Clinical Trials Logo

Clinical Trial Summary

Radiation therapy, total skin electron therapy (TSET), achieves a high response rate and is an effective treatment for cutaneous T-cell lymphoma affecting the superficial region 1. One the most widely used TSET techniques consists of six dual fields initially developed at Stanford University 2. Dosimetrically, TSET at energies of about 3-7 MeV at the surface of a standing patient may result in significant dose variations due to variable skin distance, self shielding, irradiated fields overlapping and patient motion. Deviations occur from the prescription dose up to 40% and the surface dose inhomogeneity as much as 90% in body areas such as the perineum and eyelid, are revealed in the literature. To improve this condition, a selection of patients with advanced skin disease and regional extension could be cured by a combination of TSEB and photon beam irradiation.

Helical tomotherapy (HT) has advantages in irradiating extended volumes with treatment length of up to 160 cm, continuously in a helical pattern without the need for field junction. Total marrow irradiation (TMI) via HT with low toxicities for bone marrow transplantation of Asia multiple myeloma patients could be feasible . A study of HT for total scalp irradiation has also shown that the employment of directional and complete blocking on the inner structures can effectively force the tangential delivery of the majority of beamlets to the PTV, which can limit the treatment depth.

Using HT, an image-guided intensity-modulated radiotherapy, to replace conventional TSI technique to increase dose delivery and decrease toxicities could be a workable and feasible. Here, we applied TSI via HT (HITS) for a woman with T cell lymphoma failure by chemotherapy, topic UV irradiation and local radiotherapy (RT) in MMH to overcome the surface dose inhomogeneity by conventional RT. Additionally, we will compare the advantages and disadvantages between the plan of HT and conventional RT for TSI.


Clinical Trial Description

Helical tomotherapy planning

Patient will dress the diving suit (3 mm thick) to create bolus effect. AccuFix™ Cantilever Board™ with shoulder depression and thermoplastic fixation were used for head and shoulder immobilization. BlueBagTM immobilization system (Medical Intelligence) was used to fix main trunk and extremities. Both immobilization systems provide a consistent treatment position from the initial computed tomography (CT) scanning, pretreatment megavoltage CT (MVCT) imaging to final treatment delivery. For tomotherapy treatment planning, a CT image set of the whole body was required. The patients were scanned in a large bore (75 cm) CT scanner (Siemens, SOMATOM Definition, Dual source computed tomography system). Because most critical organs are located in the central part of the body, therefore two image sets were scanned with 2.5 mm and 5 mm for upper and lower part, respectively. The level at 15 cm above knee was used as a reference point to separate the upper and lower set. The geometric edges of both fields were abutted at the HT treatment's 50% isodose plane.

Both image sets were restored on a Pinnacle workstation using the Pinnacle Launch Pad Restore utility then using the Philips Pinnacle3 treatment planning system for contouring because the HT planning system has no such capability. After that, the plan was transferred to the Tomotherapy Hi Art Planning system (Tomotherapy, Inc., Madison, Wisconsin, USA). The clinical target volume (CTV) included the entire body surface system with subcutaneous 0.5 cm. To account for set-up variability and breathing motion, a planning target volume (PTV) was generated with a 0.5 cm margin The prescription dose was 75 cGy/fraction in 4 times/wk for total skin area and for tumor area. Total doses of 30 Gy to 95% of the PTV are delivered to the total skin area and tumor part, respectively. The normal tissue dose constraints utilized were based on the results of the survey of the clinical outcome of the target dose and dose limits to various organs at risk (OARs) such as the brain, optic chiasm, optic nerves, lenses, eyes, parotid glands, oral cavity, thyroid gland, bilateral lungs, esophagus, heart, liver, spleen, pancreases, kidneys, bowel, bladder, uterus and vagina. Maximum importance was given to target dose coverage. The constraints on dose and penalty were adjusted accordingly during optimization. The field width, pitch, and modulation factor (MF) used for the treatment planning optimization were 2.5, 0.287 cm, and 3.5, respectively. The dose volume histograms (DVHs) were calculated for the target and individual OARs. Toxicity of treatment was scored according to the Common Terminology Criteria for Adverse Events v4.0 (CTCAE v4.0).

