Type 1 Diabetes Mellitus Clinical Trial
Official title:
Assessment of a Novel Sensing Catheter During Automated Insulin Delivery in Patients With Type 1 Diabetes
The study described within this protocol is designed to test a single hormone closed-loop algorithm for managing blood glucose in type 1 diabetes using insulin only and a new device for measuring glucose continuously in the immediate vicinity of subcutaneous insulin delivery. Subjects will undergo one all day closed loop study using insulin only. The closed loop insulin only system includes a Dexcom G5 transmitter, a Nexus 5 smart phone and two Tandem tslim pumps connected to two Pacific Diabetes Technologies glucose sensing cannulas. The closed loop system will be started after G5 2 hour sensor start-up with an IV catheter for frequent blood withdrawal for 10 hours.
Subjects will undergo one 12 hour inpatient study. During this intervention visit, subjects
will wear the single hormone closed loop system which includes two t:slim insulin pumps to
deliver insulin or saline through two investigational PDT glucose sensing cannulas, and a
Dexcom G5 CGM to measure glucose. The subject will come to the research center at
approximately 7am for the inpatient visit. The Dexcom G5 sensor and PDT glucose sensing
cannulas will be placed after arrival. An 18-22 gauge IV catheter will be placed for blood
sampling every 15 minutes after sensor warm-up is complete for measuring blood glucose
concentration. After a 2 hour warm-up period for the G5 sensor, glucose will be controlled
using the FMPD single hormone mode. The single hormone mode of the controller determines
insulin delivery rates based on proportional and derivative error through one t:slim insulin
pump. The second t:slim insulin pump will deliver normal saline at the same delivery rates as
the insulin. Subjects will eat breakfast and lunch at approximately 11 am and 3 pm
respectively. Subjects will have the ability to complete light exercise on a treadmill. The
closed loop system will be stopped at approximately 6pm with removal of all devices.
During the study, the subject will wear one subcutaneous DexcomTM G5 continuous glucose
monitoring (CGM) system. The CGM system will provide sensed glucose data every 5 minutes. The
accuracy of the sensed data will be obtained by reference measurements of two YSI venous
blood glucose values to calibrate the sensor at the beginning of the closed loop study.
Sensed glucose data will be wirelessly transmitted via Bluetooth Low Energy (BTLE) from the
Dexcom G5 transmitter to the Nexus 5 master controller every five minutes. The controller is
a Google Nexus 5 phone. The smart phone will wirelessly communicate via BTLE to two Tandem
t:slim insulin pumps, one for automated insulin delivery and one of automated saline
delivery.
;
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04476472 -
Omnipod Horizon™ Automated Glucose Control System Preschool Cohort
|
N/A | |
Completed |
NCT03635437 -
Evaluation of Safety and Diabetes Status Upon Oral Treatment With GABA in Patients With Longstanding Type-1 Diabetes
|
Phase 1/Phase 2 | |
Completed |
NCT04909580 -
Decision Coaching for Youth and Parents Considering Insulin Delivery Methods for Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT00679042 -
Islet Transplantation in Type 1 Diabetic Patients Using the University of Illinois at Chicago (UIC) Protocol
|
Phase 3 | |
Completed |
NCT03293082 -
Preschool CGM Use and Glucose Variability in Type 1 Diabetes
|
N/A | |
Completed |
NCT04016662 -
Automated Insulin Delivery in Elderly With Type 1 Diabetes (AIDE T1D)
|
Phase 4 | |
Completed |
NCT02527265 -
Afrezza Safety and Pharmacokinetics Study in Pediatric Patients
|
Phase 2 | |
Completed |
NCT03738865 -
G-Pen Compared to Glucagen Hypokit for Severe Hypoglycemia Rescue in Adults With Type 1 Diabetes
|
Phase 3 | |
Completed |
NCT03240432 -
Wireless Innovation for Seniors With Diabetes Mellitus
|
N/A | |
Completed |
NCT03168867 -
Effectiveness Trial of an E-Health Intervention To Support Diabetes Care in Minority Youth (3Ms)
|
N/A | |
Completed |
NCT03674281 -
The VRIF Trial: Hypoglycemia Reduction With Automated-Insulin Delivery System
|
N/A | |
Completed |
NCT03669770 -
Ultrasound Classification and Grading of Lipohypertrophy and Its Impact on Glucose Variability in Type 1 Diabetes
|
||
Recruiting |
NCT03682640 -
Azithromycin Insulin Diet Intervention Trial in Type 1 Diabetes
|
Phase 2 | |
Recruiting |
NCT04096794 -
Chinese Alliance for Type 1 Diabetes Multi-center Collaborative Research
|
||
Completed |
NCT02882737 -
The Impact of Subcutaneous Glucagon Before, During and After Exercise a Study in Patients With Type 1 Diabetes Mellitus
|
N/A | |
Recruiting |
NCT02745808 -
Injectable Collagen Scaffold™ Combined With HUC-MSCs for the Improvement of Erectile Function in Men With Diabetes
|
Phase 1 | |
Withdrawn |
NCT02518022 -
How to be Safe With Alcoholic Drinks in Diabetes
|
N/A | |
Completed |
NCT02596204 -
Diabetes Care Transformation: Diabetes Data Registry and Intensive Remote Monitoring
|
N/A | |
Completed |
NCT02562313 -
A Trial Investigating the Continuous Subcutaneous Insulin Infusion of a Liquid Formulation of BioChaperone Insulin Lispro in Comparison to Humalog®
|
Phase 1 | |
Completed |
NCT02558491 -
Feasibility of a Decision Support System to Reduce Glucose Variability in Subject With T1DM
|
N/A |