Adolescents and young adults with type 1 diabetes often have a difficult time achieving good glucose control, which is so important in reducing the risk for diabetes complications. Despite the use of multiple daily injections or insulin pumps and glucose sensors, there is still a need for many individuals to further improve glucose levels without causing low blood glucose levels (hypoglycemia) or adding to the daily burden of living with diabetes. Today an insulin pump can receive glucose readings from a continuous glucose monitor and adjust the insulin delivery in an attempt to keep glucose levels in a more optimal range. These systems are called hybrid closed loop (HCL). This means that much of the insulin delivery is automated, yet the patient still interacts regularly with the system, particularly to help determine the insulin dose to deliver to cover a meal. Results of early studies using HCL systems in adolescents and adults with type 1 diabetes are encouraging. The objective of this study is to compare the efficacy and safety of the automated insulin delivery (AID) system with proportional integral-derivative (PID) algorithm (Minimed 670G 3.0 HCL) to an AID system with combined PID and Fuzzy Logic Algorithm (Minimed 670G 4.0 Advanced Hybrid Closed-Loop (AHCL)). The trial will test the hypothesis that the Minimed AHCL can reduce daytime hyperglycemia, currently the biggest challenge for AID systems, without increasing hypoglycemia. Up to 124 adolescents and young adults (ages 14-<30) will be recruited to test each system for three months in a randomized crossover trial. Investigators will compare how effective each hybrid closed loop system is at preventing high blood glucose readings during the day. The investigators will also evaluate the safety of each system and how participants adjust to the daily use of the technology.


Clinical Trial Description

Purpose of the study: A randomized crossover trial involving up to four clinical sites in the United States and three sites outside the US (Germany, Israel and Slovenia) will compare the efficacy and safety of an AID system with a PID algorithm versus an AID system with a PID algorithm enhanced with a fuzzy logic algorithm. Study Objectives: 1. EFFICACY: The co-primary outcomes are difference in continuous glucose monitoring (CGM)-measured metrics between periods: - Superiority for percent of time >180 mg/dL (10.0 mmol/L) from 6 AM to 11:59 PM; and - Non-inferiority of percent of time <54 mg/dL (3.0 mmol/L) during the entire 24-hour period. 2. KEY SAFETY OUTCOMES: - Percentage of sensor glucose readings <54 mg/dL (overall is a co-primary outcomes) and <70 mg/dL (3.0 and 3.9 mmol/L, respectively) - Diabetic Ketoacidosis (DKA) events - Severe hypoglycemia events Study design: Randomized crossover trial with two 12-week crossover periods in automode, preceded by a run-in phase. Population: A maximum of 124 individuals may be enrolled and start the run-in phase. Approximately 112 are expected to enter the crossover trial, with a goal of at least 100 people completing the trial. Maximum duration of a study for a subject: Approximately 28-36 weeks. Recruitment: Subjects will be recruited through the clinical sites. Consent: Written consent/assent will be obtained for all subjects and/or guardians, in accordance with human subjects and regulatory requirements. Screening Assessments: - Informed consent will be signed and eligibility will be assessed - Medical history and physical examination - HbA1c measurement - Urine pregnancy test (if applicable) - Surveys investigating participants' quality of life, psychosocial and cognitive functioning, and response to their current treatment will be distributed. Study Training: Run-In Period: (2-8 weeks) * Eligible participants will use the study 670G 3.0 HCL pump during the run-in. Participants who were pump users at screening may skip the Pump Run-In period (but must participate in the Pump+CGM Run-In period) per investigator discretion. 