Bladder Cancer Clinical Trial
Official title:
Clinical Trial Protocol of Primary Study on Efficacy and Safety of Telesurgery for Patients With Tumors of the Urinary System Using Chinese Independently Developed "MicroHand" Surgical Robot System
One-arm clinical trial was adopted in this study. The surgeons performed remote urological surgery for patients through domestically produced "MicroHand" surgical robot system (Shandong Weigao Co., Ltd). The "MicroHand" surgical robot system consists of two physically separated subsystems named the "surgeon console" and "patient side cart". The surgeon console includes a stereo image viewer, two master manipulators, a control panel and several foot pedals. The patient side cart includes a passive arm that can slide in the up-down direction and be adjusted forward and backward, a swivel head that can rotate around the vertical axis, and three slave arms (one for the endoscopic camera and the other two for surgical instruments). The surgeon console (based in Qingdao) takes the surgeon's input and translates it into a control signal. After network transmission, the patient side cart (based in Anshun) translates the control signal into actual instrument manipulation. The 3D images captured by the endoscopic camera were simultaneously sent back to the screen of the surgeon console as visual feedback. Data between the surgeon console and the patient side cart were transmitted through a 5G network. The safety and effectiveness of the robotic system in remote clinical diagnosis and treatment were verified by the main judgment criterion and secondary judgment criterion. Six patients are planned to enroll in the clinical trial. Main judgment criterion: The robot-assisted telesurgery did not transfer to other types of surgery, such as open surgery or normal robot-assisted surgery. Secondary judgment criterion: operative time, blood loss, postoperative pain, preoperative adjusting time and hospitalization time. Patient enrollment: This trial aims to explore the safety and effectiveness of the domestically produced robotic system in remote clinical diagnosis and treatment through 5G network. Six patients are planned to enroll in the clinical trial, including 2 patients with adrenal tumor, 2 patients with bladder cancer and 2 patients with renal cell carcinoma.
Objective: This clinical trial aims to evaluate the efficacy and safety of telesurgery for patients with tumors of the urinary system using Chinese independently developed "MicroHand" Surgical Robot System through 5G network. Content: One-arm clinical trial was adopted in this study. The product was domestically produced "MicroHand" surgical robot system (Shandong Weigao Co., Ltd). Before entering the clinical study, the patients were fully informed and the written informed consent were signed. According to the inclusion criteria and exclusion criteria, the researchers will conduct a detailed screening to determine whether they are suitable for the clinical study. Telesurgery would be conducted for patients who met the inclusion criteria using "MicroHand" surgical robot system. Data between the surgeon console and the patient side cart were transmitted through a 5G network. The safety and efficacy of the robotic system in remote clinical diagnosis and treatment were verified according to the main judgment criterion and secondary judgment criterion. Background: With the combination of robotic and network communication technology, telesurgery has become a reality. On the one hand, telesurgery can conserve and optimize medical resources, providing high-quality medical services to unbalanced areas, such as rural areas, stricken areas and battlefields. On the other hand, telesurgery can reduce the time spent by patients waiting for treatment and thus prevent diseases from worsening. The unbalanced distribution of medical resources has been a prominent problem in China. In addition, the vast territory and relatively lower medical distribution ratio per capita make it difficult for patients to receive timely and high-quality treatment, especially those in remote and underdeveloped areas. Therefore, telesurgery is more significant in China. In recent years, surgical robot systems and network communication technology have experienced breakthroughs. The operation systems of the Da Vinci robot in America, the REVO-I robot in South Korea and the ALF-X robot in Italy are more flexible and intelligent, performing well in surgical procedures. The "Micro Hand S" system robot, independently developed in China, represents a new generation of surgical robot systems. In addition to the flexible and intelligent characteristics of traditional robots, it has a series of advantages, such as a clear interface, light weight, low cost in terms of use and maintenance, and strong equipment compatibility. After preliminary experiments, it has been successfully applied in clinical surgery6. Meanwhile, in the field of network communication, the emerging 5G mobile communication technology (the 5th generation of wireless systems, 5G technology for short) is the latest generation of cellular mobile communication technology. It is also an extension of 4G (LTE-A or WiMax), 3G (UMTS or LTE) and 2G (GSM) technology. 