Abdominal Aortic Aneurysm (AAA) Clinical Trial
Official title:
Assessment of the GORE® EXCLUDER® Conformable AAA Endoprosthesis In the Treatment of Abdominal Aortic Aneurysms
EVAR continues to evolve as a treatment option for AAA. New devices which are specifically designed to perform adequately across the spectrum of potential anatomic presentations for infrarenal EVAR are needed. The Department of Vascular Surgery at Catharina Hospital Eindhoven, The Netherlands initiates the EXCeL Registry. This study will assess the safety and effectiveness of the GORE® EXCLUDER® Conformable AAA Endoprosthesis (CEXC Device) in patients who meet the IFU anatomic criteria (≥15mm proximal neck length and ≤90˚ proximal neck angulation; and ≥10mm proximal neck length and ≤60˚ proximal neck angulation) and in patients with challenging anatomic presentation that may present outside the IFU anatomic criteria. Successful outcomes from this study will provide evidence to support the CEXC Device as an option for expanding EVAR to a broader patient population with more challenging anatomic presentations.
EXCeL Registry is a multi-center, post-market, non-interventional, non-randomized, single-arm, prospective observational study, initiated by the Department of Vascular Surgery at Catharina Hospital Eindhoven, The Netherlands. The study has a single-arm without controls, as it is descriptive in nature, 150 consented subjects from up to 10 high-volume sites across Europe will be included into this registry. Study enrollment is open to consecutively enrolled subjects who in the opinion of the investigator and according to Table A (p.9) -Anatomic measurement table and group specific- are suitable for being treated. An independent core lab will validate pre-requisite anatomy measurement to evaluate candidates for endovascular AAA repair with the GORE® EXCLUDER® Conformable AAA Endoprosthesis. EXCeL Registry does not intervene with the physician's decision to choose for endovascular treatment with a GORE® EXCLUDER® Conformable AAA Endoprosthesis. Follow-up measurements are requested at 1 month, 12 months, and yearly thereafter, as minimally required by the reporting standards for endovascular aortic aneurysm repair. Beyond this, sites can schedule the subject's follow-up visits as usual in their clinical practice, as this study does not intervene in or influence the follow-up regimen. For data completion it is, however, possible that a telephone-contact with subjects will be requested. This study will assess the safety and effectiveness of the GORE® EXCLUDER® Conformable AAA Endoprosthesis in patients who meet the IFU anatomic criteria and in patients with challenging anatomic presentation that may fall outside the IFU anatomic criteria and identified in the protocol as challenging anatomy treatment cohort. Consented subjects placed in the challenging anatomy cohort will be followed per the protocol and any data analysis on this cohort will be descriptive in nature only. Up to 11 clinical investigative Sites will enroll a total of 150 subjects to allow for the broad range of aortic necks lengths and aortic neck angulations to be in the study. Consecutive consented subjects meeting protocol criteria will be part of the enrollment strategy: - Subjects with neck length of ≥15 mm and neck angulation of ≤90° - Subjects with neck length of ≥10 mm and neck angulation of ≤60˚ An independent Core Lab will read each subjects' pre-operative CT images and measure neck length and neck angle. These core lab measurements will determine if subject's anatomy meets IFU criteria (regarding neck length and neck angle) or if this subject has to be placed in the challenging anatomy treatment cohort. The EXCeL Registry, by itself, has a prospective observational study design, and focuses on patients with infrarenal abdominal or aorto-iliac aneurysms with Regular and challenging anatomy, scheduled for EVAR treatment with the GORE® EXCLUDER® Conformable AAA Endoprosthesis. No hypotheses testing will be carried out within this study design. However, the EXCeL Registry aims at creating a database that can analyze the performance of the GORE® EXCLUDER® Conformable AAA Endoprosthesis in different anatomies. Sample size calculation was precision based in order to achieve a desirable confidence interval width. An assumption of freedom from any endpoint event of 90% and a desired Confidence Interval (CI) of 10% or less results in a sample size of 150. Calculations performed with PASS13. A Subject will be considered lost to follow-up and withdrawn from the study once they have missed two consecutive follow-up visits and three documented attempts have been made by the Investigator or designee to contact the Subject or next of kin. In the event that the Subject is lost to follow-up, the date of discontinuation of the study will be recorded as the last contact with the Subject by the investigative site. A Subject has completed the study when they have completed the three year follow-up visit. Any Subject that does not complete these requirements due to voluntary withdrawal, physician withdrawal, death, or any other reason will be considered a withdrawal. Data collected on each subject will be recorded on an online electronic CRF. A paper version of the CRFs may be printed at the sites to use as a working copy. Instructions for proper completion of the electronic CRF and how to use it online will be provided to the clinical site. The investigator or an authorized member of the investigational team must sign all completed CRFs, by using a unique signature code. This code will be provided to the user at the start of the study. The Statistics & Data Analysis team at the Department of Vascular Surgery, Catharina Hospital, Eindhoven will check the data entered on the CRFs for consistency and completeness on a regular basis, both manually as well as by using statistical monitoring of the clinical database. Sites will be contacted for data inconsistencies in order to recover incomplete, inconsistent, or missing data. In case of multiple futile attempts of data completeness data and non-respond from clinical sites monitors of the Department of Vascular Surgery, Catharina Hospital, Eindhoven will visit sites. They will then collect data from source documents in a final attempt to complete the applicable CRFs. To enhance data quality, additional site visits may be conducted to crosscheck CRFs with patient files in approximately 20% of enrolled subjects. The local investigator will timely be informed of this scheduled visit. ;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT01480206 -
Overlay of 3D Scans on Live Fluoroscopy for Endovascular Procedures in the Hybrid OR
|
||
Terminated |
NCT04592991 -
CCR2 AAA Pilot Study
|
Early Phase 1 | |
Active, not recruiting |
NCT02009644 -
Clinical Study of the Treovance Stent-Graft for Patients With Abdominal Aortic Aneurysms
|
N/A | |
Completed |
NCT01990950 -
Fenestrated AAA Endovascular Graft Post-Approval Study
|
N/A | |
Withdrawn |
NCT04551183 -
Comparative Study of a Software With the Gold Standard
|
N/A | |
Completed |
NCT02306304 -
Ultra-sound for AAA Screening in Smoking Israeli Arab Men
|
N/A | |
Recruiting |
NCT02295137 -
Image Fusion of Preprocedural CTA With Real Time Fluoroscopy to Enhance EVAR Repair
|
Phase 1 | |
Recruiting |
NCT04586452 -
NIH CCR2 AAA Study
|
Early Phase 1 | |
Completed |
NCT01726257 -
Safety and Effectiveness Study of Endovascular Abdominal Aortic Aneurysm Repair Using the Nellix® System
|
N/A | |
Terminated |
NCT02007252 -
ACZ885 for the Treatment of Abdominal Aortic Aneurysm
|
Phase 2 | |
Completed |
NCT02934087 -
Endovascular Aneurysm Repair (EVAR) Gate Study
|
N/A | |
Terminated |
NCT03231397 -
Predictors of AAA Expansion and/or Rupture
|
Phase 4 | |
Completed |
NCT04333641 -
Development of Novel Imaging Markers Predicting the Progression of Abdominal Aortic Aneurysm Using 3D Computed Tomography
|