Study information

Verified date December 2023
Source Children's Hospital of Philadelphia
Contact Aaron E Chen, MD
Phone 2674260383
Email chena2@chop.edu
Is FDA regulated No
Health authority
Study type Interventional

Clinical Trial Summary

Children with blunt abdominal trauma often get a CT as the first line imaging to evaluate for intra-abdominal organ injury. CT scans have some downsides with regard to radiation exposure, costs, and need for transport. Contrast enhanced ultrasonography has recently shown some promise as a way to detect intra-abdominal organ injury and may be able to replace the need for conventional CT scanning, without the need for ionizing radiation and the ability to be performed at the bedside.


Description:

In children with abdominal trauma, computed tomography (CT) of the abdomen is considered the gold standard for the initial evaluation of solid organ injuries. The major drawbacks to CT include risks due to radiation exposure and necessity of transport of the patient. Ultrasound without contrast uses safer non-ionizing radiation and can be performed at the bedside, however it has been shown to have variable sensitivity and specificity for identifying intra-abdominal organ injury. Newer studies using contrast enhanced ultrasound (CEUS) have shown promise for improving the sensitivity and specificity of this imaging modality. Hypothesis(es) and Aims: Hypothesis: Contrast enhanced ultrasound (CEUS) has good sensitivity and specificity as compared to a gold standard conventional CT scan for the identification of intra-abdominal solid organ injury in hemodynamically stable children with blunt abdominal trauma. Specific Aims: Primary Aim: To determine the test characteristics CEUS / conventional ultrasound for the detection of intra-abdominal solid organ injury, as compared to a gold standard CT scan, in hemodynamically stable children with blunt abdominal trauma Design: This will be a prospective cohort study to evaluate the test characteristics of contrast enhanced ultrasound (CEUS) for the detection of intra-abdominal solid organ injury in children with blunt abdominal trauma, as compared to a gold standard CT scan. Study subjects will be age 0-18 years, presenting with hemodynamically stable blunt abdominal trauma and for whom an abdominal CT scan is planned. The exclusion criteria will be a known allergy to the ultrasound contrast agent, co-existing penetrating abdominal trauma, or known congenital or acquired heart disease. Sample size calculations assume a baseline prevalence of disease in approximately 20% of patients receiving a CT scan, and target a sensitivity of at least 95% with a two-sided confidence interval precision of 8%, yielding an estimated sample size of 146 patients. The primary outcome will be calculation of sensitivity and specificity of CEUS as compared to a gold standard CT scan.


Recruitment information / eligibility

Status Recruiting
Enrollment 146
Est. completion date December 31, 2024
Est. primary completion date December 31, 2024
Accepts healthy volunteers No
Gender All
Age group 0 Years to 17 Years
Eligibility Inclusion Criteria: 1. Hemodynamically stable (defined as not needing massive transfusion protocol and not undergoing an emergent surgical procedure within the next hour) 2. History of or suspicion for blunt abdominal trauma 3. Abdominal CT ordered or obtained Exclusion Criteria: 1. History of allergic reaction to Lumason, sulfur hexaflouride, sulfur hexafluoride lipid microsphere components, or other ingredients in Lumason (polyethylene glycol, distearoylphosphatidylcholine (DSPC), dipalmitoylphosphatidylglycerol sodium (DPPG-Na), palmitic acid) 2. Co-existing penetrating abdominal trauma 3. Known congenital or acquired heart disease

Study Design


Related Conditions & MeSH terms


Intervention

Drug:
Sulfur Hexafluoride Lipid Type A Microspheres 25 MG Intravenous Powder for Suspension [LUMASON]
injection of Lumason (ultrasound contrast agent)
Device:
contrast-enhanced ultrasound
ultrasound of the abdomen after injection of ultrasound contrast agent (Lumason)

Locations

Country Name City State
United States Children's Hospital of Philadelphia Philadelphia Pennsylvania

Sponsors (1)

Lead Sponsor Collaborator
Children's Hospital of Philadelphia

Country where clinical trial is conducted

United States, 

References & Publications (16)

Afaq A, Harvey C, Aldin Z, Leen E, Cosgrove D. Contrast-enhanced ultrasound in abdominal trauma. Eur J Emerg Med. 2012 Jun;19(3):140-5. doi: 10.1097/MEJ.0b013e328348c980. — View Citation

Armstrong LB, Mooney DP, Paltiel H, Barnewolt C, Dionigi B, Arbuthnot M, Onwubiko C, Connolly SA, Jarrett DY, Zalieckas JM. Contrast enhanced ultrasound for the evaluation of blunt pediatric abdominal trauma. J Pediatr Surg. 2018 Mar;53(3):548-552. doi: 10.1016/j.jpedsurg.2017.03.042. Epub 2017 Mar 20. — View Citation

Bixby SD, Callahan MJ, Taylor GA. Imaging in pediatric blunt abdominal trauma. Semin Roentgenol. 2008 Jan;43(1):72-82. doi: 10.1053/j.ro.2007.08.009. No abstract available. — View Citation

Cagini L, Gravante S, Malaspina CM, Cesarano E, Giganti M, Rebonato A, Fonio P, Scialpi M. Contrast enhanced ultrasound (CEUS) in blunt abdominal trauma. Crit Ultrasound J. 2013 Jul 15;5 Suppl 1(Suppl 1):S9. doi: 10.1186/2036-7902-5-S1-S9. Epub 2013 Jul 15. — View Citation

