Type 1 Diabetes Mellitus Clinical Trial
— SMA002Official title:
A Clinical Study of the Warm-Up, Accuracy, and Lag Performance of a Glucose Blinding Protein-Based Continuous Glucose Monitor (GBP CGM)
The purpose of this study is to assess the accuracy of the Becton Dickenson (BD)
Technologies Glucose Binding Protein-Based Continuous Glucose Monitor (GBP CGM) in patients
with Type 1 diabetes during low (goal glucose 55 mg/dL), normal (80-140 mg/dL) and high
(>180mg/dL) glucose levels over a 24 hour period. This will be achieved by monitoring blood
sugar levels when a regular dinner meal is given, when a liquid breakfast meal (BOOST
Original containing 41 grams Carbohydrates (CHO), 4 grams fat, 10 grams protein) is given,
when subcutaneous insulin is dosed to induce hypoglycemia to a goal of 55 mg/dL, and when a
regular lunch meal is given. A Continuous Glucose Monitor (CGM) is an electronic device that
measures and displays blood sugar (glucose) levels in the body throughout the day and night.
The method being used to detect blood sugar in the investigational Glucose Binding
Protein-Based Continuous Glucose Monitor (GBP CGM) is different than the method that is
currently in use by commercially available models.
Some sensors cannot tell the difference between glucose (sugar) and other substances such as
Tylenol, aspirin or citric acid etc. Because they cannot tell the difference, they may give
false readings. The GBP CGM is made to only recognize glucose in the body rather than other
substances (e.g., Tylenol, aspirin, citric acid, etc.). As a result, the investigators
expect the new GBP CGM to be more accurate at detecting low blood sugar levels than the
current devices.
Status | Completed |
Enrollment | 16 |
Est. completion date | July 2012 |
Est. primary completion date | July 2012 |
Accepts healthy volunteers | No |
Gender | Both |
Age group | 21 Years to 65 Years |
Eligibility |
Inclusion Criteria: - Clinical diagnosis of type 1 diabetes mellitus for =1 year. For an individual to be enrolled at least one criterion from each list must be met. - Criteria for documented hyperglycemia (at least 1 must be met): 1. Fasting glucose =126 mg/dL - confirmed 2. Two-hour oral Glucose Tolerance Tests (OGTT) glucose =200 mg/dL - confirmed 3. HbA1c =6.5% documented - confirmed 4. Random glucose =200 mg/dL with symptoms 5. No data at diagnosis is available but the participant has a convincing history of hyperglycemia consistent with diabetes - Criteria for requiring insulin at diagnosis (1 must be met): 1. Participant required insulin at diagnosis and continually thereafter 2. Participant did not start insulin at diagnosis but upon investigator review likely needed insulin (significant hyperglycemia that did not respond to oral agents) and did require insulin eventually and used continually 3. Participant did not start insulin at diagnosis but continued to be hyperglycemic, had positive islet cell antibodies - consistent with latent autoimmune diabetes in adults (LADA) and did require insulin eventually and used continually - Use of an insulin pump to treat his or her diabetes for at least six months prior to the study. - Actively using a bolus calculator function with the current insulin pump with pre-defined parameters for glucose goal(s), carbohydrate ratio(s), and insulin sensitivity factor(s). - Signed informed consent - Age =21 and <65 years old - Body mass index between 19 and 30 kg/m2, inclusive - HbA1c =11% Exclusion Criteria: - Uncontrolled arterial hypertension (diastolic blood pressure >90 mm Hg and/or systolic blood pressure >160 mm Hg) - Impaired hepatic function measured as alanine aminotransferase or aspartate aminotransferase =three times the upper reference limit - Impaired renal function measured as creatinine >1.2 times above the upper limit of normal - Diabetic ketoacidosis in the past 6 months - Severe hypoglycemia resulting in a seizure or loss of consciousness in the 12 months prior to enrollment - Conditions which may increase the risk of induced hypoglycemia such as known coronary artery disease, congestive heart failure, history of any cardiac disorder or arrhythmia, history of a cerebrovascular event, history of migraines, seizure disorder, syncope, adrenal insufficiency, or neurological disease. - Current use of medications containing >4000 mg acetaminophen per day. - Current use of L-Monoamine oxidases (MAO) inhibitors. - Known microvascular (diabetic) complications (other than diabetic non-proliferative retinopathy),such as history of laser coagulation, proliferative diabetic retinopathy, known diabetic nephropathy (other than microalbuminuria with normal creatinine) or neuropathy requiring treatment - Known allergy to eggs - Pregnancy, breast-feeding or intention of becoming pregnant - Current or recent alcohol or drug abuse by patient history. |
