Clinical Trials Logo

Clinical Trial Summary

Insertable Cardiac Monitor's (ICM's) such as Confirm Rx™ are leadless devices implanted for long-term heart rhythm monitoring in the diagnosis and management of clinical conditions such as recurrent unexplained syncope, cryptogenic stroke, ventricular arrhythmias and monitoring atrial fibrillations (AF) post ablation. There is limited data on variations seen in signal sensing with changes in physical activity and posture. This single arm, non-randomized, open-label, multi-center, clinical investigation of 100 subjects is designed to characterise the safety and performance of Confirm RxTM by assessing quality of signal attained from the device with changes in posture and physical activity at implant and 30days post procedure. The study is also intended to assess gross migrations of the device at 30days post implant.


Clinical Trial Description

Syncope is a condition that has vexed cardiologists worldwide due to its elusive nature. Often a third of patients with syncope remain undiagnosed despite assessments by multidisciplinary teams and the availability of various screening techniques such as electrocardiography, 24-h Holter monitoring, carotid sinus massage, echocardiography, exercise testing, head-up tilt test, and electrophysiological studies. Recently, ICM's have been developed to continuously monitor heart rhythm and thus aid in the diagnoses and management of clinical conditions such as ventricular arrhythmias, cryptogenic stroke, recurrent unexplained syncope and for monitoring atrial fibrillations (AF) post ablation. ICM's such as Confirm Rx from Abbott are leadless devices that detect arrhythmias largely depending on sensing of changes in R-R interval and R wave amplitude in the ECG signal. Whilst ICM's have been helpful in detecting arrhythmias in up to 40% of these patients with unexplained syncope, there is paucity of data regarding changes in signal quality with variations in body posture, physical activity and device movements that could potentially have effects on ECG signal and thus event detection. To this extent, this is an Abbott sponsored prospective, single arm, non-randomized, open-label, multi-center, clinical trial of 100 subjects designed to characterize the safety and performance of Confirm Rx™ in relation to physical activity and posture in these subjects with unexplained syncope. ConfirmRx™ has come a long way since its inception with a significant reduction in size (78% reduction by volume) that has led to relatively simple insertion procedures through a small skin incision. The less complicated insertion process permits the insertion procedure to take place in settings besides operating rooms and furthermore, smaller devices are associated with significantly lower incidence of infections. We believe that this study will add to growing body of evidence of the efficacy of ConfirmRx. The primary objective of this clinical investigation is to characterise the safety and performance of the Confirm Rx™ Insertable Cardiac Monitor (ICM) by assessing quality of signal attained from device post implant with changes in posture and physical activity at implant and 30days post procedure. Primary Endpoints - Changes in R-wave amplitudes at time of insertion and 30 days post-insertion. - Changes in R-wave amplitude with below defined movements at time of insertion, and 30days post-insertion. To identify any gross migration of Confirm Rx device 30 days following implant. Secondary Endpoints - Change in measured distance/position of scar relative to distance from left lateral sternal border at baseline and 30 days - Measurement of tip of device from left lateral sternal border - Deviation of proximal tip of device from scar compared to baseline ;


Study Design


Related Conditions & MeSH terms


NCT number NCT03803969
Study type Interventional
Source Abbott Medical Devices
Contact Sinny Delacroix, MD, PhD
Phone 61 8 8202 6651
Email sinny.delacroix@abbott.com
Status Recruiting
Phase N/A
Start date October 30, 2018
Completion date October 30, 2024

See also
  Status Clinical Trial Phase
Completed NCT06038708 - Head-up Tilt Test in Patients With Reflex Syncope and Asystolic Response Who Received a Dual-chamber Pacemaker With the Closed Loop Stimulation (CLS) and Participated in the BIOSync Trial
Completed NCT00069693 - Evaluation of Chronic Orthostatic Intolerance N/A
Not yet recruiting NCT05649891 - Checklists Resuscitation Emergency Department N/A
Completed NCT02565238 - BIO.MASTER.BioMonitor 2 Study N/A
Active, not recruiting NCT01965899 - Usability Study to Assess the Reveal LINQ Insertable Cardiac Monitor System N/A
Completed NCT00746564 - Study of New Implantable Loop Recorder N/A
Completed NCT00359203 - ISSUE3: International Study on Syncope of Uncertain Etiology 3 Phase 4
Recruiting NCT04972071 - SW-RCT Implementation of Canadian Syncope Risk Score Based Practice Recommendations N/A
Completed NCT04198220 - BIO|STREAM.ICM Obesity
Recruiting NCT04533425 - Practical Approaches to Care in Emergency Syncope
Completed NCT05571254 - The Management of Transient Loss of Consciousness and Suspected Syncope in European Emergency Departments
Recruiting NCT05621460 - The Effect of Water Carbonation on Orthostatic Tolerance N/A
Not yet recruiting NCT05957315 - Mobile Cardiac Outpatient Telemetry for Unexplained Syncope N/A
Recruiting NCT04615065 - Acutelines: a Large Data-/Biobank of Acute and Emergency Medicine
Completed NCT05729724 - Effect of Pharmacological Interventions on Systolic Blood Pressure Drops (SynABPM 2 Proof-of-concept)
Completed NCT05782712 - Rapid Measurement of Adenosine in Syncope Patients
Completed NCT03786640 - Abbott Brady 3T MRI PMCF
Recruiting NCT05575934 - Management of Transitory Loss of Consciousness and Syncopes in the Emergency Department
Recruiting NCT04075084 - Observation of Clinical Routine Care for Patients With BIOTRONIK Implantable Cardiac Monitors (ICMs)
Completed NCT02786940 - Remote Cardiac Monitoring of Higher-Risk Emergency Department Syncope Patients After Discharge - A Pilot Study N/A