Image guidance:

Daily check of patient positioning was performed by the MVCT system integrated in the tomotherapy machine. Briefly, before every treatment, MVCT scans were taken in selected regions using the normal mode (4 mm slice thickness) of the body and fused with the treatment planning CT scan using bony anatomy and soft tissue images such as the lungs. Three sets of MVCT scan (scan 1, orbits to T4; scan 2, T10 to the ischial tuberosities; scan 3, 15 cm above knee to 15 cm below knee) were performed to the check the patient's whole body alignment. MVCT scans were obtained. Image fusions were evaluated by the attending physician and physicist. Any translational shifts suggested by the image fusion results were applied to the final patient setup before treatment delivery. The tolerance of setup error allowed only a 5-mm difference between the three scans in any of the three translation directions and 1° of difference in roll. Additional selected MVCT scans were performed after treatment to verify patient immobilization. ;


Study Design

Observational Model: Case-Only, Time Perspective: Retrospective


Related Conditions & MeSH terms


NCT number NCT01854112
Study type Observational
Source Far Eastern Memorial Hospital
Contact
Status Enrolling by invitation
Phase N/A
Start date November 2012

See also
  Status Clinical Trial Phase
Completed NCT00959686 - Bendamustine in Patients With Refractory or Relapsed T-cell Lymphoma Phase 2
Active, not recruiting NCT04712864 - Study of CD4-Targeted Chimeric Antigen Receptor T-Cells (CD4- CAR-T) in Subjects With Relapsed or Refractory T-Cell Lymphoma Phase 1
Recruiting NCT05665530 - A Study of PRT2527 as Monotherapy and in Combination With Zanubrutinib in Participants With R/R Hematologic Malignancies Phase 1
Completed NCT01941680 - High Risk Adult T-cell Leukemia/Lymphoma (ATLL-HR) and Allogeneic Transplant
Recruiting NCT05075460 - Tucidinostat, Azacitidine Combined With CHOP Versus CHOP in Patients With Untreated Peripheral T-cell Lymphoma Phase 3
Completed NCT03734601 - Total Body Irradiation +/- Total Lymphoid Irradiation & Anti-Thymocyte Globulin in Non-myeloablative Hematopoietic Cell Transplantation Phase 2
Completed NCT02017613 - Safety and Efficacy Study of a Dual PI3K Delta/Gamma Inhibitor in Hematological Malignancies Phase 1
Completed NCT01553786 - Efficacy of a Treatment With CHOP and Lenalidomide in First Line in Angioimmunoblastic T-cell Lymphoma (AITL) Phase 2
Completed NCT00542919 - A Study for Patients With Non-Hodgkin's Lymphomas Phase 2
Recruiting NCT06131801 - Pharmacokinetic Study of Venetoclax Tablets Crushed and Dissolved Into a Solution
Active, not recruiting NCT03952078 - A Dose Escalation Study Evaluating CPI-818 in Relapsed/Refractory T-Cell Lymphoma Phase 1
Not yet recruiting NCT05983965 - Study of Tazemetostat in Lymphoid Malignancies Phase 1
Not yet recruiting NCT06390319 - Adding Dasatinib Or Venetoclax To Improve Responses In Children With Newly Diagnosed T-Cell Acute Lymphoblastic Leukemia (ALL) Or Lymphoma (T-LLY) Or Mixed Phenotype Acute Leukemia (MPAL) Phase 2
Not yet recruiting NCT05387226 - Intravenous Injection of Oncolytic Virus Injection (RT-01) in Patients With Relapsed or Refractory T-cell Lymphoma Phase 1
Completed NCT02424045 - Bendamustine, Carboplatin and Dexamethasone (BCD) for Refractory or Relapsed Peripheral T-cell Lymphoma Phase 2
Completed NCT01871675 - Study of IPI-145 in Combination With Rituximab or Bendamustine/Rituximab in Hematologic Malignancies Phase 1
Terminated NCT00893516 - CD4 in Combination With CHOP in Treating Non-cutaneous Peripheral TCell Lymphoma Phase 2
Completed NCT01902225 - Phase I Dose-finding and Preliminary Efficacy Study of the Istodax® in Combination With Doxil® for the Treatment of Adults With Relapsed or Refractory Cutaneous T-cell Lymphoma Phase 1
Recruiting NCT02086591 - A Phase II Study of Doxycycline in Relapsed NHL Phase 2
Recruiting NCT04264078 - Anti-CD7 U-CAR-T Cell Therapy for T/NK Cell Hematologic Malignancies Early Phase 1