Clinical Trials Logo

Clinical Trial Summary

Self-massage is a set of therapeutic techniques performed by the individual using instruments such as a foam roller (i.e., foam rolling [FR]). This technique has been used in rehabilitation to recover myofascial dysfunctions and in physical/sports training, to improve performance in functional and sports activities. Possible changes in the muscle's and tendon's mechanical properties may help to explain the FR effects, however, the dose-response relationship is not clear acutely. Furthermore, body composition also seems to influence the pressure applied to the different tissues during FR, since it can attenuate the forces applied on the tissues. Therefore, the aim of this study is to verify the acute effects of different FR volumes on the plantar flexors' musculotendinous properties in healthy individuals. Twenty healthy subjects (male and female) aged between 18-35 years will perform three different FR conditions: FR90 (3x30s), FR180 (3x60s), and a control condition (CTRL; without the application of any intervention) with a seven-day wash-out period. The Achilles tendon morphological, mechanical, and material properties, medial gastrocnemius passive muscular stiffness, plantar flexors' muscle architecture, and the adipose tissue's thickness, skin temperature and the jump height (assessed during the unilateral countermovement jump) will be obtained. Assessments will be carried out before and immediately after the FR application in the different conditions. Descriptive statistics (mean, standard deviation, and standard error) will be used to present the results. The normality and sphericity of the data will be evaluated using the Shapiro-Wilk and Mauchly tests, respectively. A two-way ANOVA (condition [FR90, FR180, and CTRL] and moments [pre- and post-intervention]) will be used to compare the results. A post-hoc Bonferroni test will be used to find possible differences. A Pearson product-moment correlation test (parametric data) or a Spearman correlation test (non-parametric data) will be used to verify the association between the adipose tissue's thickness and the evaluated parameters. The effect size (Cohen's d) of each condition will be obtained. Responsiveness to conditions (FR90, FR180, and CTRL) will be determined using the typical error.


Clinical Trial Description

Self-massage is a set of therapeutic technique performed by the individual using instruments such as a foam roller (i.e., foam rolling [FR]). This technique has been used in rehabilitation to recover myofascial dysfunctions and in physical/sports training, to improve performance in functional and sports activities. Possible changes in the muscle's and tendon's mechanical properties may help to explain the FR effects. Although some studies have found a decreased muscle stiffness after FR intervention, other studies have reported no changes in muscle stiffness. Furthermore, a single study investigated the FR effects on the tendon and found no stiffness changes post-intervention. The between-studies methodological procedures heterogeneity, especially the different FR protocols (e.g., pressure-volume) may partially justify conflicting results. However, the dose-response relationship is not clear acutely. Furthermore, body composition also seems to influence the pressure applied to the different tissues during FR. Therefore, the aim of this study is to verify the acute effects of different FR volumes on the plantar flexors' musculotendinous properties in healthy individuals. Twenty healthy subjects (male and female) aged between 18-35 years will perform three different FR conditions: FR90 (3x30s), FR180 (3x60s), and a control condition (CTRL; without the application of any intervention) with a seven-day wash-out period. The weight-bearing during the FR application will be obtained through ground reaction forces, measured through force platform. The Achilles tendon morphological properties (length and cross-sectional area) will be evaluated using ultrasonography. In order to evaluate the mechanical (stiffness, force, and elongation) and material (Young's modulus, stress, and strain) properties, three maximum voluntary isometric contractions (MVIC) will be performed in a plantar flexion ramp in the isokinetic dynamometer with ultrasonography. The tendon force will be corrected by the tibialis anterior coactivation and adjusted by the tendon displacement caused by joint rotation during MVIC. The tendon elongation will be monitored during CMVIC using the ultrasound. The medial gastrocnemius muscle stiffness will be calculated by the variation in a passive dorsiflexion torque (isokinetic dynamometer) and the variation in the muscle length (ultrasound). The adipose tissue's thickness also will be obtained from ultrasound. The skin temperature will be evaluated by a thermographic camera to investigate possible post-intervention changes. The unilateral countermovement jump performance will be evaluated by 2D kinematic data measurements, using a video camera. Assessments will be carried out before and immediately after the FR application in the different conditions. Descriptive statistics (mean, standard deviation, and standard error) will be used to present the results. The normality and sphericity of the data will be evaluated using the Shapiro-Wilk and Mauchly tests, respectively. A two-way ANOVA (condition [FR90, FR180, and CTRL] and moments [pre- and post-intervention]) will be used to compare the results. A post-hoc Bonferroni test will be used to localize possible differences. A Pearson product-moment correlation test (parametric data) or a Spearman correlation test (non-parametric data) will be used to verify the association between the adipose tissue's thickness on the evaluated parameters, classified as none (0.0), weak (0.1-0.3), moderate (0.4-0.6), strong (0.7-0.9), or perfect (1.0). The effect size (Cohen's d) of each condition will be obtained, classified as small effect size (< 0.20); moderate effect size (0.20-0.50); or large effect size (>0.80). Responsiveness to conditions (FR90, FR180, and CTRL) will be determined using the typical error. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT05801302
Study type Interventional
Source Federal University of Rio Grande do Sul
Contact
Status Recruiting
Phase N/A
Start date March 1, 2023
Completion date May 20, 2023

See also
  Status Clinical Trial Phase
Not yet recruiting NCT01225497 - Eccentric Exercise for Chronic Mid-portion Achilles Tendinopathy N/A
Completed NCT03479736 - A Study of Fluoroquinolones Exposure and Collagen-Related Serious Adverse Events
Recruiting NCT06214442 - Effects of the Menstrual Cycle on Triceps Surae Properties in Women
Not yet recruiting NCT02775201 - Plantaris Release for Non-insertional Achilles Tendinopathy N/A
Not yet recruiting NCT05498987 - Ultrasound Achilles Tendon Assessment N/A
Completed NCT03014739 - Evaluation of Shear Wave Elastography Reproducibility in Achilles Tendons and Plantar Fascia
Completed NCT03029910 - Eccentric Training and Cryotherapy Vs Eccentric Training and Whole Body Vibration in Achilles Tendinopathy N/A
Completed NCT02062567 - Ultrasonographic Guided Treatment of Acute Achilles Tendon Rupture. Evaluation of Two Novel Ultrasonographic Measurements N/A