Catalano O, Aiani L, Barozzi L, Bokor D, De Marchi A, Faletti C, Maggioni F, Montanari N, Orlandi PE, Siani A, Sidhu PS, Thompson PK, Valentino M, Ziosi A, Martegani A. CEUS in abdominal trauma: multi-center study. Abdom Imaging. 2009 Mar-Apr;34(2):225-34. doi: 10.1007/s00261-008-9452-0. — View Citation

Clevert DA, Weckbach S, Minaifar N, Clevert DA, Stickel M, Reiser M. Contrast-enhanced ultrasound versus MS-CT in blunt abdominal trauma. Clin Hemorheol Microcirc. 2008;39(1-4):155-69. — View Citation

Cokkinos D, Antypa E, Stefanidis K, Tserotas P, Kostaras V, Parlamenti A, Tavernaraki K, Piperopoulos PN. Contrast-enhanced ultrasound for imaging blunt abdominal trauma - indications, description of the technique and imaging review. Ultraschall Med. 2012 Feb;33(1):60-7. doi: 10.1055/s-0031-1273442. Epub 2012 Jan 24. — View Citation

Darge K, Papadopoulou F, Ntoulia A, Bulas DI, Coley BD, Fordham LA, Paltiel HJ, McCarville B, Volberg FM, Cosgrove DO, Goldberg BB, Wilson SR, Feinstein SB. Safety of contrast-enhanced ultrasound in children for non-cardiac applications: a review by the Society for Pediatric Radiology (SPR) and the International Contrast Ultrasound Society (ICUS). Pediatr Radiol. 2013 Sep;43(9):1063-73. doi: 10.1007/s00247-013-2746-6. Epub 2013 Jul 11. — View Citation

Menichini G, Sessa B, Trinci M, Galluzzo M, Miele V. Accuracy of contrast-enhanced ultrasound (CEUS) in the identification and characterization of traumatic solid organ lesions in children: a retrospective comparison with baseline US and CE-MDCT. Radiol Med. 2015 Nov;120(11):989-1001. doi: 10.1007/s11547-015-0535-z. Epub 2015 Mar 31. — View Citation

Miele V, Piccolo CL, Galluzzo M, Ianniello S, Sessa B, Trinci M. Contrast-enhanced ultrasound (CEUS) in blunt abdominal trauma. Br J Radiol. 2016;89(1061):20150823. doi: 10.1259/bjr.20150823. Epub 2016 Jan 8. — View Citation

Ntoulia A, Anupindi SA, Darge K, Back SJ. Applications of contrast-enhanced ultrasound in the pediatric abdomen. Abdom Radiol (NY). 2018 Apr;43(4):948-959. doi: 10.1007/s00261-017-1315-0. — View Citation

Parker JM, Weller MW, Feinstein LM, Adams RJ, Main ML, Grayburn PA, Cosgrove DO, Goldberg BA, Darge K, Nihoyannopoulos P, Wilson S, Monaghan M, Piscaglia F, Fowlkes B, Mathias W, Moriyasu F, Chammas MC, Greenbaum L, Feinstein SB. Safety of ultrasound contrast agents in patients with known or suspected cardiac shunts. Am J Cardiol. 2013 Oct 1;112(7):1039-45. doi: 10.1016/j.amjcard.2013.05.042. Epub 2013 Jun 28. — View Citation

Sivit CJ. Imaging children with abdominal trauma. AJR Am J Roentgenol. 2009 May;192(5):1179-89. doi: 10.2214/AJR.08.2163. — View Citation

Valentino M, Ansaloni L, Catena F, Pavlica P, Pinna AD, Barozzi L. Contrast-enhanced ultrasonography in blunt abdominal trauma: considerations after 5 years of experience. Radiol Med. 2009 Oct;114(7):1080-93. doi: 10.1007/s11547-009-0444-0. Epub 2009 Sep 22. — View Citation

Valentino M, De Luca C, Galloni SS, Branchini M, Modolon C, Pavlica P, Barozzi L. Contrast-enhanced US evaluation in patients with blunt abdominal trauma(). J Ultrasound. 2010 Mar;13(1):22-7. doi: 10.1016/j.jus.2010.06.002. Epub 2010 Jul 8. — View Citation

Valentino M, Serra C, Pavlica P, Labate AM, Lima M, Baroncini S, Barozzi L. Blunt abdominal trauma: diagnostic performance of contrast-enhanced US in children--initial experience. Radiology. 2008 Mar;246(3):903-9. doi: 10.1148/radiol.2463070652. Epub 2008 Jan 14. — View Citation

* Note: There are 16 references in allClick here to view all references

Outcome

Type Measure Description Time frame Safety issue
Primary Sensitivity of CEUS calculation of sensitivity of CEUS for organ injury, as compared to gold standard CT through study completion, which is expected to take around 3 years
Primary Specificity of CEUS calculation of specificity of CEUS for organ injury, as compared to gold standard CT exam through study completion, which is expected to take around 3 years
See also
  Status Clinical Trial Phase
Completed NCT04934384 - The Role of Prehospital eFAST in Accelerating Time to Diagnostics or Definitive Treatment in the Emergency Department
Recruiting NCT05288985 - Impact of Loco-regional Analgesia Following Placement of Erector Spinae Plane Catheter in Addition to Systemic Analgesia in Patients With Thoracic Trauma N/A
Not yet recruiting NCT06043414 - Barbed Suture vs Non-Barbed Closure for Emergency Exploratory Laparotomy RCT N/A
Completed NCT03466684 - BIA Guided-fluid Management in Postinjury Open Abdomen N/A
Recruiting NCT05208489 - Direct Peritoneal Resuscitation for Intra-abdominal Catastrophes