Endpoint Classification: Safety/Efficacy Study, Intervention Model: Single Group Assignment, Masking: Open Label, Primary Purpose: Supportive Care
Country | Name | City | State |
---|---|---|---|
United States | University of Virginia | Charlottesville | Virginia |
Lead Sponsor | Collaborator |
---|---|
University of Virginia | Becton, Dickinson and Company, Juvenile Diabetes Research Foundation |
United States,
Type | Measure | Description | Time frame | Safety issue |
---|---|---|---|---|
Primary | Absolute Relative Difference (ARD) | ARD=100*(G_sensor-G_reference)/G_reference Calculated for when patient's G_ref was Normal (70-180 mg/dl), Hyperglycemic (>180 mg/dl) and Hypoglycemic (<70 mg/dl) The study data includes 208 paired sensor-YSI plasma glucose readings (G_reference) for each GBP CGM sensor (G_sensor) inserted for 24 hours during hyperglycemic and hypoglycemic challenge conditions. Data pairs will permit the detailed evaluation of sensor performance parameters, including static accuracy metrics such as median and mean absolute deviations and median and mean absolute relative deviation and Point CG-EGA, as well as dynamic parameters, such as warm-up time, trend accuracy (Rate CG-EGA), and sensor lag. |
25.5 hours | No |
Status | Clinical Trial | Phase | |
---|---|---|---|
Completed |
NCT04476472 -
Omnipod Horizon™ Automated Glucose Control System Preschool Cohort
|
N/A | |
Completed |
NCT03635437 -
Evaluation of Safety and Diabetes Status Upon Oral Treatment With GABA in Patients With Longstanding Type-1 Diabetes
|
Phase 1/Phase 2 | |
Completed |
NCT04909580 -
Decision Coaching for Youth and Parents Considering Insulin Delivery Methods for Type 1 Diabetes
|
N/A | |
Active, not recruiting |
NCT00679042 -
Islet Transplantation in Type 1 Diabetic Patients Using the University of Illinois at Chicago (UIC) Protocol
|
Phase 3 | |
Completed |
NCT03293082 -
Preschool CGM Use and Glucose Variability in Type 1 Diabetes
|
N/A | |
Completed |
NCT04016662 -
Automated Insulin Delivery in Elderly With Type 1 Diabetes (AIDE T1D)
|
Phase 4 | |
Completed |
NCT02527265 -
Afrezza Safety and Pharmacokinetics Study in Pediatric Patients
|
Phase 2 | |
Completed |
NCT03738865 -
G-Pen Compared to Glucagen Hypokit for Severe Hypoglycemia Rescue in Adults With Type 1 Diabetes
|
Phase 3 | |
Completed |
NCT03240432 -
Wireless Innovation for Seniors With Diabetes Mellitus
|
N/A | |
Completed |
NCT03168867 -
Effectiveness Trial of an E-Health Intervention To Support Diabetes Care in Minority Youth (3Ms)
|
N/A | |
Completed |
NCT03674281 -
The VRIF Trial: Hypoglycemia Reduction With Automated-Insulin Delivery System
|
N/A | |
Completed |
NCT03669770 -
Ultrasound Classification and Grading of Lipohypertrophy and Its Impact on Glucose Variability in Type 1 Diabetes
|
||
Recruiting |
NCT03682640 -
Azithromycin Insulin Diet Intervention Trial in Type 1 Diabetes
|
Phase 2 | |
Recruiting |
NCT04096794 -
Chinese Alliance for Type 1 Diabetes Multi-center Collaborative Research
|
||
Completed |
NCT02882737 -
The Impact of Subcutaneous Glucagon Before, During and After Exercise a Study in Patients With Type 1 Diabetes Mellitus
|
N/A | |
Recruiting |
NCT02745808 -
Injectable Collagen Scaffold™ Combined With HUC-MSCs for the Improvement of Erectile Function in Men With Diabetes
|
Phase 1 | |
Completed |
NCT02562313 -
A Trial Investigating the Continuous Subcutaneous Insulin Infusion of a Liquid Formulation of BioChaperone Insulin Lispro in Comparison to Humalog®
|
Phase 1 | |
Withdrawn |
NCT02518022 -
How to be Safe With Alcoholic Drinks in Diabetes
|
N/A | |
Withdrawn |
NCT02579148 -
Collagen Scaffolds Loaded With HUCMSCs for the Improvement of Erectile Function in Men With Diabetes
|
Phase 1 | |
Completed |
NCT02596204 -
Diabetes Care Transformation: Diabetes Data Registry and Intensive Remote Monitoring
|
N/A |