Type 1 Diabetes Mellitus Clinical Trial
Official title:
The Accuracy Benefit of Dual vs Single Amperometric Glucose Sensors in Persons With Type 1 Diabetes: Effect of Inter-sensor Distance
The purpose of the study is to test the accuracy benefit of having two glucose sensors (over one sensor alone) when they are positioned: 2mm, 10mm, 20mm, or 30mm apart. It is not yet known how close two sensors can be and still work correctly.
Status | Completed |
Enrollment | 20 |
Est. completion date | January 2011 |
Est. primary completion date | January 2011 |
Accepts healthy volunteers | No |
Gender | Both |
Age group | 18 Years to 65 Years |
Eligibility |
Inclusion Criteria: 1. Type 1 diabetes mellitus diagnosed for at least 6 months 2. Current usage of multiple daily injections or subcutaneous insulin pump treatment 3. Age 18-65 years 4. HbA1c of 6.0 - 9.5% at screening visit 5. BMI 21-35 6. Willingness to follow all study procedures, including attending all clinic visits 7. Willingness to sign informed consent and HIPAA documents Exclusion Criteria: Subjects presenting with any of the following will not be included in the study. 1. Pregnancy or Lactation: for women of childbearing potential there is a requirement for a negative urine pregnancy test. 2. Renal insufficiency (serum creatinine of 2.0 mg/dL or greater). Serum ALT or AST equal to or greater than 3 times the upper limit of normal; hepatic synthetic insufficiency as defined as a serum albumin of less the 3.3 g/dL; or serum bilirubin of over 2. 3. Hematocrit of less than or equal to 34%. 4. Congestive heart failure, NYHA class III or IV. 5. Visual impairment preventing reading of glucose meter values. 6. Active coronary artery disease as manifested by unstable angina, or a myocardial infarction or therapeutic coronary percutaneous procedure (e.g., PTCA, stent placement) or CABG within the past 4 months. 7. Active foot ulceration. 8. Severe peripheral arterial disease characterized by ischemic rest pain or severe claudication. 9. Cerebrovascular accident within the past 6 months. 10. Active alcohol abuse, substance abuse, or severe mental illness (as judged by the principal investigator). 11. Active malignancy, except basal cell or squamous cell skin cancers. 12. Major surgical operation within 30 days prior to screening. 13. Seizure disorder (epilepsy). 14. Any concurrent illness, other than diabetes, that is not controlled by a stable therapeutic regimen. 15. Currently administration of oral or parenteral corticosteroids. 16. Use of an investigational drug within 30 days prior to screening. 17. Bleeding disorder, treatment with warfarin, or platelet count below 50,000. |
Observational Model: Case-Only, Time Perspective: Prospective
Country | Name | City | State |
---|---|---|---|
United States | Oregon Health & Science University | Portland | Oregon |
Lead Sponsor | Collaborator |
---|---|
Oregon Health and Science University | The Leona M. and Harry B. Helmsley Charitable Trust |
United States,
Castle JR, Engle JM, El Youssef J, Massoud RG, Yuen KC, Kagan R, Ward WK. Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes. Diabetes Care. 2010 Jun;33(6):1282-7. doi: 10.2337/dc09-2254. Epub 2010 Mar 23. — View Citation
Schmidtke DW, Pishko MV, Quinn CP, Heller A. Statistics for critical clinical decision making based on readings of pairs of implanted sensors. Anal Chem. 1996 Sep 1;68(17):2845-9. — View Citation
Ward WK, Casey HM, Quinn MJ, Federiuk IF, Wood MD. A fully implantable subcutaneous glucose sensor array: enhanced accuracy from multiple sensing units and a median-based algorithm. Diabetes Technol Ther. 2003;5(6):943-52. — View Citation
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Difference between very large sensor accuracy errors (=50% from reference glucose) with the simultaneous use of four sensors vs one sensor. | 9-hour collection period, X 2 | No | |
Secondary | Difference between mean absolute relative difference with the simultaneous use of four sensors vs one sensor. | 9-hour glucose level collection, X 2 | No |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04476472 -
Omnipod Horizon™ Automated Glucose Control System Preschool Cohort
|
N/A | |
Completed |
NCT03635437 -
Evaluation of Safety and Diabetes Status Upon Oral Treatment With GABA in Patients With Longstanding Type-1 Diabetes
|
Phase 1/Phase 2 | |
Completed |
NCT04909580 -
Decision Coaching for Youth and Parents Considering Insulin Delivery Methods for Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT00679042 -
Islet Transplantation in Type 1 Diabetic Patients Using the University of Illinois at Chicago (UIC) Protocol
|
Phase 3 | |
Completed |
NCT03293082 -
Preschool CGM Use and Glucose Variability in Type 1 Diabetes
|
N/A | |
Completed |
NCT04016662 -
Automated Insulin Delivery in Elderly With Type 1 Diabetes (AIDE T1D)
|
Phase 4 | |
Completed |
NCT02527265 -
Afrezza Safety and Pharmacokinetics Study in Pediatric Patients
|
Phase 2 | |
Completed |
NCT03738865 -
G-Pen Compared to Glucagen Hypokit for Severe Hypoglycemia Rescue in Adults With Type 1 Diabetes
|
Phase 3 | |
Completed |
NCT03240432 -
Wireless Innovation for Seniors With Diabetes Mellitus
|
N/A | |
Completed |
NCT03168867 -
Effectiveness Trial of an E-Health Intervention To Support Diabetes Care in Minority Youth (3Ms)
|
N/A | |
Completed |
NCT03674281 -
The VRIF Trial: Hypoglycemia Reduction With Automated-Insulin Delivery System
|
N/A | |
Completed |
NCT03669770 -
Ultrasound Classification and Grading of Lipohypertrophy and Its Impact on Glucose Variability in Type 1 Diabetes
|
||
Recruiting |
NCT03682640 -
Azithromycin Insulin Diet Intervention Trial in Type 1 Diabetes
|
Phase 2 | |
Recruiting |
NCT04096794 -
Chinese Alliance for Type 1 Diabetes Multi-center Collaborative Research
|
||
Completed |
NCT02882737 -
The Impact of Subcutaneous Glucagon Before, During and After Exercise a Study in Patients With Type 1 Diabetes Mellitus
|
N/A | |
Recruiting |
NCT02745808 -
Injectable Collagen Scaffold™ Combined With HUC-MSCs for the Improvement of Erectile Function in Men With Diabetes
|
Phase 1 | |
Completed |
NCT02562313 -
A Trial Investigating the Continuous Subcutaneous Insulin Infusion of a Liquid Formulation of BioChaperone Insulin Lispro in Comparison to Humalog®
|
Phase 1 | |
Withdrawn |
NCT02518022 -
How to be Safe With Alcoholic Drinks in Diabetes
|
N/A | |
Completed |
NCT02558491 -
Feasibility of a Decision Support System to Reduce Glucose Variability in Subject With T1DM
|
N/A | |
Completed |
NCT02596204 -
Diabetes Care Transformation: Diabetes Data Registry and Intensive Remote Monitoring
|
N/A |