Adolescent Idiopathic Scoliosis Clinical Trial
Official title:
The Effect of Conservative Treatment on Gait Biomechanics in Adolescent Idiopathic Scoliosis
Verified date | March 2024 |
Source | Medipol University |
Contact | n/a |
Is FDA regulated | No |
Health authority | |
Study type | Interventional |
Adolescent idiopathic scoliosis (AIS) is a three-dimensional complex progressive structural deformity of the growing spine. Asymmetric changes in both the anatomical structure and strength of the muscles due to deformity affect weight distribution and joint moments in the trunk and lower extremities. As the spine transfers loads through the pelvis, asymmetry in the spinal alignment creates structural or functional changes involving other parts of the kinetic chain. The deviations caused by the deformity in all three planes and the responses to it affect the kinetics and kinematics of the trunk and extremities. A number of kinetic and kinematic changes such as decreased hip muscle strength, asymmetric lateral stepping, decreased hip and pelvic joint range of motion, especially in the frontal and transverse planes, and ground reaction force asymmetry has been demonstrated in patients with AIS. Understanding the postural changes and correction strategies that affect the displacement of the center of mass, ground reaction force and center of pressure during standing and walking in adolescents with idiopathic scoliosis is fundamental to understanding the nature of the disease, disease management and guiding rehabilitation both conservative treatment and after surgery. Based on this, it was aimed to objectively measure the biomechanical effects of the forces applied to the body in the brace to control deformity and prevent progression during the growth period, to determine postural control strategies, kinetic and kinematic changes in these patients with treatment by applying MOOR-S model brace and Schroth Three-Dimensional Scoliosis Exercise Treatment as a conservative treatment method on patients with AIS. In addition, it was also aimed to determine lower extremity inequality by measuring dynamic leg length with gait analysis in individuals with functional leg length discrepancy due to scoliosis.
Status | Active, not recruiting |
Enrollment | 45 |
Est. completion date | December 2025 |
Est. primary completion date | December 2024 |
Accepts healthy volunteers | Accepts Healthy Volunteers |
Gender | All |
Age group | 10 Years to 18 Years |
Eligibility | Inclusion Criteria: - Patients, diagnosed with AIS and referred to brace center for conservative treatment by the physician - Cobb angle between of 20-45° - ages 10 to 18 years - no treatment before - Individuals with family consent will be included Exclusion Criteria: - Spine surgery - A history of major lower extremity trauma and associated surgery - Leg length inequality more than 1 cm - Other musculoskeletal pathologies that may affect gait - Presence of transitional vertebrae - Scoliosis due to other etiology - Presence of infection, tumor, rheumatic and neurological disease which affected spine |
Country | Name | City | State |
---|---|---|---|
Slovenia | University of Ljubljana | Ljubljana |
Lead Sponsor | Collaborator |
---|---|
Medipol University | Moor Orthotics and Prosthetics, University of Ljubljana |
Slovenia,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Body center of mass | Body center of mass and its displacement with the brace will assess with computerized 3D gait analysis: With the optoelectronic motion capture system by Qualisys Motion Capture System (Gothenburg, Sweden), assessments will be made with the bare feet while standing and walking. Walking speed is chosen by each individual. Six walking trials will be recorded for each individual on a 15-meter walking path. The system integrated with wireless EMG (Wireless EMG system Delsys) and force platforms (AMTI) has 12 high-resolution cameras and allows the sensing of movement in three planes by Gait Module for Qualisys Track Manager software with the help of marker placed on specific anatomical reference points in the body. Instituti Orthopedici Rizzoli (IOR) Full Body marker protocol was chosen to specify anatomical landmarks. | Change from baseline body center of mass at 3 months | |
Primary | Center of pressure | The Center of pressure and its displacement with the brace will assess with computerized 3D gait analysis: With the optoelectronic motion capture system by Qualisys Motion Capture System (Gothenburg, Sweden), assessments will be made with the bare feet while standing and walking. Walking speed is chosen by each individual. Six walking trials will be recorded for each individual on a 15-meter walking path. The system integrated with wireless EMG (Wireless EMG system Delsys) and force platforms (AMTI) has 12 high-resolution cameras and allows the sensing of movement in three planes by Gait Module for Qualisys Track Manager software with the help of marker placed on specific anatomical reference points in the body. Instituti Orthopedici Rizzoli (IOR) Full Body marker protocol was chosen to specify anatomical landmarks. Markers will be placed bilaterally at points on the extremity and both sides of the body. | Change from baseline center of pressure at 3 months | |
