Acute Circulatory Failure Clinical Trial
Official title:
Changes in Pulse Pressure Variations Induced by Passive Leg Raising Test to Predict Fluid Responsiveness in ICU
The passive leg raising (PLR) test is a reversible preload challenge of around 300 mL of blood that can be repeated as frequently as required without infusing a drop of fluid. Two recent meta-analyses of many studies have confirmed the reliability of the PLR test to predict fluid responsiveness in patients with acute circulatory failure. Nevertheless, the effects of the PLR must be assessed by the direct measurement of cardiac output since changes in arterial pressure do not allow the assessment of the PLR hemodynamic effects with reliability. Moreover, cardiac output must be measured continuously and in real time. In clinical practice, cardiac output measurement can be difficult for different reasons such as the unavailability of the echocardiography machine, or the absence of any continuous cardiac output monitoring technique at the time of acute circulatory failure occurrence. Recently, it was shown that the decrease in pulse pressure variation (PPV) induced by the mini-fluid challenge (100 mL of colloid solution infused in 1 min) was able to predict fluid responsiveness with reliability in patients ventilated with low tidal volume (<8 mL/kg of ideal body weight). Therefore, the investigators hypothesize that the changes in PPV induced by PLR test could be able to predict fluid responsiveness with reliability in mechanically ventilated patients with acute circulatory failure.
n/a
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT03680963 -
Early Versus Differed Arterial Catheterization in Critically Ill Patients With Acute Circulatory Failure:
|
N/A | |
Terminated |
NCT01090791 -
FLOTRAC/VIGILEO in Acute Circulatory Failure
|
N/A | |
Completed |
NCT04337983 -
Hemodynamic Characteristics of Patients With SARS-CoV-2
|
||
Recruiting |
NCT04946643 -
Subclavian Vein Diameter Variations to Assess Vascular Filling
|
||
Recruiting |
NCT03788772 -
Systems Analysis of Antigen Presenting Cells in Human Sepsis
|
N/A | |
Completed |
NCT04360304 -
Assessment of Agreement Between Two Measurement Methods of Left Ventricular Outflow Tract (LVOT) Velocity Time Integral (VTI)
|
N/A | |
Completed |
NCT02050269 -
Measuring the Plasma Clearance of Iohexol to Estimate Glomerular Filtration Rate in Intensive Care Unit Patients: Preliminary Feasibility Study
|
Phase 3 | |
Completed |
NCT01630577 -
Central Venous Pressure Change With Volume Challenge in Patients With Hemodynamic Instability
|
Phase 3 | |
Recruiting |
NCT05046340 -
Applicability of Fluid Responsiveness Indices in Circulatory Failure (AFRIC Study) Study Project
|
||
Completed |
NCT04250389 -
Microcirculatory Effects of Methylene Blue
|
||
Recruiting |
NCT05613647 -
Concordance Study of Therapeutic Decision-making in Patients With Shock Based on Hemodynamic Monitoring
|
||
Completed |
NCT05847998 -
Second Generation DICART Prototype Validation
|
N/A | |
Not yet recruiting |
NCT06384287 -
Peripheral Tissue Perfusion in Intensive Care
|
||
Recruiting |
NCT02878369 -
Evaluation of Doppler Flow From the Femoral Artery as a Reflection of Cardiac Flow in a Vascular Fluid Test
|
N/A | |
Completed |
NCT03694717 -
Time Course Evolution of Cardiac Output
|