670G auto mode users may use the 670G pump in auto mode. Screening and start of run-in training visits may occur on the same day or separate days, but no more than 14 days apart. Standardized pump training will be provided to study participants and their diabetes care partners (for participants <18 years old). The study team will assist the participant in study pump infusion site initiation and will start the participant on the study pump. For current pump users, the study pump will be programmed with the participants usual basal rates and pump parameters. The participants personal pump will be removed. Participants may continue to use their personal CGM if applicable. The pump will be used for at least two weeks during the Pump Run-In, with the option of repeating Pump Run-In for an additional two weeks per investigator discretion. Contact will be made each week with additional contacts as needed. Prior to each contact, participants will be asked to upload device data for study staff to review. After completion of Pump Run-In, participants will proceed to use the study CGM along with the study 670G HCL pump during the Pump+CGM Run-In period. * Pump+CGM Run-In (670G 3.0 HCL + Guardian Sensor (3)) All participants must complete a two-week run-in period with the use of the study pump and CGM before being randomized into the crossover trial. During Pump+CGM Run-In, the predictive low glucose suspend feature will be turned on and auto mode will be off (i.e. manual mode). Participants who were 670G auto mode users at screening may use the pump in auto mode. Standardized device training will be provided to study participants and their diabetes care partners (for participants <18 years old). Personal pumps and CGMs will be removed during the Pump+CGM Run-In period as applicable. Contact will be made each week with additional contacts as needed. Prior to each contact, participants will be asked to upload device data for study staff to review. Run-In Assessment Successful completion of Pump Run-In is per investigator discretion. Pump Run-In may be repeated once. Successful completion of the Pump+CGM Run-In requires CGM data to be collected on at least 80% of the possible time in the prior 14 days of use. An average of at least three blood glucose meter (BGM) tests per day also will be required. If these are not achieved, the Pump+CGM Run-In period may be repeated once. Randomization into the Crossover Trial Eligible participants who successfully complete the Pump+CGM Run-In will be randomly assigned to begin with one Automated Insulin Delivery (AID) system during Period 1 and then crossover to the other AID system during Period 2. The two study AID systems (treatments) are: - 670G 3.0 Hybrid Closed-Loop (HCL) (PID) insulin pump + Guardian Sensor (3) CGM - 670G 4.0 Advanced Hybrid Closed-Loop (AHCL) (PID + Fuzzy Logic) insulin pump + Guardian Sensor (3) CGM Home Use of AID System during the Crossover Trial Period 1 (~13 weeks) Participants and their diabetes care partners (for participants <18 years old) will be trained by qualified personnel on the use of the assigned pump and on auto mode feature use including meal announcement, meal bolusing, and exercise. Training will also be provided in performing specific tasks including the following: - Confirming pump parameters - When not to use or rely on auto mode particularly during significant illness or acetaminophen use - CGM calibration instructions - Meal bolus procedures - What to do when exercising while using the system - How to react to safety/alert notifications - How to perform fingerstick blood glucose measurements in accordance with the labeling of the study CGM device - When and how to contact study staff to ask questions during the study Study staff will discuss the visit and contact schedule with the participant and will make arrangements for follow-up appointments. Participants will be asked to upload data before each contact and at least every two weeks. After auto mode training has been completed, participants will proceed with home use of the AID system (meaning free-living use at work, home, etc.) during Period 1 with either the 670G 3.0 HCL or 670G 4.0 AHCL pump. The predictive low glucose suspend feature will be on. The system will initially be used with auto mode deactivated (except for 670G auto mode users at screening who may activate auto mode if using the 670G 3.0 HCL pump) until participants are contacted 6-10 days into Period 1 with instructions to activate auto mode. Participants will be instructed to obtain an overnight fingerstick blood glucose measurement (between 2-3AM) for 2-3 nights following auto mode initiation and if