Clinical Trials Logo

Clinical Trial Summary

The investigators test the hypothesis that oropharyngeal leak pressure and fiberoptic position differ between the size 2 LMA SupremeTM and the Laryngeal Tube LTS IITM in non-paralyzed anaesthetized pediatric patients


Clinical Trial Description

The Laryngeal Tube LTS IITM (VBM-Medizintechnik GmbH, Sulz a.N, Germany) is a well established reusable latex free, extraglottic airway device. A proximal (pharyngeal) and a distal (esophageal) cuff are inflated with a single cuff pilot line. In between lies the ventilation orifice. The LMA SupremeTM (Teleflex San Diego, CA, USA) is a single use well studied laryngeal mask airway. Both devices have a drain tube to allow access to the gastrointestinal tract. Actually there are no studies comparing Laryngeal Tube LTS IITM and LMA SupremeTM use in small children. Therefore the aim of this study was to evaluate the clinical performance of the Laryngeal Tube LTS IITM compared to the LMA SupremeTM. The investigators hypothesized that design differences should lead to differences in efficacy of seal and anatomic position. In this randomized, crossover study, the investigators test the hypothesis that in non-paralyzed pediatric patients the oropharyngeal leak pressure and fiberoptic position differs between the size 2 Laryngeal Tube LTS IITM and the LMA SupremeTM. ;


Study Design

Allocation: Randomized, Endpoint Classification: Efficacy Study, Intervention Model: Parallel Assignment, Masking: Single Blind (Investigator), Primary Purpose: Treatment


Related Conditions & MeSH terms


NCT number NCT02252120
Study type Interventional
Source Schulthess Klinik
Contact
Status Completed
Phase N/A
Start date January 2014
Completion date September 2014

See also
  Status Clinical Trial Phase
Not yet recruiting NCT01350076 - Liberal Versus Goal-directed Intraoperative Fluid Therapy in Pediatric Patients Phase 2
Withdrawn NCT02121951 - Quadratus Lumborum Block for Percutaneous Nephrostomy Phase 4
Not yet recruiting NCT02977559 - A Study Between the Laryngeal Tube Suction-Disposable and the Ambu AuraGain in Pediatric Patients N/A
Completed NCT01575236 - A Randomized Non Crossover Study of the GuardianTM Versus SupremeTM Laryngeal Mask Airway Phase 3
Recruiting NCT01898897 - Influence of Anesthesia Technique on Postoperative Evolution After Urogenital Surgical Interventions N/A
Completed NCT03015857 - Phenylephrine and Noradrenaline for Post Spinal Anesthesia Hypotension Phase 2
Completed NCT02884986 - Analgesia in Inguinal Hernia Repair Using a Cyclooxygenase-2-specific Inhibitor N/A
Completed NCT02859922 - Comparison Between the Supreme Laryngeal Mask Airway and the Laryngeal Tube Suction During Spontaneous Ventilation N/A
Completed NCT02856672 - Trial Comparing the Laryngeal Tube Suction Disposable and the Supreme Laryngeal Mask Airway N/A
Completed NCT00468598 - The Prognostic Value of Troponin T for Long-term Outcome After Cardiac Surgery N/A
Recruiting NCT02883192 - The Effect of Preventive Use of Ondansetron in the Cesarean Section Under Spinal Anesthesia N/A
Not yet recruiting NCT02866890 - The New Laryngeal Tube Suction-Disposable for Childrens N/A
Completed NCT02570269 - Prospective Comparison of Oral Intubation Via - Ambu® Aura Gain™ vs Slotted Guedel Tubus N/A
Not yet recruiting NCT02884843 - The New Intubating Laryngeal Tube Suction-Disposable N/A
Not yet recruiting NCT02884869 - Comparison of Direct Laryngoscopy With Blind Intubation Via Intubating Laryngeal Mask Airway N/A
Not yet recruiting NCT02884895 - A Comparison of Direct Laryngoscopy With Blind Intubation Via Intubating Laryngeal Tube Suction Disposable N/A
Completed NCT02884921 - Preemptive Analgesia Using Intravenous Paracetamol N/A