Primary | Thorax-pelvis coordination pattern | The dynamic deviation of the rotational thorax-pelvis segment position relative to the progression line will be measured. Thorax-pelvis coordination will reveal the relative rotational range of motion between the head, pelvis and upper body in the coordinate system with the information obtained from the relevant anatomical reference points as in the literature. Thorax-pelvis coordination pattern will assess with computerized 3D gait analysis: With the optoelectronic motion capture system by Qualisys Motion Capture System, assessments will be made with bare feet while standing and walking. The system integrated with wireless EMG and force platforms (AMTI) has 12 high-resolution cameras and allows the sensing of movement in three planes by Gait Module for Qualisys Track Manager software with the help of markers placed on specific anatomical reference points in the body. | Change from baseline thorax-pelvis coordination pattern at 3 months | |
Primary | Dynamic leg length | Dynamic leg length is the effective length of the lower limb, measured by the distance from the hip joint center to the heel, ankle joint center and forefoot, in order to determine possible functional LLD. Measuring dynamic leg length during the gait cycle takes into account the bony segmental length (foot segment, shank segment, thigh segment) and kinematic angles of the lower extremity in the sagittal, frontal and horizontal plane. Dynamic leg length will assess with computerized 3D gait analysis: With the optoelectronic motion capture system by Qualisys Motion Capture System (Gothenburg, Sweden), assessments will be made with bare feet while standing and walking. The system integrated with wireless EMG and force platforms (AMTI) has 12 high-resolution cameras and allows the sensing of movement in three planes by Gait Module for Qualisys Track Manager software with the help of marker placed on specific anatomical reference points in the body. | Change from baseline dynamic leg length at 3 months | |
Primary | Trunk, pelvis and lower extremity kinetics | Using anthropometric measurements, kinematic data and ground reaction force data, joints moments and forces will be calculated with the "inverse dynamics" method. Body kinetics (kinetic analysis) includes:
Ground reaction force: It will be measured in three planes as mediolateral, vertical and anteroposterior with the force platform of the system. Net moment (Nm/kg): The signals received from the muscles will be recorded by superficial EMG. As a result of the internal moment and external moment, the net moment and the flexor and extensor moment related to the dominant muscle group will be revealed. Power: The data obtained from the negative and positive mechanical power graphs will be examined concentric or eccentric contraction and power generation or absorption of the muscles. Body kinetics (kinetic analysis) will assess with computerized 3D gait analysis: With the optoelectronic motion capture system by Qualisys Motion Capture System |
Change from baseline trunk, pelvis and lower extremity kinetics at 3 months | |
Primary | Trunk, pelvis and lower extremity kinematics | Body kinematics (kinematic analysis): The position and orientation of the relevant body segments will be measured according to the global coordinate system using the information from the markers and anthropometric data. Through kinematic analysis, joint angles of the head, trunk and extremities in three planes in different phases of gait will be measured. Body kinematics will assess with computerized 3D gait analysis: With the optoelectronic motion capture system by Qualisys Motion Capture System (Gothenburg, Sweden), assessments will be made with bare feet while standing and walking. The system integrated with wireless EMG (Wireless EMG system Delsys) and force platforms (AMTI) has 12 high-resolution cameras and allows the sensing of movement in three planes by Gait Module for Qualisys Track Manager software with the help of marker placed on specific anatomical reference points in the body. | Change from baseline trunk, pelvis and lower extremity kinematics at 3 months | |
Primary | Time-distance parameters of gait | Time-distance parameters will be measured with the data obtained from the kinematic data and force platforms.
Walking speed Cadence Single and double stride length Stance and swing time Single and double support time Walk-Ratio Time-distance parameters will assess with computerized 3D gait analysis: With the optoelectronic motion capture system by Qualisys Motion Capture System (Gothenburg, Sweden), assessments will be made with bare feet while standing and walking. Walking speed is chosen by each individual. Six walking trials will be recorded for each individual on a 15-meter walking path. The system integrated with wireless EMG (Wireless EMG system Delsys) and force platforms (AMTI) has 12 high-resolution cameras and allows the sensing of movement in three planes by Gait Module for Qualisys Track Manager software with the help of marker placed on specific anatomical reference points in the body. |
Change from baseline time-distance parameters of gait at 3 months | |
Secondary | The angle of trunk rotation | The angle of trunk rotation will be measured by the scoliometer between T1-S1, and the highest value obtained in each part of the spine will be recorded. The angle of trunk rotation indicates the deviation in the transverse plane caused by vertebral rotation in that segment. The scoliometer developed by "Orthopedics Systems Incorporation®" will be used for the measurements. | Change from baseline the angle of trunk rotation at 3 months | |