fingerstick blood glucose is <70 mg/dL to treat with carbohydrate. Participants will then continue using the AID system for 12 weeks after auto mode is initialized. Participants will be expected to use auto mode at all times at home with some exceptions (e.g. times of illness, acetaminophen use). Participants on the 670G 4.0 AHCL will begin with an auto mode target glucose set point of 120 mg/dL (6.7 mmol/L) that may be lowered to 100 mg/dL (5.6 mmol/L) if participant meets the safety criteria per protocol and investigator discretion. HbA1c, C-peptide, and glucose levels will be collected for central lab analysis at the beginning of Study Period 1. Human Factors and Diabetes Technology Attitude Surveys will be administered at the end of Study Period 1. Period 2 (~13 weeks) At the beginning of Period 2, a urine pregnancy test will be completed as applicable. Eligible participants will then use the other AID system during Period 2. The procedures in Period 1 will be repeated in Period 2. At the end of the 12-weeks of AID use in auto mode at home, the participant will complete a final study visit. That visit may be completed in-person in clinic or in an alternate location such as the participant's home. The study visit may occur remotely via phone or videoconferencing. Certain procedures, such as the measurement of height, weight, vitals, and collection of the central HbA1c sample, may be missed if the visit is not completed in-person. Participants requiring a remote final visit will be transitioned off of the study device during the remote contact and an arrangement will be made between site staff and the participant to return all required study devices either in-person or via mail. ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03040414
Study type Interventional
Source HealthPartners Institute
Contact
Status Completed
Phase N/A
Start date June 3, 2019
Completion date April 20, 2020

See also
  Status Clinical Trial Phase
Completed NCT04476472 - Omnipod Horizon™ Automated Glucose Control System Preschool Cohort N/A
Completed NCT03635437 - Evaluation of Safety and Diabetes Status Upon Oral Treatment With GABA in Patients With Longstanding Type-1 Diabetes Phase 1/Phase 2
Completed NCT04909580 - Decision Coaching for Youth and Parents Considering Insulin Delivery Methods for Type 1 Diabetes N/A
Active, not recruiting NCT00679042 - Islet Transplantation in Type 1 Diabetic Patients Using the University of Illinois at Chicago (UIC) Protocol Phase 3
Completed NCT03293082 - Preschool CGM Use and Glucose Variability in Type 1 Diabetes N/A
Completed NCT04016662 - Automated Insulin Delivery in Elderly With Type 1 Diabetes (AIDE T1D) Phase 4
Completed NCT02527265 - Afrezza Safety and Pharmacokinetics Study in Pediatric Patients Phase 2
Completed NCT03738865 - G-Pen Compared to Glucagen Hypokit for Severe Hypoglycemia Rescue in Adults With Type 1 Diabetes Phase 3
Completed NCT03240432 - Wireless Innovation for Seniors With Diabetes Mellitus N/A
Completed NCT03168867 - Effectiveness Trial of an E-Health Intervention To Support Diabetes Care in Minority Youth (3Ms) N/A
Completed NCT03674281 - The VRIF Trial: Hypoglycemia Reduction With Automated-Insulin Delivery System N/A
Completed NCT03669770 - Ultrasound Classification and Grading of Lipohypertrophy and Its Impact on Glucose Variability in Type 1 Diabetes
Recruiting NCT03682640 - Azithromycin Insulin Diet Intervention Trial in Type 1 Diabetes Phase 2
Recruiting NCT04096794 - Chinese Alliance for Type 1 Diabetes Multi-center Collaborative Research
Completed NCT02882737 - The Impact of Subcutaneous Glucagon Before, During and After Exercise a Study in Patients With Type 1 Diabetes Mellitus N/A
Recruiting NCT02745808 - Injectable Collagen Scaffold™ Combined With HUC-MSCs for the Improvement of Erectile Function in Men With Diabetes Phase 1
Completed NCT02562313 - A Trial Investigating the Continuous Subcutaneous Insulin Infusion of a Liquid Formulation of BioChaperone Insulin Lispro in Comparison to Humalog® Phase 1
Withdrawn NCT02518022 - How to be Safe With Alcoholic Drinks in Diabetes N/A
Completed NCT02558491 - Feasibility of a Decision Support System to Reduce Glucose Variability in Subject With T1DM N/A
Completed NCT02596204 - Diabetes Care Transformation: Diabetes Data Registry and Intensive Remote Monitoring N/A