side. The outlet side represents data of microbubbles in the blood that are entering into the patient. Comparative non-parametric paired analyses are performed between the air traps. Monitoring of the study is performed.
During hemodialysis (HD) the blood of the patient pass an extracorporeal circuit that contains a dialyzer for rinsing and a venous chamber (air trap) to prevent from air embolism through the return blood into the patient. However, air traps in clinical use have limited capacity to prevent from microemboli of air to enter the return bloodline and deposit as emboli in the body such as lungs, heart and brain. The Investigator developed the air trap Emboless that was patented in Europe, USA and India. In vitro studies showed significantly better reduction of microemboli contaminations than air traps compared to that in clinical use. The present randomized clinical trial compares two different air traps used by the same patients in a cross-over design (as pairs) using the Emboless compared with the Fresenius 4008/5008 (F5008). Chronic HD patients are randomized to perform the first HD with either their standard air trap (F5008) in the venous bloodline tubing or using the Emboless bloodline and vice versa. Each patient is included to make two paired series. A maximum of 30 patients are planned. Each with 2 series of each two different sets of air traps that would give a total of 120 dialyses. A safety committee evaluates if significantly worse outcome appears especially with the Emboless. During HD the microbubbles are counted by a GAMPT ultrasound device using two probes. One probe is set at the inlet side of the air trap and the second at the outlet side. The outlet side represents data of microbubbles in the blood that are entering into the patient. Comparative non-parametric paired analyses are performed between the air traps. Monitoring of the study is performed. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT05980845 -
The Effect Nature Sounds and Music on Hemodialysis Patients
|
N/A | |
Recruiting |
NCT05020717 -
Retrospective Survey of Hyperkalemia in Hemodialysis
|
||
Recruiting |
NCT04046042 -
Virtual Reality Intradialysis: Last vs. First Part of the Session
|
N/A | |
Recruiting |
NCT04094038 -
The Effect of Intradialytic Parenteral Nutrition on Nutritional Status and Quality of Life in Hemodialysis Patients
|
Phase 4 | |
Completed |
NCT03311581 -
The Feasibility of Propofol TCI in Hemodialysis Patients Undergoing Arteriovenous Shunt Surgery
|
Phase 1 | |
Completed |
NCT05531175 -
REIKI APPLICATION PAIN, FATIGUE AND ITCHING IN HEMODIALYSIS PATIENTS
|
N/A | |
Completed |
NCT04057313 -
Coffee in Hemodialysis and Headache
|
N/A | |
Completed |
NCT03061552 -
Inferior Vena Cava Sonography in Hemodialysis Patients and Quality of Life
|
N/A | |
Completed |
NCT03251573 -
The Cohort Study of Cognitive Impairment in Chinese Hemodialysis Patients
|
||
Completed |
NCT03527680 -
Effect of Lactobacillus Rhamnosus on Serum Uremic Toxins in Hemodialysis
|
N/A | |
Completed |
NCT05568342 -
The Effect of Roy Adaptation-Based Nursing Intervention
|
N/A | |
Completed |
NCT04063423 -
Non- Clinical Coagulation Activation During Hemodialysis
|
||
Active, not recruiting |
NCT06203795 -
Dialysis Performance of the FX CorAL Membrane
|
N/A | |
Completed |
NCT04319328 -
Is Cefazolin, Ceftazidime and Ciprofloxacin Dosing Optimal in Hemodialysis Patients?
|
||
Completed |
NCT03627884 -
Outcomes of the Use of Sodium Bicarbonate (8.4%) Solution as a Catheter Lock Solution to Prevent Hemodialysis Catheter Loss Due to Lumen Clot Formation
|
Phase 4 | |
Completed |
NCT05132036 -
Lung Ultrasound Assessment of Fluid Overload in Haemodialysis Patients
|
N/A | |
Completed |
NCT03076528 -
An Innovative Virtually Supervised Exercise for Dialysis Patients
|
Phase 2 | |
Completed |
NCT06098443 -
Acupressure Versus Transcutaneous Electrical Nerve Stimulation on Pain and Quality of Life Intradialysis
|
N/A | |
Completed |
NCT04645121 -
Carbon Monoxide-based Rebreathing Method and Bioimpedance in Hemodialysis Patients
|
||
Recruiting |
NCT04127877 -
Bio Impedance-assisted Monitoring of Chronic Hemodialysis Patients
|
N/A |