Secondary | Cobb angle | Cobb angle is the sum of upper and lower end vertebra tilt angles in standing anterioposterior radiography. The included angle of the upper vertebra endplate line with the horizontal line is measured on the imaging data and the included angle of the lower vertebra endplate line with the horizontal line is measured on the imaging data. | Baseline | |
Secondary | Risser stage | The Risser sign is an indirect measure of skeletal maturity, whereby the degree of ossification of the iliac apophysis by x-ray evaluation is used to judge overall skeletal development. Risser stage will be defined using patients spine radiography and physician report. Risser sign consist 5 stages. Risser 0 indicates an immature skeleton while Risser 5 indicates a mature skeleton. | Baseline | |
Secondary | Deformity classification | Curvature classification will be defined using patients' spine radiography and physician report. Deformity classification will be given as in the gait analysis studies in the literature, indicating a direction and localization in the form of curvature as single thoracic, single lumbar/thoracolumbar and double major | Baseline | |
Secondary | Generalised joint hypermobility | The presence of generalised joint hypermobility will be evaluated with the nine-point Beighton test using the cut-off =5 points. Evaluation consists of five parameters; the first 4 items are evaluated symmetrically in all extremities and 1 point is given for each movement that can be performed. The 5th item is evaluated as 1 point: hyperextension of the MCP joint of the fifth finger >90°; abduction of the thumb to the forearm; elbow hyperextension >10°; knee hyperextension >10°; and touching the floor with the palms of the hands during trunk forward bend performed in a standing position | Baseline | |
Secondary | Health Related Quality of life | Quality of life in patients with AIS will be assessed using the SRS-22 Questionnaire. SRS-22 was developed by the Scoliosis Research Society to evaluate health-related quality of life (HRQL) in patients with adolescent idiopathic scoliosis (AIS). The SRS-22 questionnaire consists of 22 items Likert type scale that allows scoring between 1-5 for each question. SRS-22 has five domains including function, pain, mental health, self-image and satisfaction. Subgroups can be evaluated separately, or the total score is obtained by summing up the scores from all questions. The total score of each section ranges from 5 to 25, only the section evaluating satisfaction from the treatment is in the range of 2-10. Scoring is obtained by dividing the total score of each section by the number of questions in that section. Higher scores indicate better quality of life. | Change from baseline health related quality of life at 3 months |
Status | Clinical Trial | Phase | |
---|---|---|---|
Recruiting |
NCT03935295 -
Dysport ® as an Adjunctive Treatment to Bracing in the Management of Adolescent Idiopathic Scoliosis
|
Phase 4 | |
Recruiting |
NCT06262269 -
Interest of Adapted Physical Activity by Tele-rehabilitation in Chronic Pathology - Idiopathic Scoliosis in Adolescents
|
N/A | |
Not yet recruiting |
NCT06003010 -
Yoga for Adolescent Idiopathic Scoliosis (AIS) Patients
|
N/A | |
Withdrawn |
NCT02590380 -
Comparing Pedicle Screw Systems for the Treatment of Adolescent Paediatric Spine Deformity
|
N/A | |
Completed |
NCT02302534 -
Pilot Study of Functional and Morphometric Brain Abnormalities Related to Adolescent Idiopathic Scoliosis (MOR-FO-SIA)
|
N/A | |
Completed |
NCT05669859 -
Efficacy of Postoperative Telerehabilitation in Adolescent Idiopathic Scoliosis
|
N/A | |
Completed |
NCT05242601 -
Investigation of Quality of Life in Adolescent Idiopathic Scoliosis
|
||
Recruiting |
NCT05969301 -
Memory and Scoliosis Spinal Exercises
|
||
Recruiting |
NCT05919459 -
Effectiveness of Acceptance and Commitment Therapy Versus Active Controls in Improving Psychological Functions of Parents and Children With Adolescent Idiopathic Scoliosis: A Randomized Controlled Trial
|
N/A | |
Enrolling by invitation |
NCT05790031 -
Trials of Intelligent Nighttime Brace With Smart Padding to Treat of Adolescent Idiopathic Scoliosis
|
N/A | |
Active, not recruiting |
NCT04867148 -
The Prediction and Prevention of Disease by Using Big Data in Motion Analysis
|
N/A | |
Completed |
NCT05056363 -
The Effects of Core Stability Training in Children With Adolescent Idiopathic Scoliosis
|
N/A | |
Completed |
NCT00989495 -
Comprehensive Cohort Study of Bracing for Adolescent Idiopathic Scoliosis (AIS): A Feasibility Study
|
N/A | |
Withdrawn |
NCT00958373 -
Risk Factors for Psychiatric Disorders Associated With Adolescent Idiopathic Scoliosis
|
N/A | |
Recruiting |
NCT05730920 -
IV Methadone vs EXPAREL Erector Spinae Plane Blockade in Pediatric Subjects Undergoing Idiopathic Scoliosis Correction
|
Phase 4 | |
Recruiting |
NCT03292601 -
Brace Monitoring for Adolescent Idiopathic Scoliosis (AIS)
|
N/A | |
Completed |
NCT04421157 -
Exercises in Adolescent Idiopathic Scoliosis
|
N/A | |
Completed |
NCT05127902 -
Association Between Postural Balance and Muscle Activity of the Lumbar and Lower Limb Muscles in Female With or Without Adolescent Idiopathic Scoliosis (AIS) During Standing Balance Tasks With Upper Limb Movement
|
||
Completed |
NCT05703737 -
Respiratory Function and Respiratory Muscle Strength in Adolescent Idiopathic Scoliosis
|
||
Completed |
NCT04092335 -
Evaluation of Adam's Forward Bend Test and Smartphone Application in Screening of Adolescent Idiopathic Scoliosis
|