5G technology has a high data rate, low latency, high throughput, equipment connection on a large scale, low cost and low energy consumption. The emergence of 5G technology offers more opportunities for the prevalence of telesurgery. In September 2019, our research group carried out the first 5G remote telesurgery using the "Micro Hand S" system robot and a 5G network between Qingdao, Shandong Province, and Xixiu, Guizhou Province, in September 2019 in China (the network communication distance was nearly 3000 km). Specifically, the investigators conducted four ultra-remote laparoscopic surgeries, including left nephrectomy, partial hepatectomy, cholecystectomy and cystectomy in a swine model under the 5G network using a domestically produced "Micro Hand S" surgical robot. the investigators accomplished four laparoscopic telesurgeries successfully, with an average network delay of 264 ms (including a round-trip transporting delay of 114 ms and a 1.20% data package loss ratio). Moreover, the total blood loss was 25 ml and no complications occurred during the procedures. The investigators demonstrated that ultra-remote laparoscopic telesurgery can be performed safely and smoothly under the 5G network using domestically produced equipment. On such basis, our research group planned to carry out this clinical trial to evaluate the efficacy and safety of telesurgery for patients with tumors of the urinary system using Chinese independently developed "MicroHand" Surgical Robot System through 5G network. Introduction of the "MicroHand" surgical robot: The "MicroHand" surgical robot system consists of two physically separated subsystems named the "surgeon console" and "patient side cart". The surgeon console includes a stereo image viewer, two master manipulators, a control panel and several foot pedals. The patient side cart includes a passive arm that can slide in the up-down direction and be adjusted forward and backward, a swivel head that can rotate around the vertical axis, and three slave arms (one for the endoscopic camera and the other two for surgical instruments). The surgeon console (based in Qingdao) takes the surgeon's input and translates it into a control signal. After network transmission, the patient side cart (based in Anshun) translates the control signal into actual instrument manipulation. The 3D images captured by the endoscopic camera were simultaneously sent back to the screen of the surgeon console as visual feedback. Steps of the procedure: ① The surgeon console was placed in Qingdao, Shangdong Province, while the patient side cart was placed in Anshun, Guizhou Province. ② Connections between the surgeon console and the patient side cart were established through a public 5G wireless network. Special 5G customer premise equipment (CPE) was used as a signal repeater station and amplifier. Upload and download speed will be tested as network bandwidth. ③ After general anesthesia, the supine position was maintained, the surgical area was disinfected, and pneumoperitoneum was established from the left side of the umbilicus by using a Veress needle. Then, trocars were inserted, and slave arms were delivered. Slave arm A was equipped with robotic grasp pliers, and Slave arm C was equipped with an ultrasonic scalpel (bipolar pliers or electrocautery). Robot-assisted telesurgeries, including adrenalectomy, cystectomy and nephrectomy, were performed by surgeons from the departments of urology. Surgeons in Qingdao performed the dissection and coagulation of the target organs, while assistants in Anshun performed exposure of structures and clip application. Trocar placement and position of the patients were also adjusted in each telesurgery by the assistants if necessary. After completion of the dissection, the target organs were removed by the assistant bedside. Then the pneumoperitoneum was exsufflated and the incisions were closed. Intraoperative network latencies and vital signs were monitored constantly. The master-slave manipulation consistency was assessed subjectively. The operative time, blood loss and complications were recorded. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Not yet recruiting |
NCT06034015 -
A Study to Evaluate the Safety, Tolerability and Pharmacokinetics of Single and Multiple Ascending Doses of APL-1501 Extended Release (ER) Capsules Compared to APL-1202 Immediate Release (IR) Tablets in Healthy Volunteers
|
Phase 1 | |
Recruiting |
NCT04235764 -
En-bloc Transurethral Resection of Bladder Tumor (En-bloc TURBT) Specimens Using a Redesigned Surgical Resectoscope Device
|
||
Completed |
NCT02371447 -
VPM1002BC in Recurrent Non-muscle Invasive Bladder Cancer
|
Phase 1/Phase 2 | |
Recruiting |
NCT04081246 -
Transurethral Modified En Bloc Resection For Large Bladder Tumours.
|
N/A | |
Recruiting |
NCT06059547 -
Neoadjuvant Immunotherapy in Combination With the Anti-GDF-15 Antibody Visugromab (CTL-002) for Treatment of Muscle Invasive Bladder Cancer
|
Phase 2 | |
Terminated |
NCT04779489 -
Checkpoint Inhibitor and Radiation Therapy in Bulky, Node-Positive Bladder Cancer
|
N/A | |
Not yet recruiting |
NCT04493489 -
Propranolol Adjuvant Treatment of Bladder Cancer
|
Phase 2 | |
Completed |
NCT03520231 -
Study Comparing Denosumab With Standard Treatment in Urothelial Cancer Patients With Bone Metastases
|
Phase 2 | |
Recruiting |
NCT04537221 -
Nordic Cystectomy Study III - Transfusion
|
||
Withdrawn |
NCT03007771 -
Magnetic Resonance-guided High-Intensity Focused Ultrasound (MR-HIFU) Used for Mild Hyperthermia
|
Phase 1 | |
Completed |
NCT01955408 -
Severity of Overactive Bladder Symptoms in Patients After Synergo Treatment
|
N/A | |
Completed |
NCT04487457 -
Prospective Study to Evaluate the Blood Kinetics of Immune Cells and Immunosuppressive Cytokines After Exposure to an Immunity Checkpoint Inhibitor (ICI): Study of the Impact of Chemotherapy
|
||
Active, not recruiting |
NCT04383210 -
Study of Seribantumab in Adult Patients With NRG1 Gene Fusion Positive Advanced Solid Tumors
|
Phase 2 | |
Recruiting |
NCT05562791 -
A Study of 68Gallium PSMA-PET/CT Scans in People With Bladder Cancer
|
Phase 1 | |
Completed |
NCT00199849 -
NY-ESO-1 Plasmid DNA (pPJV7611) Cancer Vaccine
|
Phase 1 | |
Completed |
NCT02781428 -
To Detect the Sensitivity of the UroMark Assay
|
||
Recruiting |
NCT04738630 -
Study of HX008 for the Treatment of BCG-Unresponsive Non-muscle Invasive Bladder Cancer
|
Phase 2 | |
Completed |
NCT03980041 -
Study to Evaluate the Efficacy/Safety of IPI-549 in Combination With Nivolumab in Patients With Advanced Urothelial Carcinoma (MARIO-275)
|
Phase 2 | |
Active, not recruiting |
NCT03978624 -
Window of Opportunity Study of Pembrolizumab Alone and in Combinations in Bladder Cancer
|
Phase 2 | |
Completed |
NCT04534309 -
Behavioral Weight Loss Program for Cancer Survivors in Maryland
|
N/A |