Adenoma Detection Rate Clinical Trial
Official title:
Usefulness of the Endo-AID Artificial Intelligence System in the Detection of Colorectal Adenomas. a Randomized Controlled Trial
The main purpose of the study to evaluate the usefulness of the Endo-AID artificial intelligence system in the detection of colorectal adenomas in consecutive patients for outpatient colonoscopy. The secondary aims were: - To evaluate the benefit of Endo-AID in adenoma detection rate by comparing endoscopists with high and low adenoma detection rate. - To evaluate serrated detection rate, advanced adenoma detection rate, adenoma detection rate according to the size (<= 5mm, 6-9mm,> = 10mm) and number of adenomas by colonoscopy. Stratification by location and morphology.
Priority guidelines have been established regarding IA applied to gastrointestinal endoscopy. Regarding the priority uses for their development, there are applications that improve vision, placing computer-assisted lesion detection (CADe) as one of the most necessary priorities, given the importance of colorectal cancer screening (CRC) and post-polypectomy surveillance. The evaluation of these systems in different clinical practices and patient groups has been recommend. In this regard, studies in the western population are limited and have been carried out by expert endoscopists. It has not been evaluated in endoscopists with different adenoma detection rates. In addition, there are no studies with the recent CADe Endo-AID system (Olympus Corp. Tokyo). The main purpose of the study to evaluate the usefulness of the Endo-AID artificial intelligence system in the detection of colorectal adenomas in consecutive patients for outpatient colonoscopy. In addition, the benefit of the CADe system will be assessed according to the endoscopist ADR. A randomized controlled trial will be carried out in consecutive outpatients meeting the inclusion criteria and none of the exclusion criteria. Patients with be randomized to one of the four groups: CADe system and high ADR endoscopist; CADe system and low ADR endoscopist; Control and high ADR endoscopist; Control and low ADR endoscopist. For the sample size calculation a 14.4 of difference in favor of the CADe system was considered. Taking onto account an alpha error of 0.05 in a unilateral contrast, a power of 80% and a loss of 10%, 165 patients per group would be required. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03442738 -
A Prospective Randomized Comparison of the Adenoma Detection Rate With a Disposable Cap (ENDOCUFF VISION®)
|
||
Completed |
NCT03041532 -
Impact of Proximal Colon Retroflexion in Colorectal Cancer Screening Programme
|
N/A | |
Not yet recruiting |
NCT05141773 -
Artificial Intelligence Aid Systems and Endocuff in Colorectal Adenoma Detection
|
N/A | |
Completed |
NCT03137277 -
A Study Between Two Instrument Generations to Improve Adenoma Detection in Screening Colonoscopy
|
||
Recruiting |
NCT05125939 -
Can Overall Adenoma Detection Rate Replace Screening Adenoma Detection Rate ? Multicenter Study
|
||
Recruiting |
NCT05863208 -
Artificial Intelligence-assisted Colonoscopy With or Without Endocuff Vision
|
N/A | |
Completed |
NCT04472741 -
Comparison of Newer Colonoscopy Devices With Standard Forward Viewing (SFV) Colonoscopes in Daily Practice
|
N/A | |
Recruiting |
NCT04963010 -
Impact of SFV of Proximal Colon on ADR
|
N/A | |
Completed |
NCT04086706 -
Retroflexion In The Ascending Colon Is A Costless Endoscopic Maneuver Increasing Adenoma Detection Rate
|
||
Not yet recruiting |
NCT03185299 -
Impact of Reinforced Education by Video on the Quality of Bowel Preparation
|
N/A | |
Completed |
NCT02507037 -
Effect of Gum Chewing on Bowel Cleansing Before Colonoscopy
|
Phase 4 | |
Completed |
NCT02540239 -
Premedication Simethione Improves Visibility During Bowel Cleansing for Colonoscopy
|
N/A | |
Completed |
NCT04397120 -
The Factors Affecting ADR of Screening Colonoscopy
|
||
Completed |
NCT01786213 -
Training Effects in Colonoscopy
|
N/A | |
Completed |
NCT06173297 -
Assessing the Agreement Between Endoscopic and Histopathological Diagnosis of Colorectal Sessile Serrated Lesions.
|
||
Not yet recruiting |
NCT03356015 -
Comparison Between 3-L and 4-L Polyethylene Glycol in Bowel Preparation
|
Phase 4 | |
Not yet recruiting |
NCT03352700 -
Premedication Dyclonine Improves Visibility During Bowel Cleansing for Colonoscopy
|
Phase 4 | |
Recruiting |
NCT04102631 -
A Multicenter Study Evaluating the Effectiveness of Endo.Angel in Improving the Quality of Colonoscopy
|
N/A | |
Not yet recruiting |
NCT02832869 -
Impact of Reinforced Education by Wechat and Short Message Service on the Quality of Bowel Preparation
|
Phase 4 |